Kanya Kobayashi

Mr. Kanya Kobayashi


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2005 in Legal Medicine
Verified
Journal Article
Closed access
PDF file
HAHideki Asamura
Hideki Asamura
MIMakoto Ito
Makoto Ito
KTKayoko Takayanagi
Kayoko Takayanagi
KKKanya Kobayashi
Kanya Kobayashi
MOMasao Ota
Masao Ota
HFHirofumi Fukushima
Hirofumi Fukushima

7 December 2018 in Molecules
Verified
Journal Article
Open access
PDF file
FTFumiki Takahashi
Fumiki Takahashi
MKMasaru Kobayashi
Masaru Kobayashi
AKAtsushi Kobayashi
Atsushi Kobayashi
KKKanya Kobayashi
Kanya Kobayashi
HAHideki Asamura
Hideki Asamura
Background: A simple, sensitive, and rapid extraction method based on high-frequency (H-F) heating was developed for drug analysis in human nails. Methods: A human nail was placed in a glass tube with an extraction solvent (methanol and 0.1% formic acid; 7:3, v/v), and a ferromagnetic alloy (pyrofoil) was wrapped in a spiral around the glass tube. Then, the glass tube was placed in a Curie point pyrolyzer, and a H-F alternating voltage (600 kHz) was applied. The sample and extraction solvent were heated at the Curie temperature for 3 min. Different Curie temperatures were applied by changing the pyrofoil (160 °C, 170 °C, 220 °C, and 255 °C). Results: The caffeine in the nail was effectively and rapidly extracted into the extraction solvent with the pyrofoil at 220 °C. The peak area obtained for the caffeine using liquid chromatography mass spectrometry (LC-MS/MS) was five times that of what was obtained after conventional ultrasonic irradiation extraction. Because the extraction uses high-pressure and high-temperature conditions in a test tube, the drugs that were strongly incorporated in nails could be extracted into the solvent. The amount of caffeine extracted was independent of the size of the pieces in the sample. Conclusions: Therefore, the sensitive determination of target drugs in nails is possible with rapid (20 min, including H-F extraction for 3 min) and simple sample preparation. The developed method was applied to a nail from a patient with hypertension.

19 January 2024 in Legal Medicine
Verified
Journal Article
Open access
TOTomomi Otagiri
Tomomi Otagiri
NSNoriko Sato
Noriko Sato
TSTetsuya Shiozaki
Tetsuya Shiozaki
YHYuta Harayama
Yuta Harayama
MMMomoe Matsumoto
Momoe Matsumoto
HAHideki Asamura
Hideki Asamura
For human identification, the quality and quantity of DNA must be sufficient for amplification and analysis. When DNA extraction from bone tissues and teeth is required, the optimal skeletal elements should be selected as samples for DNA extraction because DNA yield differs among elements. Recently, some studies have reported that a high quantity of high-quality DNA can be extracted from the small cancellous bones of the hands and feet. In this study, we evaluated the effectiveness of small cancellous bones in the human identification of skeletal remains in routine forensic genetic casework. Cancellous bones [phalanges, (meta)carpal bones, and (meta)tarsal bones)] and the cortical bones (femur and petrous bones) and teeth, which have generally been recommended as samples, were collected from the same individuals that needed identifying using DNA analysis in our laboratory. The quantity of DNA from small cancellous bones tended to be higher than that from cortical bones, and the quality from the former was as high as that from the latter. This study showed that in routine forensic casework, the small cancellous bones of the hands and feet should be actively selected as samples for DNA testing.