Acute myocardial infarction (AMI) and other forms of myocardial acute oxidative stress are associated with variable "shedding" of the endothelial glycocalyx (GCS) which can be quantitated ex vivo by release into plasma of glycocalyx components such as Syndecan-1 (SD-1). Previous studies have implicated release of both catecholamines and BNP as potential accentuating factors in GCS: since these are prominent aspects of the pathogenesis of Takotsubo cardiomyopathy (TTC), we hypothesised that TTC is associated with increased GCS and the extent of GCS is predictable on the basis of NT-proBNP and catecholamine releases. SD-1 concentrations were measured in 48 TTC patients acutely and after 3months, and compared with those in 12 healthy controls, and 17 patients with AMI. Correlations were sought between SD-1 levels markers of severity of TTC episodes in individual patients. Acute SD-1 concentrations in TTC patients were elevated significantly (p<0.0001, 1-way ANOVA) compared to control values. There were no significant correlations between SD-1 concentrations and any markers of severity of acute TTC episodes, such as NT-proBNP or catecholamine release. Over 3months, SD-1 concentrations fell significantly (p=0.0002) to approximately the same values as in control subjects. TTC is associated acutely with a marked increase in GCS. Potentially, GCS might contribute to increased coronary vascular permeability in TTC, thus dissociating development of myocardial oedema from severity of associated inflammation. Prevention of GCS represents a potential therapeutic option in TTC.
15 September 2011 in The Journal of ExtraCorporeal Technology
The delivery of gaseous microemboli (GME) by the cardiopulmonary bypass circuit should be minimized whenever possible. Innovations in components, such as the integration of arterial line filter (ALF) and ALFs with reduced priming volumes, have provided clinicians with circuit design options. However, before adopting these components clinically, their GME handling ability should be assessed. This study aims to compare the GME handling ability of different oxygenator/ALF combinations with our currently utilized combination. Five commercially available oxygenator/ALF combinations were evaluated in vitro: Terumo Capiox SX25RX and Dideco D734 (SX/ D734),Terumo Capiox RX25R and AF125 (RX/AF125),Terumo FX25R (FX), Sorin Synthesis with 102 μm reservoir filter (SYN102), and Sorin Synthesis with 40 μm reservoir filter (SYN40). GME handling was studied by introducing air into the venous return at 100 mL/min for 60 seconds under two flow/ pressure combinations : 3.5 L/min, 150 mmHg and 5 L/min, 200 mmHg. Emboli were measured at three positions in the circuit using the Emboli Detection and Classification (EDAC®) Quantifier and analyzed with the General Linear Model. All circuits significantly reduced GME. The SX/D734 and SYN40 circuits were most efficient in GME removal whilst the SYN102 handled embolic load (count and volume) least efficiently (p < .001). A greater number of emboli <70 μm were observed for the SYN102, FX and RX/AF125 circuits (p < .001). An increase in embolic load occurred with higher flow/pressure in all circuits (p < .001). The venous reservoir significantly influences embolic load delivered to the oxygenator (p < .001). The majority of introduced venous air was removed; however, significant variation existed in the ability of the different circuits to handle GME. Venous reservoir design influenced the overall GME handling ability. GME removal was less efficient at higher flow and pressure, and for smaller sized emboli. The clinical significance of reducing GME requires further investigation.