Rooftop and building-integrated distributed photovoltaic (PV) systems are emerging as key technologies for smart building applications. This paper presents the design methodology, mathematical analysis, simulation study, and experimental validation of a digital twin approach for fault diagnosis. We develop a digital twin that estimates the measurable characteristic outputs of a PV energy conversion unit (PVECU) in real time. The PVECU constitutes a PV source and a source-level power converter. The fault diagnosis is performed by generating and evaluating an error residual vector, which is the difference between the estimated and measured outputs. A PV panel-level power converter prototype is built to demonstrate how the sensing, processing, and actuation capabilities of the converter can enable effective fault diagnosis in real time. The experimental results show detection and identification of ten different faults in the PVECU. The time to fault detection (FD) in the power converter and the electrical sensors is less than 290 μs and the identification time is less than 4 ms. The time to FD and identification in the PV panel are less than 80 ms and 1.2 s, respectively. The proposed approach demonstrates higher fault sensitivity than that of existing approaches. It can diagnose a 20% drift in the electrical sensor gains and a 20% shading of a solar cell in the PV panel.

23 December 2010 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YTYen Kheng Tan
Yen Kheng Tan
SPSanjib KUMAR Panda
Sanjib KUMAR Panda
In this paper, a hybrid of indoor ambient light and thermal energy harvesting scheme that uses only one power management circuit to condition the combined output power harvested from both energy sources is proposed to extend the lifetime of the wireless sensor node. By avoiding the use of individual power management circuits for multiple energy sources, the number of components used in the hybrid energy harvesting (HEH) system is reduced and the system form factor, cost and power losses are thus reduced. An efficient microcontroller-based ultra low power management circuit with fixed voltage reference based maximum power point tracking is implemented with closed-loop voltage feedback control to ensure near maximum power transfer from the two energy sources to its connected electronic load over a wide range of operating conditions. From the experimental test results obtained, an average electrical power of 621 μW is harvested by the optimized HEH system at an average indoor solar irradiance of 1010 lux and a thermal gradient of 10 K, which is almost triple of that can be obtained with conventional single-source thermal energy harvesting method.

8 March 2004 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WQWeizhe Qian
Weizhe Qian
SPSanjib KUMAR Panda
Sanjib KUMAR Panda
JXJian-Xin Xu
Jian-Xin Xu
Parasitic torque pulsations exist in permanent magnet synchronous motors (PMSMs) due to nonsinusoidal flux density distribution around the air-gap, errors in current measurements, and variable magnetic reluctance of the air-gap due to stator slots. These torque pulsations vary periodically with rotor position and are reflected as speed ripple, which degrades the PMSM drive performance, particularly at low speeds. Because of the periodic nature of torque ripple, iterative learning control (ILC) is intuitively an excellent choice for torque ripple minimization. In this paper, first we propose an ILC scheme implemented in time domain to reduce periodic torque pulsations. A forgetting factor is introduced in this scheme to increase the robustness of the algorithm against disturbance. However, this limits the extent to which torque pulsations can be suppressed. In order to eliminate this limitation, a modified ILC scheme implemented in frequency domain by means of Fourier series expansion is presented. Experimental evaluations of both proposed schemes are carried out on a DSP-controlled PMSM drive platform. Test results obtained demonstrate the effectiveness of the proposed control schemes in reducing torque ripple by a factor of approximately three under various operating conditions.

11 March 2016 in IEEE Transactions on Power Electronics
Verified
Journal Article
Open access
JPJason Poon
Jason Poon
PJPalak Jain
Palak Jain
IKIoannis C. Konstantakopoulos
Ioannis C. Konstantakopoulos
CSCostas Spanos
Costas Spanos
SPSanjib KUMAR Panda
Sanjib KUMAR Panda
SSSeth R. Sanders
Seth R. Sanders
We present the analysis, design, and experimental validation of a model-based fault detection and identification (FDI) method for switching power converters using a model-based state estimator approach. The proposed FDI approach is general in that it can be used to detect and identify arbitrary faults in components and sensors in a broad class of switching power converters. The FDI approach is experimentally demonstrated on a nanogrid prototype with a 380-V dc distribution bus. The nanogrid consists of four different switching power converters, including a buck converter, an interleaved boost converter, a single-phase rectifier, and a three-phase inverter. We construct a library of fault signatures for possible component and sensor faults in all four converters. The FDI algorithm successfully achieves fault detection in under 400 $\mu$s and fault identification in under 10 ms for faults in each converter. The proposed FDI approach enables a flexible and scalable solution for improving fault tolerance and awareness in power electronics systems.

17 July 2013 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
DHDuc Chinh Hoang
Duc Chinh Hoang
PYParikshit Yadav
Parikshit Yadav
RKRajesh Kumar
Rajesh Kumar
SPSanjib KUMAR Panda
Sanjib KUMAR Panda
In real-life applications of wireless sensor networks (WSNs), optimization of the network operation is required to extend its lifetime. A framework is proposed that enables practical development of centralized cluster-based protocols supported by optimization methods for the WSNs. Based on this framework, a protocol using harmony search algorithm (HSA), a music-based meta-heuristic optimization method, is designed and implemented in real time for the WSNs. It is expected to minimize the intra-cluster distances between the cluster members and their cluster heads (CHs) and optimize the energy distribution of the WSNs. The study of HSA cluster-based protocol is carried out in a real case where the WSNs equipped with the proposed protocol are deployed in an indoor environment to monitor the ambient temperature for fire detection. A comparison is made with the well-known cluster-based protocols developed for WSNs such as low-energy adaptive clustering hierarchy-centralized (LEACH-C) and a cluster-based protocol using Fuzzy C-Means (FCM) clustering algorithm. Experimental results demonstrate that the proposed protocol using HSA can be realized in centralized cluster-based WSNs for safety and surveillance applications in building environments. From the obtained experimental test results, it can be seen that the WSNs lifetime has been extended using the proposed HSA protocol in comparison with that of LEACH-C and FCM protocols.

3 December 2010 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SDSouvik Dasgupta
Souvik Dasgupta
SSSanjib Kumar Sahoo
Sanjib Kumar Sahoo
SPSanjib KUMAR Panda
Sanjib KUMAR Panda
In this paper, a novel current control technique is proposed to control both active and reactive power flow from a renewable energy source feeding a microgrid system through a single-phase parallel-connected inverter. The parallel-connected inverter ensures active and reactive power flow from the grid with low-current total harmonic distortion even in the presence of nonlinear load. A p-q theory-based approach is used to find the reference current of the parallel-connected converter to ensure desired operating conditions at the grid terminal. The proposed current controller is simple to implement and gives superior performance over the conventional current controllers, such as rotating frame proportional-integral controller or stationary frame proportional resonant controller. The stability of the proposed controller is ensured by direct Lyapunov method. A new technique based on the spatial repetitive controller is also proposed to improve the performance of the current controller by estimating the grid and other periodic disturbances. Detailed experimental results are presented to show the efficacy of the proposed current control scheme along with the proposed nonlinear controller to control the active and reactive power flow in a single-phase microgrid under different operating conditions.