Per Rugaard Poulsen

Prof. Per Rugaard Poulsen

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
JBJenny Bertholet
Jenny Bertholet
AKAntje-Christin Knopf
Antje-Christin Knopf
BEBjörn Eiben
Björn Eiben
JMJamie R McClelland
Jamie R McClelland
AGAlexander Grimwood
Alexander Grimwood
UOUwe Oelfke
Uwe Oelfke
Radiotherapy (RT) aims to deliver a spatially conformal dose of radiation to tumours while maximizing the dose sparing to healthy tissues. However, the internal patient anatomy is constantly moving due to respiratory, cardiac, gastrointestinal and urinary activity. The long term goal of the RT community to ‘see what we treat, as we treat’ and to act on this information instantaneously has resulted in rapid technological innovation. Specialized treatment machines, such as robotic or gimbal-steered linear accelerators (linac) with in-room imaging suites, have been developed specifically for real-time treatment adaptation. Additional equipment, such as stereoscopic kilovoltage (kV) imaging, ultrasound transducers and electromagnetic transponders, has been developed for intrafraction motion monitoring on conventional linacs. Magnetic resonance imaging (MRI) has been integrated with cobalt treatment units and more recently with linacs. In addition to hardware innovation, software development has played a substantial role in the development of motion monitoring methods based on respiratory motion surrogates and planar kV or Megavoltage (MV) imaging that is available on standard equipped linacs. In this paper, we review and compare the different intrafraction motion monitoring methods proposed in the literature and demonstrated in real-time on clinical data as well as their possible future developments. We then discuss general considerations on validation and quality assurance for clinical implementation. Besides photon RT, particle therapy is increasingly used to treat moving targets. However, transferring motion monitoring technologies from linacs to particle beam lines presents substantial challenges. Lessons learned from the implementation of real-time intrafraction monitoring for photon RT will be used as a basis to discuss the implementation of these methods for particle RT.

23 January 2014 in Medical Physics
Verified
Journal Article
Open access
PDF file
PKPaul J. Keall
Paul J. Keall
ECEmma Colvill
Emma Colvill
RORicky O’bRien
Ricky O’bRien
JNJin Aun Ng
Jin Aun Ng
PPPer Rugaard Poulsen
Per Rugaard Poulsen
JBJeremy T. Booth
Jeremy T. Booth
Purpose:: We report on the clinical process, quality assurance, and geometric and dosimetric results of the first clinical implementation of electromagnetic transponder‐guided MLC tracking which occurred on 28 November 2013 at the Northern Sydney Cancer Centre.Methods:: An electromagnetic transponder‐based positioning system (Calypso) was modified to send the target position output to in‐house‐developed MLC tracking code, which adjusts the leaf positions to optimally align the treatment beam with the real‐time target position. Clinical process and quality assurance procedures were developed and performed. The first clinical implementation of electromagnetic transponder‐guided MLC tracking was for a prostate cancer patient being treated with dual‐arc VMAT (RapidArc). For the first fraction of the first patient treatment of electromagnetic transponder‐guided MLC tracking we recorded the in‐room time and transponder positions, and performed dose reconstruction to estimate the delivered dose and also the dose received had MLC tracking not been used.Results:: The total in‐room time was 21 min with 2 min of beam delivery. No additional time was needed for MLC tracking and there were no beam holds. The average prostate position from the initial setup was 1.2 mm, mostly an anterior shift. Dose reconstruction analysis of the delivered dose with MLC tracking showed similar isodose and target dose volume histograms to the planned treatment and a 4.6% increase in the fractional rectal V60. Dose reconstruction without motion compensation showed a 30% increase in the fractional rectal V60 from that planned, even for the small motion.Conclusions:: The real‐time beam‐target correction method, electromagnetic transponder‐guided MLC tracking, has been translated to the clinic. This achievement represents a milestone in improving geometric and dosimetric accuracy, and by inference treatment outcomes, in cancer radiotherapy.

1 July 2009 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
BCByungchul Cho
Byungchul Cho
PPPer R. Poulsen
Per R. Poulsen
ASAlex Sloutsky
Alex Sloutsky
Amit SawantAmit Sawant
Amit Sawant
PKPaul J. Keall
Paul J. Keall

25 September 2012 in Medical Physics
Verified
Journal Article
Closed access
PPPer Rugaard Poulsen
Per Rugaard Poulsen
MSMai Lykkegaard Schmidt
Mai Lykkegaard Schmidt
PKPaul Keall
Paul Keall
EWEsben Schjødt Worm
Esben Schjødt Worm
WFWalther Fledelius
Walther Fledelius
LHLone Hoffmann
Lone Hoffmann

1 December 2012 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
JNJin Aun Ng
Jin Aun Ng
JBJeremy T. Booth
Jeremy T. Booth
PPPer R. Poulsen
Per R. Poulsen
WFWalther Fledelius
Walther Fledelius
EWEsben Schjødt Worm
Esben Schjødt Worm
PKPaul J. Keall
Paul J. Keall

1 June 2009 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
Amit SawantAmit Sawant
Amit Sawant
RSRyan L. Smith
Ryan L. Smith
RVRaghu B. Venkat
Raghu B. Venkat
LSLakshmi Santanam
Lakshmi Santanam
BCByungchul Cho
Byungchul Cho
PKPaul J. Keall
Paul J. Keall