Xiaoxiao Jin

Dr. Xiaoxiao Jin


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2018 in Mathematics and Mechanics of Solids
Verified
Journal Article
Closed access
XJXiaoxiao Jin
Xiaoxiao Jin
A transversely isotropic half space with surface effects subjected to axisymmetric loadings is investigated in terms of the Lekhnitskii formulism. Surface effects including residual surface stress and surface elasticity are introduced by using the Gurtin–Murdoch continuum model. With the aid of the Hankel transforms, solutions corresponding to several different axisymmetic loadings are derived and used to determine the influence of surface effects on contact stiffness in nanoindentations. Numerical results are provided to show the influence of surface effects and material anisotropy on the material behaviours. Meanwhile, the obtained analytical Green’s functions for two special cases can be used as building blocks for further mixed boundary value problems.

1 March 2019 in Journal of the Franklin Institute
Verified
Journal Article
Closed access
JLJinxing Lin
Jinxing Lin
Xudong ZhaoXudong Zhao
Xudong Zhao
MXMin Xiao
Min Xiao
XJXiaoxiao Jin
Xiaoxiao Jin

11 April 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CLChenggang Li
Chenggang Li
DYDengdeng Yan
Dengdeng Yan
XJXiaoxiao Jin
Xiaoxiao Jin
Because of the finite development of tactile feedback in surgical catheter of minimally invasive surgery (MIS), a convex tactile sensor composed of a force sensor, an indenter and some sensitive elements is proposed. To measure the relative hardness and elastic modulus of isotropic tissue contacted with the indenter, the contact model is derived based on the Eshelby-Stroh formula, and is solved based on the boundary conditions of indenter and tissue. The global displacement constraint method, local stress inversion constraint method, and multiple linear superposition are used to overcome the problems of abrupt changes of contact stress at the junctions and non-zero contact stress distributions in non-contact areas. The proposed method has the potential of higher calculation accuracy than Meijers’ solution when the termination condition is specified to be smaller. With known width and depth of indentation, it is easy for this sensor to determine the elastic modulus directly according to the measured load compared with the state-of-the-art tactile sensors. Two indenters are processed, and three kinds of silica gel with different elastic moduli are tested. The feasibility and effectiveness of the tactile sensors are verified by comparing the test results with the results of silica gel in the previous study.

1 August 2016 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
XJXiaoxiao Jin
Xiaoxiao Jin
FXFeng Yu Xu
Feng Yu Xu
WYWen An Yang
Wen An Yang

1 November 2018 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
FWFang Fang Wang
Fang Fang Wang
XJXiaoxiao Jin
Xiaoxiao Jin
YWYa Yong Wu
Ya Yong Wu

9 October 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZXZhi Hao Xu
Zhi Hao Xu
XJXiaoxiao Jin
Xiaoxiao Jin
FWFang Fang Wang
Fang Fang Wang
Jiang ZhaoJiang Zhao
Jiang Zhao
RXRong Qing Xu
Rong Qing Xu
Flexible capacitive proximity/tactile dual-mode sensor arrays are emerging as a transformative technology for next-generation intelligent systems, including human-computer interaction, virtual reality, and intelligent robotics. These applications demand sensors with high sensitivity, spatial consistency, and cost-effective manufacturability. In this study, we present a novel flexible capacitive dual-mode sensor array based on a diamond-shaped electrode structure, designed to enhance key sensor performance metrics, including sensitivity, spatial consistency, and integration. The sensor array features interleaved and complementary upper and bottom electrodes, fabricated using a simple and scalable screen-printing technique. This unique electrode configuration optimizes the fringing capacitance effects, significantly enhancing sensitivity in proximity mode while ensuring high spatial consistency due to the uniform distribution of the electric field. Experimental results demonstrate that the proposed sensor array achieves a remarkable relative capacitance change of up to 78.14%, enabling robust object detection within a 10 cm range in proximity mode and precise measurement of applied pressure in tactile mode. The sensor array exhibits a rapid response and recovery time of 90 ms. Its performance was further validated through practical applications, including finger position tracking and measurements under various bending configurations. The results confirmed the sensor array has high stability, sensitivity, and spatial resolution, even under mechanical deformation. This implies its adaptability to curved surfaces and dynamic environments.