The objective of this study is to investigate the effect of multiple dead elements in an ultrasound probe on the accuracy of Doppler ultrasound measurements. For this work, we used a specially designed ultrasound imaging system, the Ultrasonix Sonix RP, that provides the user with the ability to disable selected elements in the probe. Using fully functional convex, linear, and phased array probes, we established a performance baseline by measuring the parameters of a laminar parabolic flow profile. These same parameters were then measured using probes with 1 to 10 disabled elements. The acquired velocity spectra from the functional probes and the probes with disabled elements were then analyzed to determine the overall Doppler power, maximum flow velocity, and average flow velocity. Color Flow Doppler images were also evaluated in a similar manner. The analysis of the Doppler spectra indicates that the overall Doppler power as well as the detected maximum and average velocities decrease with the increasing number of disabled elements. With multiple disabled elements, decreases in the detected maximum and average velocities greater than 20% were recorded. Similar results were also observed with Color Flow Doppler measurements. Our results confirmed that the degradation of the ultrasound probe through the loss of viable elements will negatively affect the quality of the Doppler-derived diagnostic information. We conclude that the results of Doppler measurements cannot be considered accurate or reliable if there are four or more contiguous dead elements in any given probe.
Aim. To evaluate the prognostic value of ultrasound and shear-wave elastography (SWE) in diagnosing malignant cervical lymph nodes. Methods. A total of 99 patients with enlarged lymph nodes (99 lymph nodes presenting as a neck mass) were examined clinically with conventional ultrasound including Doppler examination and shear-wave elastography. The results of the examinations were compared with the final diagnosis. Results. There were 43 benign and 56 malignant lymph nodes in our cohort. Age and sex were significant predictors of malignancy. The standard ultrasound parameters—node size, long/short axis ratio, hilum, vascularization, and the presence of microcalcifications—were also statistically significant. Lymph node volume combined with age showed the best predictive power. The maximum stiffness found on SWE was also a significant predictor of malignancy. The combination of epidemiologic, classic ultrasound, and elastographic parameters yielded the highest sensitivity and specificity in the prediction of malignancy; however, the additional impact of elastographic parameters was low. Conclusion. A combination of epidemiologic and classic ultrasound parameters can discriminate between malignant and benign lymph nodes with satisfactory sensitivity and specificity. Examining the stiffness of lymph nodes by means of SWE does not add much new predictive power.