Joana Barros

Dr. Joana Barros

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2020 in Acta Obstetricia et Gynecologica Scandinavica
Verified
Journal Article
Closed access
PDF file
JBJoana Barros
Joana Barros
MAMaria Afonso
Maria Afonso
AMAna T. Martins
Ana T. Martins
ACAna I. Carita
Ana I. Carita
NCNuno Clode
Nuno Clode
LGLuís M. Graça
Luís M. Graça

1 April 2022 in American Journal of Obstetrics and Gynecology
Verified
Journal Article
Closed access
FBFederica Bellussi
Federica Bellussi
DMDaniele Di Mascio
Daniele Di Mascio
GSGinevra Salsi
Ginevra Salsi
TGTullio Ghi
Tullio Ghi
ADAndrea Dall'Asta
Andrea Dall'Asta
VBVincenzo Berghella
Vincenzo Berghella

29 April 2016 in Acta Medica Portuguesa
Verified
Journal Article
Open access
PDF file
JBJoana Barros
Joana Barros
NCNuno Clode
Nuno Clode
LGLuís M. Graça
Luís M. Graça
Introduction: Late preterm birth (defined as birth between 34 and 36 complete weeks’ gestation) and early term birth (defined as birth between 37 and 38 complete weeks’ gestation) have become a topic of recent discussion as the morbidity associated with delivery at these gestational ages has become increasingly evident. Our objective was to evaluate the characteristics of late preterm and early term birth in Portugal. Material and Methods: We developed a survey questionnaire that was sent to the Obstetric Department of all public hospitals in Portugal. The questionnaire consisted on questions on prevalence and mode of delivery of late preterm and early term period and associated neonatal morbidity and mortality. The questions referred solely to single births occurred during 2013. Results: We received completed questionnaires from 14 hospitals, corresponding to nearly one third (33.5%) of total deliveries in Portugal. We report 5.4% of late preterm and 27% of early term deliveries. Approximately two thirds of late preterm and three quarters of early term deliveries were spontaneous. The cesarean section rate was higher in late preterm (39.1%) than in early term (26.4%) births. Neonatal complications were more frequent in late preterm neonates (34.2%) when compared to early term neonates (14.2%). Discussion: The prevalence of late preterm and early term birth in our cohort is comparable, although slightly reduced, to other published series. Conclusion: The obstetric community should raise efforts to limit deliveries below 39 weeks’ gestation to the ones with a valid medical indication.

22 February 2011 in International Journal of Gynecology & Obstetrics
Verified
Journal Article
Closed access
JBJoana Barros
Joana Barros
IRInês Reis
Inês Reis
LGLuís M. Graça
Luís M. Graça

19 December 2022 in Fetal Diagnosis and Therapy
Verified
Journal Article
Closed access
PDF file
CPCatarina Policiano
Catarina Policiano
JMJorge M. Mendes
Jorge M. Mendes
AFAndreia Fonseca
Andreia Fonseca
JBJoana Barros
Joana Barros
SVSara Vargas
Sara Vargas
LGLuis M. Graca
Luis M. Graca
Introduction: The aim of this study was to evaluate the accuracy of 35–37 weeks’ ultrasound for fetal growth restriction (FGR) detection and the impact of 30th–33rd weeks versus 30th–33rd and 35th–37th weeks’ ultrasound on perinatal outcomes. Methods: This was a randomized controlled trial that enrolled 1,061 low-risk pregnant women: 513 in the control group (routine ultrasound performed at 30th–33rd weeks) and 548 in the study group (with an additional ultrasound at 35th–37th weeks). FGR was defined as a fetus with an estimated fetal weight (EFW) below the 10th percentile. p values < 0.05 were considered statistically significant. Results: The ultrasound at 35–37 weeks had an overall accuracy of FGR screening of 94%. Spearman’s correlation coefficient between EFW and birthweight centile was higher for at 35–37 weeks’ ultrasound (ρ = 0.75) compared with 30–33 weeks’ ultrasound (ρ = 0.44). The study group had a lower rate of operative vaginal deliveries (24.4% vs. 39.3%, p = 0.005) and cesarean deliveries for nonreassuring fetal status (16.8% vs. 38.8%, p < 0.001). Discussion/Conclusion: A later ultrasound (35–37 weeks) had a high accuracy for detection of FGR and had a higher correlation between EFW and birthweight centiles. Furthermore, it was also associated with lower adverse perinatal outcomes compared to an earlier ultrasound.

30 December 2015 in Revista Brasileira de Ginecologia e Obstetrícia
Verified
Journal Article
Open access
PDF file
IRInês Reis
Inês Reis
IPIsabel Pereira
Isabel Pereira
NCNuno Clode
Nuno Clode
LGLuís M. Graça
Luís M. Graça
JBJoana Barros
Joana Barros
Objective To evaluate the accuracy of fetal weight prediction by ultrasonography labor employing a formula including the linear measurements of femur length (FL) and mid-thigh soft-tissue thickness (STT). Methods We conducted a prospective study involving singleton uncomplicated term pregnancies within 48 hours of delivery. Only pregnancies with a cephalic fetus admitted in the labor ward for elective cesarean section, induction of labor or spontaneous labor were included. We excluded all non-Caucasian women, the ones previously diagnosed with gestational diabetes and the ones with evidence of ruptured membranes. Fetal weight estimates were calculated using a previously proposed formula [estimated fetal weight = − 1687.47 + (54.1 × FL) + (76.68 × STT). The relationship between actual birth weight and estimated fetal weight was analyzed using Pearson's correlation. The formula's performance was assessed by calculating the signed and absolute errors. Mean weight difference and signed percentage error were calculated for birth weight divided into three subgroups: < 3000 g; 3000–4000g; and > 4000 g. Results We included for analysis 145 cases and found a significant, yet low, linear relationship between birth weight and estimated fetal weight (p < 0.001; R2 = 0.197) with an absolute mean error of 10.6%. The lowest mean percentage error (0.3%) corresponded to the subgroup with birth weight between 3000 g and 4000 g. Conclusions This study demonstrates a poor correlation between actual birth weight and the estimated fetal weight using a formula based on femur length and mid-thigh soft-tissue thickness, both linear parameters. Although avoidance of circumferential ultrasound measurements might prove to be beneficial, it is still yet to be found a fetal estimation formula that can be both accurate and simple to perform. Objetivo Avaliar a precisão da determinação ultrassonográfica da estimativa de peso fetal recorrendo apenas a parâmetros lineares (comprimento do fémur – FL - e espessura de tecido mole a meio da coxa fetal - STT), no período precedente ao parto. Métodos Realizamos um estudo prospectivo que incluiu gestações simples de termo, com feto cefálico, nas quais o parto ocorreu nas 48h seguintes à avaliação ecográfica. A inclusão no estudo foi feita no momento de admissão ao bloco de partos para cesariana eletiva, indução do trabalho de parto ou trabalho de parto espontâneo. Foram excluídas todas as grávidas não caucasianas, com diagnóstico de diabetes gestacional ou evidência de rotura de membranas. A estimativa de peso fetal foi calculada através de uma fórmula previamente publicada [estimativa de peso fetal = − 1687,47 + (54,1 × FL) + (76,68 × STT). A relação entre o peso real e o peso estimado foi analisada através da correlação de Pearson. O desempenho desta fórmula foi avaliado através do cálculo da percentagem de erro absoluto e não absoluto. Os recém-nascidos foram divididos em 3 grupos consoante o peso real: < 3000 g; 3000 g – 4000 g; e > 4000 g; para cada grupo foi calculada diferença média entre a estimativa de peso e o peso real e a percentagem de erro associada. Resultados Incluímos 145 casos no estudo, cuja estimativa de peso e peso real se correlacionaram significativamente, apesar do valor de correlação ser pouco elevado (p < 0,001; R2 = 0,197). Globalmente, a percentagem de erro absoluto foi 10,6%. A percentagem de erro mais baixa correspondeu ao grupo com peso real entre 3000 g e 4000 g. Conclusões Com este estudo demonstramos uma correlação fraca entre o peso real e a estimativa de peso fetal ultrassonográfica, quando calculada com base numa fórmula que usa o comprimento do fémur e a espessura de tecido mole a meio da coxa fetal, ambos parâmetros lineares. Ainda que a exclusão de parâmetros circunferenciais no cálculo da estimativa de peso fetal se venha a provar benéfica, esta não parece ser uma fórmula simultaneamente simples e precisa no cálculo da estimativa de peso fetal.