Deepu George

Deepu George

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2012 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
RAR. Valdés Aguilar
R. Valdés Aguilar
ASA. V. Stier
A. V. Stier
WLW. Liu
W. Liu
LBL. S. Bilbro
L. S. Bilbro
DGDeepu George
Deepu George
NAN. P. Armitage
N. P. Armitage
We report the THz response of thin films of the topological insulator Bi2Se3. At low frequencies, transport is essentially thickness independent showing the dominant contribution of the surface electrons. Despite their extended exposure to ambient conditions, these surfaces exhibit robust properties including narrow, almost thickness-independent Drude peaks, and an unprecedentedly large polarization rotation of linearly polarized light reflected in an applied magnetic field. This Kerr rotation can be as large as 65° and can be explained by a cyclotron resonance effect of the surface states.

22 April 2015 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
PDF file
NVN. Q. Vinh
N. Q. Vinh
MSMark S. Sherwin
Mark S. Sherwin
SAS. James Allen
S. James Allen
DGDeepu George
Deepu George
ARA. J. Rahmani
A. J. Rahmani
KPKevin W. Plaxco
Kevin W. Plaxco
Because it is sensitive to fluctuations occurring over femtoseconds to picoseconds, gigahertz-to-terahertz dielectric relaxation spectroscopy can provide a valuable window into water’s most rapid intermolecular motions. In response, we have built a vector network analyzer dielectric spectrometer capable of measuring absorbance and index of refraction in this frequency regime with unprecedented precision. Using this to determine the complex dielectric response of water and aqueous salt solutions from 5.9 GHz to 1.12 THz (which we provide in the supplementary material), we have obtained strong new constraints on theories of water’s collective dynamics. For example, while the salt-dependencies we observe for water’s two slower relaxations (8 and 1 ps) are easily reconciled with suggestions that they arise due to rotations of fully and partially hydrogen bonded molecules, respectively, the salt-dependence of the fastest relaxation (180 fs) appears difficult to reconcile with its prior assignment to liberations of single hydrogen bonds.

4 March 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
KNKatherine A. Niessen
Katherine A. Niessen
MXMengyang Xu
Mengyang Xu
DGDeepu George
Deepu George
MCMichael C. Chen
Michael C. Chen
AFAdrian R. Ferré-D’aMaré
Adrian R. Ferré-D’aMaré
AMAndrea G. Markelz
Andrea G. Markelz
Protein structural vibrations impact biology by steering the structure to functional intermediate states; enhancing tunneling events; and optimizing energy transfer. Strong water absorption and a broad continuous vibrational density of states have prevented optical identification of these vibrations. Recently spectroscopic signatures that change with functional state were measured using anisotropic terahertz microscopy. The technique however has complex sample positioning requirements and long measurement times, limiting access for the biomolecular community. Here we demonstrate that a simplified system increases spectroscopic structure to dynamically fingerprint biomacromolecules with a factor of 6 reduction in data acquisition time. Using this technique, polarization varying anisotropy terahertz microscopy, we show sensitivity to inhibitor binding and unique vibrational spectra for several proteins and an RNA G-quadruplex. The technique’s sensitivity to anisotropic absorbance and birefringence provides rapid assessment of macromolecular dynamics that impact biology.

1 December 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DGDeepu George
Deepu George
ACAli Charkhesht
Ali Charkhesht
NVN. Q. Vinh
N. Q. Vinh
We present the development of a high precision, tunable far-infrared (terahertz) frequency-domain dielectric spectrometer for studying the dynamics of biomolecules in aqueous solutions in the gigahertz-to-terahertz frequency. As an important benchmark system, we report on the measurements of the absorption and refractive index for liquid water in the frequency range from 5 GHz to 1.12 THz (0.17–37.36 cm−1 or 0.268–60 mm). The system provides a coherent radiation source with power up to 20 mW in the gigahertz-to-terahertz region. The dynamic range of our instrument reaches 1012 and the system achieves a spectral resolution of less than 100 Hz. The temperature of samples can be controlled precisely with error bars of ±0.02 °C from 0 °C to 90 °C. Given these attributes, our spectrometer provides unique capabilities for the accurate measurement of even very strongly absorbing materials such as aqueous solutions.

7 October 2016 in The Journal of Physical Chemistry B
Verified
Journal Article
Closed access
DGDeepu George
Deepu George
ACAli Charkhesht
Ali Charkhesht
OHOlivia A. Hull
Olivia A. Hull
AMArchana Mishra
Archana Mishra
DCDaniel G. S. Capelluto
Daniel G. S. Capelluto
NVNguyen Q. Vinh
Nguyen Q. Vinh

25 May 2012 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
PDF file
DGDeepu George
Deepu George
ASAndreas V. Stier
Andreas V. Stier
CEChase T. Ellis
Chase T. Ellis
BMBruce D. McCombe
Bruce D. McCombe
JČJohn Černe
John Černe
AMAndrea G. Markelz
Andrea G. Markelz
We report the development of new terahertz (THz) techniques for rapidly measuring the complex Faraday angle in systems with broken time-reversal symmetry. Using the cyclotron resonance of a GaAs two-dimensional electron gas in a magnetic field, we have tested the performance of the techniques. We have made polarization modulation, high sensitivity (<1  mrad) narrowband rotation measurements with a cw optically pumped molecular gas laser, and, by combining the distinct advantages of THz time domain spectroscopy and polarization modulation techniques, we have demonstrated rapid broadband rotation measurements to <5  mrad precision.