Abdallah Azzouz

Dr. Abdallah Azzouz

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2024 in Heliyon
Verified
Journal Article
Open access
AAAbdallah Azzouz
Abdallah Azzouz
BBBillel BENGHERBIA
Billel BENGHERBIA
PWPatrice Wira
Patrice Wira
NANail Alaoui
Nail Alaoui
ASAbdelkerim Souahlia
Abdelkerim Souahlia
HHHamza Hentabeli
Hamza Hentabeli
During the recording time, electrocardiogram (ECG) signals are subject to multiple artefact noises, such as muscle activity, white Gaussian noise (WGN), baseline wander, and power line interference (PLI). Therefore, pre-processing of ECG signals is essential to eliminate these artefacts and to obtain efficient ECG features. Many approaches have been proposed for removing ECG noises, including ECG signal denoising using wavelet transform (WT). However, the effectiveness and performance of the WT technique are strongly related to the configuration of its control parameters, which are typically fine-tuned through a laborious and time-consuming series of experiments. This paper introduces a technique that combines particle swarm optimisation (PSO) with WT for ECG signal denoising. The key contribution of this research is the use of PSO to determine the optimum settings for all WT parameters for ECG signal denoising (type of wavelet basis function Φ, thresholding function β, level of decomposition L, rule for threshold selection λ, and rescaling method ρ). The efficiency of the proposed method is evaluated using the percentage root mean square difference (PRD) and the signal-to-noise ratio (SNR), employing various ECG signals available online from the MIT-BIH Arrhythmia database. Experimental results show that the proposed PSO-WT technique yields better results than state-of-the-art techniques in terms of SNR, particularly for PLI measured at 60 Hz and still acceptable at 50 Hz. For example, a denoised ECG signal resulting from the proposed technique at an SNR input of 10 dB corresponds to an SNRoutput of 27.47 dB at 60 Hz, improving the quality of the denoised ECG signal and making it more appropriate for clinical diagnosis. Furthermore, the proposed method also shows promising efficiency in the presence of WGN, making it highly relevant for IoT applications and RF transmission.

27 December 2023 in Revue d'intelligence artificielle
Verified
Journal Article
Open access
AAAbdallah Azzouz
Abdallah Azzouz
BBBillel Bengherbia
Billel Bengherbia
PWPatrice Wira
Patrice Wira
NANail Alaoui
Nail Alaoui
ASAbdelkerim Souahlia
Abdelkerim Souahlia

22 February 2026 in Journal on Advances in Signal Processing
Verified
Journal Article
Open access
PDF file
AAAbdallah Azzouz
Abdallah Azzouz
ATAbdelhafid Tobbal
Abdelhafid Tobbal
BBBillel Bengherbia
Billel Bengherbia
PWPatrice Wira
Patrice Wira
ASAbdelkerim Souahlia
Abdelkerim Souahlia
AAAbdullah K. Alanazi
Abdullah K. Alanazi
Electrocardiogram (ECG) signal analysis is fundamental for the diagnosis of cardiac disorders and the detection of arrhythmias. However, manual interpretat