A novel scheme for fast detection of islanding events in a microgrid is proposed in this paper. The scheme consists of a passive islanding detection process using an adaptive ensemble classifier and measurements of three-phase voltage at the distributed generation (DG) terminals. Initial features inputs to the classifier are obtained using the phase-space method. They are then used to train an ensemble classifier which comprises a set of randomized neural networks called extreme learning machine (ELM). The optimal parameter settings for each ELM are identified through evolutionary computation. An adaptive decision mechanism is designed to progressively adjust the decision time of the events classification, where its decision speed can be significantly improved over existing methods. Extensive tests are conducted on a radial distribution system with two identical DG units and the IEEE 33-bus with four DG units, considering various scenarios of islanding and non-islanding conditions, as well as the different types of DG. The simulation results show that the proposed scheme can make accurate decisions at appropriately earlier times, which achieves a good balance between efficiency and accuracy in detecting the islanding events.
1 November 2015 in IET Generation, Transmission & Distribution
This study presents a novel islanding detection and optimal load shedding scheme for radial distribution systems integrated with dispersed generation (DG). A simple and effective passive islanding detection method is developed based on the phase‐space technique and using a probabilistic neural network‐based classifier. After the system detects unintentional islanding state, it utilises an optimal load shedding scheme to prevent system collapse due to load‐generation mismatch and voltage instability encountered in the islanded part of the system. The optimal load shedding scheme is developed based on the backtracking search algorithm. Extensive tests conducted with the DigSilent Power Factory ® software and MATLAB ® software on the IEEE 33‐bus system with four DG units considering several scenarios of islanding condition were utilised to evaluate the effectiveness of the proposed islanding detection method and the optimal load shedding scheme. The results showed that the proposed method can effectively detect the islanding events and stabilise the islanded part of the system with minimum load curtailment.
This paper aimed at comparing the performance of bidirectional converter designs for renewable source power generation such as wind. The bidirectional converter is supposed to allow a bidirectional power flow between power line and a battery system. In order to determine the most applicable bidirectional converter circuit which meets a set of requirements, four types of designs which were based on previous work of others were simulated with PSCAD software. The ability of each design to maintain a set voltage at the power line and also the direction of current flows at the battery as well as at the output of the converter are investigated.
13 July 2023 in Arabian Journal for Science and Engineering
This paper presents the performance evaluation of a double chamber microbial fuel cell (MFC) to obtain the maximum amount of power production. Previous works have shown that the performance of a double chamber MFC varies depending on the design of the MFC and the type of waste water. Therefore, various MFC tests were conducted to obtain the maximum amount of power production by varying the distance of electrodes and thickness of the electrode. The types of water were also varied (i.e., fertilizer water, lake water, and soil water) to highlight the effect of the expected different amount of microbes. The experimental results demonstrated that the thicker anode (0.6 cm) and the shorter distances between electrodes (15 cm) showed higher amount of power production in all the three types of waste water. Furthermore, the fertilizer water generated a higher amount of power compared to the soil and lake water.