This article investigates the power quality enhancement of a grid-tied photovoltaic (PV) distribution system by employing a fuzzy logic proportional-integrator-derivative multiple complex coefficient filter multiple second-order generalized integrator frequency-locked loop (FLPID-MCCF-MSOGI-FLL) hybrid control scheme based shunt active power filter. The MSOGI-FLL reference current generation strategy is implemented to mitigate the current harmonics by extracting the fundamental constituents (FCs) from the nonlinear load currents, whereas an MCCF is employed to separate the FC from the distorted grid voltages and eliminates the voltage harmonics during extremely polluted grid voltage condition. The main objective of using FLPID is to maintain the stable power between dc and ac sides by regulating the dc-link voltage constant under transient conditions. To track the maximum power from the PV panel under varying environmental condition, the particle swarm optimization based perturb and observe technique is used in this article. The comparative analysis is analyzed to check the effectiveness of the proposed hybrid control scheme with existing and adaptive control techniques in respect of power quality, better dc offset rejection, better FC and frequency extraction, and grid synchronization. The system with the proposed control scheme is simulated on MATLAB/Simulink and validated in a real-time field-programmable gate array platform under different test scenarios. In conclusion, the harmonic content of grid currents and voltages is found well within the IEEE-519 standard limits.
Fiber Optic Gyroscope (FOG) is a key component in Inertial Navigation System. The performance of FOG degrades due to different types of random errors in the measured signal. Although Kalman filter and its variants like Sage-Husa Kalman filters are being used to denoise the Gyroscope signal the performance of Kalman filter is limited by the initial values of measurement and process noise covariance matrix, and transition matrix. To address this problem, this paper uses modified Sage-Husa adaptive Kalman filter to denoise the FOG signal. In this work, the random error of fiber optic gyroscope is modeled using a first order auto regressive (AR) model and used the coefficients of the model to initialize the transition matrix of Sage-Husa Adaptive Kalman filter. Allan variance analysis is used to quantify the random errors of the measured and denoised signal. The performance of proposed algorithm is compared with conventional Kalman filter and the simulation results show that the modified SageHusa adaptive Kalman filter (SHAKF) algorithm outperforms the conventional Kalman filter technique while denoising FOG signal.
4 July 2017 in IEEE Transactions on Industrial Informatics
This paper presents an analytical study and hardware-in-loop (HIL) cosimulation design of a grid-connected inverter system with a combinational robust observer-based modified repetitive current controller. In this study, main attention is paid to improve power quality and tracking performance of a distributed generation (DG) interfacing system under various perturbations. The inherent delay in convergence of conventional repetitive controller (RC) is reduced by introducing a low pass filter in delay line and this configuration is named as modified RC (MRC). By adding an observer with MRC, system states can be reconstructed, which improve the system dynamic response. Robust stability and convergence criterion are derived in terms of linear matrix inequality using combined Lyapunov function and singular value decomposition technique, which determine the suitable parameters of feedback control and state observer gains. By utilizing these gains, the switching signals are generated to operate the DG interfacing inverter effectively. The performance of proposed controller is compared with traditional proportional integral, proportional resonant, and MRC under both normal and fault conditions. Finally, HIL cosimulation is performed by realizing the power circuit in MATLAB/Simulink as a simulation model and a control structure using Xilinx system generator platform as burnt in hardware Virtex-6 field programmable gate array (FPGA) ML605 evaluation kit.
In this article, an advanced reference current generator employing a combination of novel dual multi-layer fifth-order generalized integrator and adaptive differentiation frequency locked loop scheme (DMFOGI-dFLL) is proposed for mitigation of harmonics present in a grid-tied photovoltaic (PV) system. The proposed DMFOGI reference current generator is utilized to separate the fundamental constituents from grid voltage distortions, sag, swell, unbalance, frequency variation, and dc offset conditions. In addition, a dFLL is implemented to estimate the system frequency adaptively at grid transient conditions, which is fed as feedback to the pre-filtering unit. Similarly, a fuzzy tuned proportional integral derivative (FPID) voltage controller is incorporated in the proposed controller to maintain the power balance between dc and ac sides by controlling the dc-link voltage. An incremental conductance (IC) control technique is additionally utilized to generate maximum power from the PV source through a boost converter. The proposed system is simulated on MATLAB/SIMULINK under various transient conditions, such as steady state, voltage sag, swell, distorted, unbalance, dynamic load, and load shedding conditions. Moreover, the overall system is developed on a laboratory prototype experimental setup. The simulation outcomes are validated through an experimental platform under above said conditions in respect of total harmonic distortion (THD) of grid current and voltages. Results of the system are found well and also maintained within the standard limits of IEEE-519.