The nano-crystalline films of zirconium nitride have been synthesized on implants for trauma surgery made of AISI 316 L stainles steel by using vacuum-arc deposition under RF-biasing mode in “Bulat” type device. Structure examinations – X-ray diffraction analysis (XRD), X-ray fluoriscent analysis (XRF), scanning electron microscopy (SEM) with microanalysis (EDX), nanoidentation method – were performed to study phase and chemical composition, surface morphology, microstructure and nanohardness of ZrN coatings. The corrosion resistance of coatings has been tested in 0.9 % quasiphysiological NaCl solution.
19 August 2024 in Problems of Atomic Science and Technology
A prototype of plasma sterilizer based on dielectric barrier discharge (DBD) with additional ultrasonic cavitation for cold sterilization has been developed. It provides sterilization of reusable small dental instruments, and components made from corrosion-resistant metals and alloys (stainless steel, titanium, etc.), as well as surgical instruments, implants, small drills, plastic sundries, ozone resistant medical rubbers (silicone, etc.), polymers, epoxy resins and glass. The sterilizer is well suited for dentistry and can be used in medical, sanatorium, outpatient and other medical institutions, as well as in military field surgery. The volume of the sterilization bath is 2.5 l. The ozone concentration at the output of the ozone generator is 35…52 mg/l, the ozone concentration in the sterilizer chamber is 6.5…8 mg/l, depending on the water temperature and its volume in the bath. The dependence of the increase of ozone concentration in water on time at different oxygen flow rates is monitored.
19 March 2023 in Problems of Atomic Science and Technology
Water purification from ammonium hydroxide was carried out by using two methods of processing: treatment with ozone generated by a dielectric barrier discharge (DBD) as well as processing in plasma-chemical reactor equipped with a water electrode and a diaphragm, where the main oxidation factors were OH hydroxyl radicals. The volume of the treated aqueous solution was 300 ml and the NH4OH concentration was 0.025 ml in both cases. The phenolphthalein test was used for visual analysis of the content of an aqueous solution of ammonia in water. The ozone concentration was about 5.8 mg/l in water with ozone injection from an ozone generator and 0.7 mg/l in a plasma-chemical reactor, respectively. The analysis of OH and NO radicals in the water-air gap of the plasmachemical reactor was carried out using a spectrometer operated in the range of 200...800 nm.
11 April 2024 in Problems of Atomic Science and Technology