Mark Melnykowycz

Dr. Mark Melnykowycz

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MMMark Melnykowycz
Mark Melnykowycz
BKBirgit Koll
Birgit Koll
DSDagobert Scharf
Dagobert Scharf
FCFrank Clemens
Frank Clemens
The development of flexible polymer monofilament fiber strain sensors have many applications in both wearable computing (clothing, gloves, etc.) and robotics design (large deformation control). For example, a high-stretch monofilament sensor could be integrated into robotic arm design, easily stretching over joints or along curved surfaces. As a monofilament, the sensor can be woven into or integrated with textiles for position or physiological monitoring, computer interface control, etc. Commercially available conductive polymer monofilament sensors were tested alongside monofilaments produced from carbon black (CB) mixed with a thermo-plastic elastomer (TPE) and extruded in different diameters. It was found that signal strength, drift, and precision characteristics were better with a 0.3 mm diameter CB/TPE monofilament than thick (~2 mm diameter) based on the same material or commercial monofilaments based on natural rubber or silicone elastomer (SE) matrices.

1 December 2009 in Composites Science and Technology
Verified
Journal Article
Closed access
RMRyosuke Matsuzaki
Ryosuke Matsuzaki
MMMark Melnykowycz
Mark Melnykowycz
ATAkira Todoroki
Akira Todoroki

19 January 2006 in Smart Materials and Structures
Verified
Journal Article
Closed access
MMMark Melnykowycz
Mark Melnykowycz
XKX Kornmann
X Kornmann
CHC Huber
C Huber
MBM Barbezat
M Barbezat
ABA J Brunner
A J Brunner

23 March 2009 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
PDF file
ABAndreas J. Brunner
Andreas J. Brunner
MBMarcel Birchmeier
Marcel Birchmeier
MMMark Melnykowycz
Mark Melnykowycz
MBMichel Barbezat
Michel Barbezat
Piezoelectric Active Fiber Composites (AFC) and Macro Fiber Composites (MFC) have the potential to provide various sensor functions for nondestructive test methods. AFC have been integrated into fiber-reinforced laminates as a first step towards structures with sensing capability. These developments constitute initial stages for developing adaptive composite structures or structures with integrated health monitoring system. So far, the use of AFC and MFC has been explored in selected nondestructive tests for defect detection in model composite systems on laboratory scale with e.g., Acoustic Emission, Acousto-Ultrasonics, and Electromechanical Impedance testing. The present article will focus on limitations and current prospects for structural health monitoring with AFC or MFC and discuss selected concepts and approaches.

17 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SMSwati Mandekar
Swati Mandekar
AHAbigail Holland
Abigail Holland
MTMoritz Thielen
Moritz Thielen
MBMehdi Behbahani
Mehdi Behbahani
MMMark Melnykowycz
Mark Melnykowycz
Wearable EEG has gained popularity in recent years driven by promising uses outside of clinics and research. The ubiquitous application of continuous EEG requires unobtrusive form-factors that are easily acceptable by the end-users. In this progression, wearable EEG systems have been moving from full scalp to forehead and recently to the ear. The aim of this study is to demonstrate that emerging ear-EEG provides similar impedance and signal properties as established forehead EEG. EEG data using eyes-open and closed alpha paradigm were acquired from ten healthy subjects using generic earpieces fitted with three custom-made electrodes and a forehead electrode (at Fpx) after impedance analysis. Inter-subject variability in in-ear electrode impedance ranged from 20 kΩ to 25 kΩ at 10 Hz. Signal quality was comparable with an SNR of 6 for in-ear and 8 for forehead electrodes. Alpha attenuation was significant during the eyes-open condition in all in-ear electrodes, and it followed the structure of power spectral density plots of forehead electrodes, with the Pearson correlation coefficient of 0.92 between in-ear locations ELE (Left Ear Superior) and ERE (Right Ear Superior) and forehead locations, Fp1 and Fp2, respectively. The results indicate that in-ear EEG is an unobtrusive alternative in terms of impedance, signal properties and information content to established forehead EEG.

4 March 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MMMark Melnykowycz
Mark Melnykowycz
MTMichael Tschudin
Michael Tschudin
FCFrank Clemens
Frank Clemens
A soft condensed matter sensor (SCMS) designed to measure strains on the human body is presented. The hybrid material based on carbon black (CB) and a thermoplastic elastomer (TPE) was bonded to a textile elastic band and used as a sensor on the human wrist to measure hand motion by detecting the movement of tendons in the wrist. Additionally it was able to track the blood pulse wave of a person, allowing for the determination of pulse wave peaks corresponding to the systole and diastole blood pressures in order to calculate the heart rate. Sensor characterization was done using mechanical cycle testing, and the band sensor achieved a gauge factor of 4–6.3 while displaying low signal relaxation when held at a strain levels. Near-linear signal performance was displayed when loading to successively higher strain levels up to 50% strain.