Utku Demirtas

Dr. Utku Demirtas

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2026 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
MEMurat Erem
Murat Erem
UDUtku Demirtas
Utku Demirtas
SYSavaş Yıldırım
Savaş Yıldırım
ESEşref Selçuk
Eşref Selçuk
CÇCem Çopuroğlu
Cem Çopuroğlu
Introduction: Surgical stabilization of Pauwels Type III femoral neck fractures remains a significant challenge due to high vertical shear forces. While the medial buttress plate is a recognized solution, it requires extensive deep dissection. This study aims to compare the biomechanical performance of various screw configurations combined with either a medial buttress or anteromedial support plate. Materials and methods: Twenty-five third-generation synthetic femurs were used to create a standardized 70-degree (Pauwels III) fracture model. Specimens were divided into five groups ( n = 5): (A) Inverted triangle (IT) screws with a Pauwels screw, (B) Inverted triangle (IT) with medial buttress plate (MBP), (C) Inverted triangle with anteromedial support plate (ASP), (D) L-configuration with medial buttress plate (MBP), and (E) L-configuration with anteromedial support plate (ASP). Axial loading was applied at 2 mm/min until construct failure, defined objectively by the real-time force-distance curve. Results: Although no statistically significant difference was found between groups ( p = 0.102), a large effect size was observed (η² = 0.309). Group C (IT + ASP) demonstrated the highest mean failure load (1695 ± 494.6 N). Conversely, Group E (L-configuration + ASP) exhibited the lowest stability (977.2 ± 195.4 N) with a remarkably narrow standard deviation. The majority of failures occurred as transverse subtrochanteric fractures distal to the implants. Conclusion: The combination of an inverted triangle screw arrangement with an anteromedial support plate demonstrated comparable biomechanical stability to the medial buttress plate, while offering a potentially safer surgical corridor. Conversely, pairing L-shaped screw configurations with anteromedial support plates resulted in the lowest mean ultimate load-to-failure among the tested constructs, likely due to potential stress riser effects.

28 March 2026 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
UDUtku Demirtas
Utku Demirtas
OIOsman Iyibilgin
Osman Iyibilgin
LBlevent bayam
levent bayam
EGErdinç Genç
Erdinç Genç
Introduction: The purpose of this study was to perform biomechanical pull-out comparisons between composite bone blocks and additively manufactured bone models using locked plate and screw systems. The hypothesis posited that the mean pull-out force of the 3D-printed models would demonstrate non-inferior pull-out strength compared to standard composite bones within a clinically acceptable 15% margin. A standardized pull-out mechanism was developed to evaluate its biomechanical reliability and its potential as a customizable alternative. Materials and methods: The study compared three groups: standard composite (Sawbones) blocks and two types of additively manufactured polylactic acid (PLA) blocks (grid and gyroid infill pattern), each measuring the same dimensions with 30% infill and mimicking a Sawbones block with 2 mm cortical thickness. A 6-hole LC-DCP titanium plate was fixed onto bone block models with dimensions of 29 × 170 × 42 mm using four screws, each measuring 36 mm in length, which were inserted perpendicularly and tightened to the same torque levels. Steel cables placed under the plate were connected to a mechanical testing setup, and pull-out tests were conducted to evaluate fixation strength. Seven replicate specimens were fabricated to ensure repeatability and reliability of the results. Results: Mean pull-out forces were 1784.4 ± 79.9 N for Sawbones, 1698.5 ± 134.3 N for Grid PLA ( n = 7), and 1908.7 ± 335.2 N for Gyroid PLA ( n = 7). Statistical analysis using a one-sample t-test showed that both 3D-printed models were non-inferior to the standard Sawbones model within a clinical acceptance margin of 15% ( p < 0.05). Conclusions: Additively manufactured models exhibit mechanical pull-out performance that is statistically non-inferior to traditional composite bone block models. These findings confirm that 3D-printed PLA-based grid and gyroid structures serve as reliable, cost-effective alternatives for orthopaedic mechanical research without compromising mechanical integrity.