Kah Leng Ho

Dr. Kah Leng Ho


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JTJulian Cheong Kiat Tay
Julian Cheong Kiat Tay
JTJannah Lee Tarranza
Jannah Lee Tarranza
SCShaw Yang Chia
Shaw Yang Chia
XPXuanming Pung
Xuanming Pung
GLGermaine Jie Min Loo
Germaine Jie Min Loo
CCChi Keong Ching
Chi Keong Ching
Regional differences in pulsed field ablation (PFA) adoption for pulmonary vein isolation (PVI) with additional posterior wall ablation (PWA) in Asia remains unknown. We hereby report our experience on the safety and efficacy of PFA in AF ablation. Consecutive AF patients who underwent PFA from September 2022 to January 2024 were included. The primary efficacy endpoint was freedom from atrial arrhythmia recurrence after a 90-day blanking period at 12 months. Safety endpoints included 30 days of all-cause death, cardiac tamponade, stroke, myocardial infarction, and heart failure hospitalization. One hundred and one (72.3% males, 79.2% pAF) patients underwent PFA for AF. Thirty-one (30.7%) had structural heart disease with mean LVEF of 57.4 ± 8.1% and CHA2DS2-VASc score of 1.4 ± 1.3. Twenty-nine (28.7%) underwent additional PWA (PVI + PWA) using PFA. PWA was acutely successful in all patients. Patients who underwent PWA were more likely to have persistent AF and require general anesthesia and electroanatomic mapping (all p < 0.05). Total PFA applications for PVI, LA dwell time, procedural time, and fluoroscopy time were similar between the PVI-only and PVI + PWA groups (all p > 0.05). The 1-year atrial arrhythmia recurrence rates were 10% for pAF and 21% for the persistent AF group. The primary efficacy endpoint was not significantly different between the PVI-only and PVI+PWA groups (12-month KM estimates 90.3% [95% CI, 83.3–97.3] and 82.8% [95% CI, 68.1–97.4], respectively). There were no complications related to PFA use. PFA can be safely, effectively, and efficiently adopted for AF ablation. Additional PWA, if pursued, had similar procedural metrics to the PVI-only strategy without increased complications.

9 July 2025 in Medicina
Verified
Journal Article
Open access
PDF file
XPXuanming Pung
Xuanming Pung
JCJoe J. L. Chua
Joe J. L. Chua
KFKhi Yung Fong
Khi Yung Fong
YCYi Yi Chua
Yi Yi Chua
GLGermaine J. M. Loo
Germaine J. M. Loo
VTVern Hsen Tan
Vern Hsen Tan
Background and Objectives: The role of biventricular pacing (BVP) is less well-established in patients with heart failure with reduced ejection fraction (HFrEF) without left bundle branch block (LBBB). Conduction system pacing (CSP) has gained significant traction and may provide a safe and more physiological alternative to BVP in these patients. A few small studies studying this question have reported conflicting results. This meta-analysis aims to compare procedural and clinical outcomes between CSP and BVP in this group. Materials and Methods: An online literature search was systematically conducted to retrieve studies comparing CSP and BVP in HFrEF patients with non-LBBB. Four studies with 461 patients were included. Results: Implant-derived paced QRS duration was significantly shorter (mean difference [MD] −19.7 ms, 95% confidence interval [CI] −36.2 to −3.3, p = 0.0355) with CSP. Echocardiographic response with significantly greater improvement in left ventricular ejection fraction (MD 5.6%, 95% CI 3.1 to 8.0, p = 0.0106) was also observed with CSP. There were no statistically significant differences in clinical outcomes such as all-cause mortality (relative risk [RR] 0.53, 95% CI 0.18 to 1.60, p = 0.133) and heart failure hospitalization (RR 0.54, 95% CI 0.19 to 1.56, p = 0.129). Conclusions: This meta-analysis suggests that CSP may have better electrical synchrony and echocardiographic response compared to BVP in HFrEF patients with non-LBBB. Further randomized studies with longer follow-up may be required to elucidate potential benefits in clinical outcomes.

Verified
Journal Article
Open access
PDF file
HTHooi Khee Teo
Hooi Khee Teo
YCYi Yi Chua
Yi Yi Chua
JTJulian Cheong Kiat Tay
Julian Cheong Kiat Tay
XPXuanming Pung
Xuanming Pung
WOWei Sheng Jonathan Ong
Wei Sheng Jonathan Ong
CCChi Keong Ching
Chi Keong Ching
Conduction system pacing started with His bundle pacing (HBP) and then rapidly switched gears into left bundle branch pacing (LBBP). We describe our center’s experience with LBBP using either lumenless leads (LLLs) or stylet-driven leads (SDLs). Patients who were admitted to two tertiary centers between 1 April 2021 and 30 June 2024 and met the guidelines for pacing were recruited and prospectively followed up. A total of 124 patients underwent permanent pacemaker (PPM) implantation using the LBBP technique with a mean follow-up of 19.7 ± 13.3 months. In total, 90 patients were implanted with LLLs and 34 with SDLs. There was no significant difference in the procedural time and final paced QRS duration, but fluoroscopy time was significantly longer in the SDLs (26.2 ± 17.7 min vs. 17.5 ± 13.0 min, respectively, p = 0.026). The on-table impedance values were also significantly higher in the LLLs, and this persisted throughout the follow-up. There were no differences in the rates of complications. The success of conduction system pacing implantation with SDLs and LLLs is comparable with reasonable safety and reliable outcomes. Good pre-implant patient selection will contribute to improved outcomes.