With the increasing penetration of wind power, the transient synchronization stability of doubly fed induction generator (DFIG)-based wind turbines during grid faults has become a critical issue. While conventional fault ride-through methods like Crowbar protection can ensure safety, they compromise system controllability and worsen grid voltage conditions. Virtual resistance demagnetization control has emerged as a promising alternative due to its simple structure and effective flux damping. However, its impact on transient synchronization stability has not been revealed in existing studies. To fill this gap, this paper presents a comprehensive analysis of the transient synchronization stability of DFIG systems under virtual resistance control, introducing a novel fourth-order transient synchronization model that explicitly captures the coupling between the virtual resistance demagnetization control and phase-locked loop (PLL) dynamics. The model reveals the emergence of transient power and positive damping terms induced by the virtual resistance, which play a pivotal role in stabilizing the system. Furthermore, this work theoretically investigates how the virtual resistance and current loop’s proportional-integral (PI) parameters jointly influence transient stability, demonstrating that increasing the virtual resistance while reducing the integral gain of the current loop significantly enhances synchronization stability. Simulation results validate the accuracy of the model and the effectiveness of the proposed analysis. The findings provide a theoretical foundation for optimizing control parameters and improving the stability of DFIG-based wind turbines during grid faults.
With the increase in wind power penetration, the stable operation of wind turbines under the new power system is facing severe challenges. The grid-forming wind power technology operates in a self-synchronous mode, which can provide voltage and frequency support for the system without being affected by the phase-locked loop, and is also suitable for operation under weak power grids. However, the current research for the grid-forming (GFM) permanent magnet synchronous generator (PMSG) ignores the DC-link dynamics generated by the wind turbine, which makes the sub-synchronous oscillation (SSO) phenomenon under different grid conditions and lacks a physical explanation. In this paper, the SSO problem in the grid-forming PMSG is studied, and the study reveals that the reduction in the DC-link voltage control bandwidth of the machine-side converter (MSC) is the main cause. To this end, an improved damping method is proposed, which introduces a low-pass filter branch in the reactive power control loop and takes the DC-link voltage tracking error as a compensation term. The small-signal analysis and simulation results show that the proposed method has significant effectiveness.