Tobias Reynolds

Tobias Reynolds

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
SSSam Soufi
Sam Soufi
ADAubrey L. Diller
Aubrey L. Diller
KDKathleen Dungan
Kathleen Dungan
CSCatherine Stanger
Catherine Stanger
AHAnna Hewitt
Anna Hewitt
TBTimothy E. Burdick
Timothy E. Burdick
Objective: Glucagon-like peptide-1 receptor agonists (GLP-1RAs) produce marked weight loss. A meaningful proportion of that loss is lean tissue including muscle, and the effects of GLP-1RAs on bone remain uncertain. Older adults are vulnerable to morbidity and mortality caused by muscle and bone density loss, and body weight alone cannot detect these changes. This narrative literature review evaluated body composition assessment methods for monitoring older adults receiving GLP-1RAs. Methods: PubMed was searched from inception to August 2026. Studies were included if they evaluated the accuracy, repeatability, or ability to detect change of a body composition assessment method in adults. Methods were grouped as reference-standard, clinically accessible, or emerging scalable technologies. Results: Thirteen studies were included (nine primary studies and four reviews or methodological guides). Two primary studies enrolled older adults, and one measured body composition during GLP-1RA treatment. Dual-energy X-ray absorptiometry (DXA) was the most practical reference method because it assesses lean mass, fat mass, and bone mineral density in one scan, but its precision declined with obesity and estimates differed between systems. Bioelectrical impedance analysis was highly repeatable, but accuracy varied widely between devices. Smartphone applications and three-dimensional optical imaging were the most scalable, but their apparent accuracy depended on the reference system and participant posture, and neither has been validated in older adults or for tracking change. None of the accessible or emerging methods measured bone. Conclusions: No current method is both valid and scalable for monitoring body composition in older adults receiving GLP-1RAs. Longitudinal validation in this population, with agreement reported on change scores, is needed before monitoring-guided care can be tested.

16 June 2026 in medRxiv
Verified
Preprint
Open access
PDF file
TRTobias Reynolds
Tobias Reynolds
JGJackson Gerard
Jackson Gerard
AJAydan Jordan
Aydan Jordan
NSNathan Streby
Nathan Streby
BSBrynlee Stoll
Brynlee Stoll
Madison Lee KackleyMadison Lee Kackley
Madison Lee Kackley
Introduction: Body composition, rather than body weight alone, is an increasingly important health metric, and preservation of lean mass has become a central concern in obesity treatment, aging, and chronic disease management. Dual-energy X-ray absorptiometry (DXA) provides accurate assessment of fat and lean tissue, but its cost and logistical requirements limit repeated measurement. Computer-vision approaches show promise for estimating adiposity from smartphone images, but lean-mass estimation remains less established. Methods: We evaluated a computer-vision body composition model, applied to consumer-grade smartphone photographs, against DXA in a held-out validation sample of 195 adults from an ongoing cross-sectional study. Body fat percentage and total lean mass percentage were co-primary outcomes; for total lean mass percentage, an image-only configuration (no added covariates) was pre-specified as primary. Agreement was quantified using Lin’s concordance correlation coefficient (CCC) as the lead statistic, with Pearson correlation, mean absolute error, root mean square error, mean bias, and Bland-Altman limits of agreement. In secondary analyses, appendicular lean mass and total lean mass percentage were each estimated with and without routine anthropometric and demographic inputs (body weight, height, age, and sex). Results: Total lean mass percentage agreed with DXA from image features alone (CCC 0.916). Body fat percentage, estimated with routine inputs added, agreed at least as closely (CCC 0.930). Adding routine inputs barely changed agreement for total lean mass percentage but markedly improved it for appendicular lean mass, an absolute quantity that scales with body size. Conclusions: A smartphone-image-based model estimated both body fat and lean mass with strong agreement to DXA, with lean mass percentage from image features alone. The approach needs no fixed equipment or ionizing radiation. Whether it can track change over time, including in incretin-based weight loss where lean mass preservation is a concern, was not assessed in this cross-sectional study. Author summary: Fat and muscle content in a person explains more about their health than weight alone, but the most accurate way to measure body composition requires specialized scanning equipment that is vastly inaccessible. We tested whether smartphone photographs could be used in an artificial-intelligence model to estimate body fat and muscle in a way that agrees with such medical scans. In a group of 195 adults, estimates from smartphone photographs agreed closely with the scan for both body fat and muscle. Measuring muscle this way is the more novel result, because earlier smartphone studies focused mostly on body fat, and monitoring muscle loss is becoming increasingly important with newer diabetes and weight-loss medications. We also looked at how much a few simple pieces of routine information, a person’s weight, height, age, and sex, changed the estimates. Adding this information made little difference when we expressed muscle as a share of the body, but helped substantially when we expressed muscle as an absolute amount, because absolute muscle tracks closely with overall body size. These results suggest a smartphone could make body composition easier to measure regularly, though more research is needed in larger and more diverse groups before it can become standard.