Kangning Xie

Dr. Kangning Xie


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2024 in Psychiatry Research
Verified
Journal Article
Open access
XWXianyang Wang
Xianyang Wang
MYMengyuan Yang
Mengyuan Yang
LRLei Ren
Lei Ren
QWQingyi Wang
Qingyi Wang
SLShuyi Liang
Shuyi Liang
SWShengjun Wu
Shengjun Wu
Research on burnout has garnered considerable attention since its inception. However, the ongoing debate persists regarding the conceptual model of burnout and its relationship with depression. Thus, we conducted a network analysis to determine the dimensional structure of burnout and the burnout-depression overlap. The Maslach Burnout Inventory-Student Survey and Patient Health Questionnaire-9 were used to measure burnout and depression among 1096 college students. We constructed networks for burnout, depression, and a burnout-depression co-occurrence network. The results showed that cynicism symptom was the most central to the burnout network. In the co-occurrence network, depressive symptoms ("anhedonia", "fatigue") and burnout symptom ("doubting the significance of studies") were the most significant in causing burnout-depression comorbidity. Community detection revealed three communities within burnout symptoms, aligning closely with their three dimensions identified through factor analysis. Additionally, there was no overlap between burnout and depression. In conclusion, our findings support a multidimensional structure of burnout, affirming it as a distinct concept separate from depression. Cynicism, rather than exhaustion, plays the most important role in burnout and the burnout-depression comorbidity.

26 October 2022 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
YZYawen Zhai
Yawen Zhai
YLYan Li
Yan Li
SZShengyi Zhou
Shengyi Zhou
CZChenxu Zhang
Chenxu Zhang
ELErping Luo
Erping Luo
KXKangning Xie
Kangning Xie
Mental fatigue (MF) jeopardizes performance and safety through a variety of cognitive impairments and according to the complexity loss theory, should represent “complexity loss” in electroencephalogram (EEG). However, the studies are few and inconsistent concerning the relationship between MF and loss of complexity, probably because of the susceptibility of brain waves to noise. In this study, MF was induced in thirteen male college students by a simulated flight task. Before and at the end of the task, spontaneous EEG and auditory steady-state response (ASSR) were recorded and instantaneous frequency variation (IFV) in alpha rhythm was extracted and analyzed by multiscale entropy (MSE) analysis. The results show that there were significant differences in IFV in alpha rhythm either from spontaneous EEG or from ASSR for all subjects. Therefore, the proposed method can be effective in revealing the complexity loss caused by MF in spontaneous EEG and ASSR, which may serve as a promising analyzing method to mark mild mental impairments.

1 January 2020 in IEEE Access
Verified
Journal Article
Open access
WHWei Han
Wei Han
ZZZunjing Zhang
Zunjing Zhang
CTChi Tang
Chi Tang
YYYili Yan
Yili Yan
ELErping Luo
Erping Luo
KXKangning Xie
Kangning Xie
Quantifying the complexity of physiologic time series has long attracted interest from researchers. The multiscale entropy (MSE) algorithm is a prevailing method to quantify the complexity of signals in a variety of research fields. However, the MSE method assigns increased complexity to the mixed signal of a physiologic time series added with white noise, although the mixed signal should become less complex due to the broken correlation. In addition, the MSE method needs users to visually examine its scale dependence (shape) to better characterize the complexity of a physiologic process, which is sometimes not feasible. In this paper, we proposed a new method, namely the power-law exponent modulated multiscale entropy (pMSE), as a complexity measure for physiologic time series. We tested the pMSE method on simulated data and real-world physiologic interbeat interval time series and demonstrated that it could solve the above two difficulties of the MSE method. We expect that the proposed pMSE method or its future variants could serve as a useful complement to the MSE method for the complexity analysis of physiologic time series.

13 January 2021 in IEEE Access
Verified
Journal Article
Open access
YLYan Li
Yan Li
JLJuan Liu
Juan Liu
CTChi Tang
Chi Tang
WHWei Han
Wei Han
SZShengyi Zhou
Shengyi Zhou
KXKangning Xie
Kangning Xie
Generally, for healthy adults, the entropy of electroencephalogram (EEG) signals gradually decreases from wake to sleep stages N1, N2, to N3, and increases during REM. However, some researchers found that multiscale entropy curves of sleep and wakefulness intercept, a cross-over phenomenon whose origin remains unexplored. The objective of the present work is to trace the origin of the cross-over phenomenon and to propose a workaround strategy. We simulated EEG by generating 1/f broadband signal and chirp signals with continuously varying frequencies. We then retrieved the rhythmic component from simulated EEG and real-world EEG and conducted MSE analysis of the instantaneous frequency variation (IFV) of the rhythmic component. The simulation revealed that this interception was ubiquitous in the MSE analysis of simulated EEG with rhythmic components of different frequencies. The cross-over point moved toward larger scale factors with the increasing sampling rate. We found that the MSE curve of IFV from real-world EEG for the wakefulness group was higher than that for sleep, showing no interception. These results suggest that (1) for a rhythmic signal like EEG, MSE analysis of the raw signal is highly affected by the rhythmic component, presenting artificial cross-over curves in sleep EEG study, (2) frequency variation of rhythmic components are complex signal which differs between wakefulness and sleep, in accordance with the complexity loss theory.

29 July 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
NZNan Zhang
Nan Zhang
YZYawen Zhai
Yawen Zhai
YLYan Li
Yan Li
JZJiayu Zhou
Jiayu Zhou
MZMingming Zhai
Mingming Zhai
KXKangning Xie
Kangning Xie
In the analysis of electroencephalography (EEG), entropy can be used to quantify the rate of generation of new information. Entropy has long been known to suffer from variance that arises from its calculation. From a sensor’s perspective, calculation of entropy from a period of EEG recording can be treated as physical measurement, which suffers from measurement noise. We showed the feasibility of using Kalman filtering to reduce the variance of entropy for simulated signals as well as real-world EEG recordings. In addition, we also manifested that Kalman filtering was less time-consuming than moving average, and had better performance than moving average and exponentially weighted moving average. In conclusion, we have treated entropy as a physical measure and successfully applied the conventional Kalman filtering with fixed hyperparameters. Kalman filtering is expected to be used to reduce measurement noise when continuous entropy estimation (for example anaesthesia monitoring) is essential with high accuracy and low time-consumption.

1 October 2022 in Arabian Journal of Chemistry
Verified
Journal Article
Open access
CZChenxu Zhang
Chenxu Zhang
MZMingming Zhai
Mingming Zhai
KXKangning Xie
Kangning Xie
YWYingchao Wang
Yingchao Wang
XLXiuyuan Li
Xiuyuan Li
CTChi Tang
Chi Tang