The electron affinity of carbon is measured on a beam of by photodetachment microscopy, with a precision increased by one order of magnitude with respect to the last measurement. Isotopes 12 and 13 are used in succession, which makes it possible to determine the isotope shift of the electron affinity of carbon. The obtained result, about , corroborates recent calculations of this shift. The electron affinities of and are and , i.e., and eV, respectively.
1 July 2021 in Plasma Sources Science and Technology
The two-photon excitation cross-section is a key parameter for the two-photon absorption laser induced fluorescence (TALIF) method, which is commonly used to measure atomic densities in gaseous media, especially for plasma diagnostics. The method consists in recording the fluorescence signal that follows the resonant absorption of two photons of UV light. Calibration often relies on comparing the signal recorded in the studied sample with the fluorescence produced, at a similar wavelength, in a noble gas vapor, the density of which can be easily known. The ratio of the involved cross-sections however plays an essential role for the accuracy of such measurements. Yet the two-photon excitation cross-section of atomic xenon, which is often used as the reference for oxygen density measurements, was measured only once, at the wavelengths of interest. The aim of the present study has been to consolidate the experimental value of that key parameter. The cross-section is found equal to and for the 6 p ′[3/2] 2 and 6 p ′[1/2] 0 levels, respectively. For the 6 p ′[3/2] 2 level this is more than twice smaller than previously admitted. Even though the necessarily large relative uncertainty of a non-linear cross-section attaches a relatively large uncertainty to this factor of one half, the result suggests that atomic densities already measured by Xe-calibrated TALIF may have to be revised to significantly lower values. The experiments performed also provide an opportunity to revisit the validity of the approximations used for quantitative TALIF measurements and the collisional broadening and pressure shift of the two-photon 6 p ′[1/2] 0 line. A new formula has been used to describe the two-photon absorption of a Gaussian beam in a long gas cell, which makes the decrease of the beam intensity a simple analytic expression even in strong absorption regime, based on a polylogarithmic function of the absorption rate variable.
27 February 2006 in Journal of Physics B: Atomic, Molecular and Optical Physics
A method is described to measure photoexcitation cross sections, relying on the expected behavior of the signal in the saturated regime, when excitation is provided by a Gaussian light beam. The method is implemented on a negative ion beam, with a single-mode pulsed Nd:YAG laser, to make a laser measurement of the photodetachment cross section of ${\mathrm{H}}^{$-${}}$, at the wavelength 1064 nm. This cross section is of importance both as a photodetachment cross section of the most elementary negative ion and as a key parameter for the production of fast neutral ${\mathrm{H}}^{0}$ or ${\mathrm{D}}^{0}$ atoms, by photodetachment of accelerated anions. The obtained value $4.5(6)\ifmmode\times\else\texttimes\fi{}{10}^{$-${}21}\phantom{\rule{0.16em}{0ex}}{\mathrm{m}}^{2}$ is greater than the one known from older measurements and most ab initio calculations.
The electron affinity eA(Se) of selenium is measured by photodetachment microscopy on a cesium-sputtering-produced Se$-${} ion beam using a single-mode CW dye laser. The measured value of the electron affinity is 16297.276(9)cm$-${}1, or 2.020~604~6(11) eV, which improves the accuracy of this atomic quantity by a factor of 60.