Gulfem Ergun

Prof. Dr. Gulfem Ergun


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2005 in Dental Materials Journal
Verified
Journal Article
Closed access
PDF file
GEGulfem Ergun
Gulfem Ergun
LMLâmia Mutlu-Sagesen
Lâmia Mutlu-Sagesen
YÖYalçin Özkan
Yalçin Özkan
EDErol Demirel
Erol Demirel
Discoloration of provisional restorations can be an esthetic problem, especially when the treatment plan requires long-term provisionalization. In this study, therefore, we examined the effects of staining solution on the color stability of these provisional crown and bridge restoration materials: Structur, Temdent, and Tab 2000. Treatment solutions were namely carrot juice, tea, cola, light cola, and distilled water. Thirty samples were prepared for each type of provisional material, such that a total of 90 samples were prepared. The color value of each sample was measured with a colorimeter at baseline and after one day, one week, two weeks, and four weeks of immersion in various treatment solutions. Results were determined using the CIELAB system. Color change data were calculated and subjected to two-way analysis of variance. To examine significant interactions, one-way ANOVA and Tukey's multiple comparisons test were performed to identify differences between the solutions (p < or = 0.05). After four weeks of treatment, color difference values were found to range from 0.20 to 3.99 deltaE* units. The highest color difference values were obtained in carrot juice, cola, and tea with Structur samples after four weeks, where these values were categorized as "noticeable" and "unacceptable" color change values. Based on the results of this study, we do not recommend amine-containing Structur to be used as a provisional crown and bridge restorative material for treatments of a longer duration.

1 July 2007 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
GEGulfem Ergun
Gulfem Ergun
INIsil Cekic Nagas
Isil Cekic Nagas
Objectives: The aim of this study was to compare the color stability of three acrylic based hard liners (Ufi gel hard, Dura-Liner II, Tokuso Rebase) and two silicone based soft liners (Ufi gel permanent, Molloplast B) by using the colorimeter.Methods: Sixty disc-shaped samples, with uniform size of 10 mm diameter and 2 mm in thickness were fabricated for each material. Thirty samples were made as control group in distilled water and the remaining thirty samples were weathered in accelerated aging chamber. Color measurements were made before and after distilled water and aging. Data were statistically analyzed using nonparametric Kruskal-Wallis and Mann-Whitney U tests.Results: Data showed that there are significant differences among materials in both after distilled water and aging treatments (P>.001). These results indicated that the most discolored liner material was Dura Liner II after aging (ΔE*=16.30) and the least discolored material was Ufi gel permanent after distilled water (ΔE*=0.41).Conclusions: Based on the results of this study, silicone based liner materials are considered to be more color stable than acrylic based liner materials. (Eur J Dent 2007;1:144-151)

1 February 2007 in International Endodontic Journal
Verified
Journal Article
Closed access
PDF file
GEGulfem Ergun
Gulfem Ergun
FEF. Eğilmez
F. Eğilmez
MÜM B Üçtaşli
M B Üçtaşli
MBM. B.
M. B.
ŞYŞ. Yilmaz
Ş. Yilmaz

1 June 2011 in Journal of Applied Oral Science
Verified
Journal Article
Open access
PDF file
GEGulfem Ergun
Gulfem Ergun
FEFerhan Egilmez
Ferhan Egilmez
SYSukran Yilmaz
Sukran Yilmaz
Applications of resin luting agents and high-power light-emitting diodes (LED) light-curing units (LCUs) have increased considerably over the last few years. However, it is not clear whether the effect of reduced exposure time on cytotoxicity of such products have adequate biocompatibility to meet clinical success. This study aimed at assessing the effect of reduced curing time of five resin luting cements (RLCs) polymerized by high-power LED curing unit on the viability of a cell of L-929 fibroblast cells. Disc-shaped samples were prepared in polytetrafluoroethylene moulds with cylindrical cavities. The samples were irradiated from the top through the ceramic discs and acetate strips using LED LCU for 20 s (50% of the manufacturer's recommended exposure time) and 40 s (100% exposure time). After curing, the samples were transferred into a culture medium for 24 h. The eluates were obtained and pipetted onto L-929 fibroblast cultures (3x104 per well) and incubated for evaluating after 24 h. Measurements were performed by dimethylthiazol diphenyltetrazolium assay. Statistical significance was determined by two-way ANOVA and two independent samples were compared by t-test. Results showed that eluates of most of the materials polymerized for 20 s (except Rely X Unicem and Illusion) reduced to a higher extent cell viability compared to samples of the same materials polymerized for 40 s. Illusion exhibited the least cytotoxicity for 20 s exposure time compared to the control (culture without samples) followed by Rely X Unicem and Rely X ARC (90.81%, 88.90%, and 83.11%, respectively). For Rely X ARC, Duolink and Lute-It 40 s exposure time was better (t=-1.262 p=0,276; t=-9.399 p=0.001; and t=-20.418 p<0.001, respectively). The results of this study suggest that reduction of curing time significantly enhances the cytotoxicity of the studied resin cement materials, therefore compromising their clinical performance.

1 May 2013 in Journal of Oral Implantology
Verified
Journal Article
Closed access
GEGulfem Ergun
Gulfem Ergun
FEFerhan Egilmez
Ferhan Egilmez
ICIsil Cekic-Nagas
Isil Cekic-Nagas
IKİnCi Rana Karaca
İnCi Rana Karaca
SBSuleyman Bozkaya
Suleyman Bozkaya
This study evaluated the effect of local application of platelet-rich plasma (PRP) on the outcome of early loaded implants. Two implants were placed in the posterior region or bilaterally symmetric to the median line of the maxilla. Then, PRP was either applied or not applied to the implant sockets. Outcome measures were prosthesis and implant success as well as biological and prosthetic complications. Stability of individual implants was assessed manually and with a resonance frequency analysis device. The implant stability quotient (ISQ) was recorded on the operation day, on postoperative day 4, and at postoperative week 1. At the end of the first postoperative week, implants with ISQ values >60 were early loaded on day 7 with metal-ceramic crowns. Measurements were repeated at postoperative weeks 2, 3, and 4 and at postoperative months 6, 12, 24, and 36. One of the 64 implants was dropped out after 3 months of loading. No prosthesis failed. There were no prosthetic complications. Statistical analysis revealed significant differences between ISQ values of PRP and non-PRP implants on the operation day. Moreover, no statistically significant differences were found between ISQ values of PRP and non-PRP implants in the follow-up periods ( P > .05). No appreciable clinical effect was observed when using PRP in the maxilla.

1 October 2012 in Journal of Oral Implantology
Verified
Journal Article
Closed access
GEGulfem Ergun
Gulfem Ergun
ICIsil Cekic-Nagas
Isil Cekic-Nagas
Oligodontia is defined as the absence of 6 or more permanent teeth due to the hypodevelopment of tooth germs. This familial abnormality is attributable to various mutations or polymorphisms of genes and associated with malformative syndromes. This clinical report presents the multidisciplinary dental treatment planning for a 27-year-old woman who exhibited oligodontia. After radiographic and clinical evaluations, 7 retained primary teeth and 2 mandibular third molars were extracted. Three dental implants were placed into the maxillary alveolar process. After the osseointegration period, complete-arch fixed prostheses in both maxilla and mandible, supported by a combination of implants and teeth, were fabricated. Osseointegration of the implants, peri-implant mucosa health, and prosthesis function were assessed every 6 months. At the end of the 3-year clinical follow-up, the patient was satisfied with the esthetics, function, and phonation of her prosthesis. To attain the best esthetic and biological results, an interdisciplinary approach could be used to synergistically combine surgery and restorative dentistry for the restoration of maximal esthetics and function.