Objective of the study is to evaluate volumetric and dosimetric alterations taking place during radiotherapy for locally advanced head and neck cancer (LAHNC) and to assess benefit of replanning in them. Thirty patients with LAHNC fulfilling the inclusion and exclusion criteria were enrolled in a prospective study. Planning scans were acquired both pre-treatment and after 20 fractions (mid-course) of radiotherapy. Single plan (OPLAN) based on initial CT scan was generated and executed for entire treatment course. Beam configuration of OPLAN was applied to anatomy of interim scan and a hybrid plan (HPLAN30) was generated. Adaptive replanning (RPLAN30) for remaining fractions was done and dose distribution with and without replanning compared for remaining fractions. Substantial shrinkage of target volume (TV) and parotids after 4 weeks of radiotherapy was reported (p<0.05). No significant difference between planned and delivered doses was seen for remaining fractions. Hybrid plans showed increase in delivered dose to spinal cord and parotids for remaining fractions. Interim replanning improved homogeneity of treatment plan and significantly reduced doses to cord (Dmax, D2% and D1%) and ipsilateral parotid (D33%, D50% and D66%) (p<0.05). Use of one or two mid-treatment CT scans and replanning provides greater normal tissue sparing alongwith improved TV coverage.
1 April 2019 in Asian Pacific Journal of Cancer Prevention
Background: Early diagnosis of ovarian cancer is essential for long term disease control and mortality reduction.This has been achieved using tumor markers like cancer antigen 125 (CA-125) which is elevated in malignant as wellas non-malignant conditions. This dilemma led to efforts towards development of newer markers like serum humanepididymis secretory protein E4 (HE4). Present study aimed to evaluate role of HE4 in diagnosing ovarian cancersand comparing it with CA-125. Methods: Serum samples from 67 patients with ovarian cancer, 42 with benignovarian masses and 26 healthy controls were collected preoperatively and tested for serum HE4 levels and CA-125levels. Diagnostic performance of both tumor markers (HE4/CA-125) to diagnose malignancy in ovarian masses wascalculated and compared to each other. Results: Mean CA-125 and HE4 levels were significantly higher in patientswith ovarian cancer than in those with benign disease (p<0.001) or healthy controls (p< 0.001). Serum HE4 levelssignificantly increased in epithelial ovarian cancers when compared to non-epithelial ovarian cancers (p<0.01). Usingbenign control as comparison, receiver operating characteristic curve (ROC) was generated to predict a cut-off valuefor diagnosing malignancy for serum HE4 and CA-125. Compared to CA-125, HE4 had a similar sensitivity (83.6%vs. 85.10%) and higher specificity (100% vs. 90.48%); combination of serum HE4 and CA-125 improved the sensitivityto detect ovarian cancer to 92.54%. Sensitivity of HE4 to detect early stage ovarian cancer was superior to CA-125(92.61% vs. 63.41%). Conclusion: Serum HE4, a novel tumor marker, discriminated epithelial ovarian cancer frombenign ovarian masses. HE4 levels were related to the stage and histological types with the lowest levels in mucinousepithelial ovarian cancer and non-epithelial malignancy. Measuring serum HE4 levels alongwith CA-125 may providehigher accuracy for detecting epithelial ovarian cancer particularly in the early stages.
8 September 2016 in Journal of Gastrointestinal Cancer
Background: To evaluate the dosimetric impact of variable bladder filling on target and organ at risk (OARs) in cervical cancer patients undergoing chemoradiation. Forty consecutive patients with cervical cancer underwent radiotherapy planning as per the departmental protocol. All patients were asked to empty their bowel and bladder before simulation and catheterization was done. Normal saline was instilled into the bladder through Foleys till the patient had a maximal urge to urinate. Pelvic cast fabrication and CT simulation was done. Then, 30%, 50%, and 100% of the instilled saline was removed and rescans taken. Planning was done on full bladder (X) and the same plan applied to the contours with bladder volumes 0.7X (PLAN70), 0.5X (PLAN50), and empty (PLAN0). A dose of 50 Gy/25# was prescribed to the PTV and plans evaluated. Intensity-modulated radiotherapy plans with full bladder were implemented for each patient. Shifts in the center of mass (COM) of the cervix/uterus with variable bladder filling identified were noted. Statistical analysis was performed using SPSS software. A p value < 0.05 was considered significant. Results: Bladder volume in 70%, 50%, and empty bladder planning was 78.34% (388.35 + 117.44 ml), 64.44% (320.60 + 106.20 ml), and 13.63% (62.60 + 23.12 ml), respectively. The mean dose received by 95% PTV was 49.76 Gy + 1.30 Gy. Though the difference in target coverage was significant between PLAN100 and other plans, the mean difference was minimal. A decrease in bladder filling resulted in an increase in OAR dose. Variation in the increase in dose to OARs was not significant if bladder filling was > 78.34% and > 64.44% of a full bladder with respect to the bowel and rectal/bladder doses, respectively. Inconsistent bladder filling led to a maximal shift in COM (uterus/cervix) in the Y- and Z-axis. Conclusion: Bladder filling variations have an impact on cervico-uterine motion/shape, thereby impacting the dose to the target and OARs. It is recommended to have a threshold bladder volume of at least 70–75% of optimally filled bladder during daily treatment. Trial registration: Institutional review board (IRB) registered by Drug Controller General (India) with registration number ECR/10/Ins/DC/2013. Trial Registration number - RGCIRC/IRB/44/2016, registered and approved on the 14th of May 2016.
17 December 2014 in International Journal of Clinical Oncology
To study feasibility of simultaneous integrated boost by intensity modulated radiotherapy (SIB-IMRT) in patients undergoing breast conserving surgery and its impact on cosmesis and dosimetry. Between January 2014 and June 2017, all breast cancer patients fulfilling inclusion and exclusion criteria were enrolled in a prospective study conducted at a tertiary cancer centre in North India. All patients received adjuvant radiotherapy by simultaneous integrated boost technique following breast conserving surgery. Clinical information including patient and pathological characteristics, observed acute and chronic toxicities along with cosmesis using Harvard score were recorded and analysed. Univariate analysis and multivariate logistic regression analysis were performed for those variables which were found to be significant (p < 0.050) to study the influence of clinicopathological and dosimetric factors on toxicity and cosmetic outcome. Maximum acute skin toxicity during treatment was Grade 0-1 in 68.2% and Grade 2-3 in 31.8% of cases, respectively. Fibrosis was the commonest late toxicity with ≥Grade II fibrosis being noted in 16.3% of cases. Assessment of global cosmesis at 12 months follow-up showed good/excellent cosmesis in 88.4% of cases. Mean age, tumor size and homogeneity index (HI) were the significant factors associated with fair or poor cosmetic outcome and ≥Grade 2 fibrosis on multivariate analysis. Telengectasia and breast edema were more frequent in patients with larger tumor size/GTV volume. There were 5 recurrences including 1 ipsilateral local breast tumor recurrence. SIB-IMRT is a dosimetrically feasible option in patients undergoing breast conserving surgery and provides good/excellent cosmetic outcome.