Shinya Komori

Dr. Shinya Komori

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2023 in Physica Medica
Verified
Journal Article
Closed access
SKShinya Komori
Shinya Komori
KHKatsumi Hirose
Katsumi Hirose
ATAkihiko Takeuchi
Akihiko Takeuchi
RKRyohei Kato
Ryohei Kato
TMTomoaki Motoyanagi
Tomoaki Motoyanagi
YTYoshihiro Takai
Yoshihiro Takai

2 October 2024 in Physica Medica
Verified
Journal Article
Closed access
SKShinya Komori
Shinya Komori
KHKatsumi Hirose
Katsumi Hirose
MSMariko Sato
Mariko Sato
YYYuhei Yamazaki
Yuhei Yamazaki
ATAkihiko Takeuchi
Akihiko Takeuchi
YTYoshihiro Takai
Yoshihiro Takai

27 April 2022 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
SKShinya Komori
Shinya Komori
KHKatsumi Hirose
Katsumi Hirose
MSMariko Sato
Mariko Sato
ATAkihiko Takeuchi
Akihiko Takeuchi
RKRyohei Kato
Ryohei Kato
YTYoshihiro Takai
Yoshihiro Takai
The dosimetric effect of set-up error in boron neutron capture therapy (BNCT) for head and neck cancer remains unclear. In this study, we analyzed the tendency of dose error by treatment location when simulating the set-up error of patients. We also determined the tolerance level of the set-up error in BNCT for head and neck cancer. As a method, the distal direction was shifted with an interval of 2.5 mm, from 0.0 mm to +20.0 mm and compared with the dose at the reference position. Similarly, the horizontal direction and vertical direction were shifted, with an interval of 5.0 mm, from −20.0 mm to +20.0 mm. In addition, cases with 3.0 mm and 5.0 mm simultaneous shifts in all directions were analyzed as the worst-case scenario. The dose metrics of the minimum dose of the tumor and the maximum dose of the mucosa were evaluated. From unidirectional set-up error analysis, in most cases, the set-up errors with dose errors within ±5% were Δdistal < +2.5 mm, Δhorizontal < ±5.0 mm and Δvertical < ±5.0 mm. In the simulation of 3.0 mm shifts in all directions, the errors in the minimum tumor dose and maximum mucosal dose were −3.6% ±1.4% (range, −5.4% to −0.6%) and 2% ±1.4% (range, 0.4% to 4.5%), respectively. From these results, if the set-up error was within ±3.0 mm in each direction, the dose errors of the tumor and mucosa could be suppressed within approximately ±5%, which is suggested as a tolerance level.

25 March 2022 in Medical Dosimetry
Verified
Journal Article
Closed access
TKTakahiro Kato
Takahiro Kato
TOTakashi Ono
Takashi Ono
YNYuki Narita
Yuki Narita
SKShinya Komori
Shinya Komori
MMMasao Murakami
Masao Murakami

18 September 2024 in Medical Physics
Verified
Journal Article
Closed access
SKShinya Komori
Shinya Komori
ATAkihiko Takeuchi
Akihiko Takeuchi
RKRyohei Kato
Ryohei Kato
YYYuhei Yamazaki
Yuhei Yamazaki
TMTomoaki Motoyanagi
Tomoaki Motoyanagi
YTYoshihiro Takai
Yoshihiro Takai

7 September 2025 in Brachytherapy
Verified
Journal Article
Closed access
SKShinya Komori
Shinya Komori
YTYoshiaki Takagawa
Yoshiaki Takagawa
HSHiroki Sato
Hiroki Sato
MMMasanori Machida
Masanori Machida
MKMasato Kato
Masato Kato
TKTakahiro Kato
Takahiro Kato