Junsheng Wang

Dr. Junsheng Wang

College of Information and Science Technology, Dalian Maritime University, Dalian 116026, China
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2020 in The Analyst
Verified
Journal Article
Closed access
PDF file
CCChen Chen
Chen Chen
Junsheng WangJunsheng Wang
Junsheng Wang
Optical biosensors have exhibited worthwhile performance in detecting biological systems and promoting significant advances in clinical diagnostics, drug discovery, food process control, and environmental monitoring.

1 March 2022 in Environmental Pollution
Verified
Journal Article
Closed access
Kai ZhaoKai Zhao
Kai Zhao
YWYunman Wei
Yunman Wei
JDJianhong Dong
Jianhong Dong
PZPenglu Zhao
Penglu Zhao
YWYuezhu Wang
Yuezhu Wang
Junsheng WangJunsheng Wang
Junsheng Wang

26 November 2013 in Sensors
Verified
Journal Article
Open access
PDF file
Junsheng WangJunsheng Wang
Junsheng Wang
JSJinyang Sun
Jinyang Sun
YSYongxin Song
Yongxin Song
YXYongyi Xu
Yongyi Xu
XPXinxiang Pan
Xinxiang Pan
DLDongqing Li
Dongqing Li
Detection of living microalgae cells is very important for ballast water treatment and analysis. Chlorophyll fluorescence is an indicator of photosynthetic activity and hence the living status of plant cells. In this paper, we developed a novel microfluidic biosensor system that can quickly and accurately detect the viability of single microalgae cells based on chlorophyll fluorescence. The system is composed of a laser diode as an excitation light source, a photodiode detector, a signal analysis circuit, and a microfluidic chip as a microalgae cell transportation platform. To demonstrate the utility of this system, six different living and dead algae samples (Karenia mikimotoi Hansen, Chlorella vulgaris, Nitzschia closterium, Platymonas subcordiformis, Pyramidomonas delicatula and Dunaliella salina) were tested. The developed biosensor can distinguish clearly between the living microalgae cells and the dead microalgae cells. The smallest microalgae cells that can be detected by using this biosensor are 3 μm ones. Even smaller microalgae cells could be detected by increasing the excitation light power. The developed microfluidic biosensor has great potential for in situ ballast water analysis.

1 January 2025 in Journal of Materials Chemistry A
Verified
Journal Article
Open access
PDF file
JLJianqiao Liu
Jianqiao Liu
DZDan Zhao
Dan Zhao
XWXian Wu
Xian Wu
DWDi Wu
Di Wu
NSNingning Su
Ningning Su
QZQianru Zhang
Qianru Zhang
Synergistic dual-defect engineering in Nb-doped SnO 2 QDs boosts visible-light photocatalysis by creating oxygen vacancies, narrowing bandgaps, and extending carrier lifetimes, enabling efficient degradation of PE microplastics in real-world water.

17 November 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Ran PengRan Peng
Ran Peng
TZTingting Zhang
Tingting Zhang
Sheng YanSheng Yan
Sheng Yan
YSYongxin Song
Yongxin Song
Xinyu LiuXinyu Liu
Xinyu Liu
Junsheng WangJunsheng Wang
Junsheng Wang
Surface-enhanced Raman scattering (SERS) is a cutting-edge technique for highly sensitive analysis of chemicals and molecules. Traditional SERS-active nanostructures are constructed on rigid substrates where the nanogaps providing hot-spots of Raman signals are fixed, and sample loading is unsatisfactory due to the unconformable attachment of substrates on irregular sample surfaces. A flexible SERS substrate enables conformable sample loading and, thus, highly sensitive Raman detection but still with limited detection capabilities. Stretchable SERS substrates with flexible sample loading structures and controllable hot-spot size provide a new strategy for improving the sample loading efficiency and SERS detection sensitivity. This review summarizes and discusses recent development and applications of the newly conceptual stretchable SERS substrates. A roadmap of the development of SERS substrates is reviewed, and fabrication techniques of stretchable SERS substrates are summarized, followed by an exhibition of the applications of these stretchable SERS substrates. Finally, challenges and perspectives of the stretchable SERS substrates are presented. This review provides an overview of the development of SERS substrates and sheds light on the design, fabrication, and application of stretchable SERS systems.

14 September 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Kai ZhaoKai Zhao
Kai Zhao
PZPenglu Zhao
Penglu Zhao
JDJianhong Dong
Jianhong Dong
YWYunman Wei
Yunman Wei
BCBin Chen
Bin Chen
Junsheng WangJunsheng Wang
Junsheng Wang
Identification of circulating tumor cells (CTCs) from a majority of various cell pools has been an appealing topic for diagnostic purposes. This study numerically demonstrates the isolation of CTCs from blood cells by the combination of dielectrophoresis and magnetophoresis in a microfluidic chip. Taking advantage of the label-free property, the separation of red blood cells, platelets, T cells, HT-29, and MDA-231 was conducted in the microchannel. By using the ferromagnet structure with double segments and a relatively shorter distance in between, a strong gradient of the magnetic field, i.e., sufficiently large MAP forces acting on the cells, can be generated, leading to a high separation resolution. In order to generate strong DEP forces, the non-uniform electric field gradient is induced by applying the electric voltage through the microchannel across a pair of asymmetric orifices, i.e., a small orifice and a large orifice on the opposite wall of the channel sides. The distribution of the gradient of the magnetic field near the edge of ferromagnet segments, the gradient of the non-uniform electric field in the vicinity of the asymmetric orifices, and the flow field were investigated. In this numerical simulation, the effects of the ferromagnet structure on the magnetic field, the flow rate, as well as the strength of the electric field on their combined magnetophoretic and dielectrophoretic behaviors and trajectories are systemically studied. The simulation results demonstrate the potential of both property- and size-based cell isolation in the microfluidic device by implementing magnetophoresis and dielectrophoresis.