Plethysmographic signals were measured remotely (>1m) using ambient light and a simple consumer level digital camera in movie mode. Heart and respiration rates could be quantified up to several harmonics. Although the green channel featuring the strongest plethysmographic signal, corresponding to an absorption peak by (oxy-) hemoglobin, the red and blue channels also contained plethysmographic information. The results show that ambient light photo-plethysmography may be useful for medical purposes such as characterization of vascular skin lesions (e.g., port wine stains) and remote sensing of vital signs (e.g., heart and respiration rates) for triage or sports purposes.
BACKGROUND: Contactless, camera-based photoplethysmography (PPG) interrogates shallower skin layers than conventional contact probes, either transmissive or reflective. This raises questions on the calibratability of camera-based pulse oximetry. METHODS: We made video recordings of the foreheads of 41 healthy adults at 660 and 840 nm, and remote PPG signals were extracted. Subjects were in normoxic, hypoxic, and low temperature conditions. Ratio-of-ratios were compared to reference Spo 2 from 4 contact probes. RESULTS: A calibration curve based on artifact-free data was determined for a population of 26 individuals. For an Spo 2 range of approximately 83% to 100% and discarding short-term errors, a root mean square error of 1.15% was found with an upper 99% one-sided confidence limit of 1.65%. Under normoxic conditions, a decrease in ambient temperature from 23 to 7°C resulted in a calibration error of 0.1% (±1.3%, 99% confidence interval) based on measurements for 3 subjects. PPG signal strengths varied strongly among individuals from about 0.9 × 10−3 to 4.6 × 10−3 for the infrared wavelength. CONCLUSIONS: For healthy adults, the results present strong evidence that camera-based contactless pulse oximetry is fundamentally feasible because long-term (eg, 10 minutes) error stemming from variation among individuals expressed as A*rms is significantly lower (<1.65%) than that required by the International Organization for Standardization standard (<4%) with the notion that short-term errors should be added. A first illustration of such errors has been provided with A**rms = 2.54% for 40 individuals, including 6 with dark skin. Low signal strength and subject motion present critical challenges that will have to be addressed to make camera-based pulse oximetry practically feasible.
Diffuse-reflectance spectroscopy for measurement of the absorption and scattering coefficients of biological tissue produces reliable results for wavelengths from 650 to 1050 nm. Implicitly, this approach assumes homogeneously distributed absorbers. A correction factor is introduced for inhomogeneous distribution of blood concentrated in discrete cylindrical vessels. This factor extends the applicability of diffusion theory to lower wavelengths. We present measurements of in vivo optical properties in the wavelength range 500–1060 nm.
Laser treatment of port wine stains has often been modelled assuming that blood is distributed homogeneously over the dermal volume, instead of enclosed within discrete vessels. The purpose of this paper is to analyse the consequences of this assumption. Due to strong light absorption by blood, fluence rate near the centre of the vessel is much lower than at the periphery. Red blood cells near the centre of the vessel therefore absorb less light than those at the periphery. Effectively, when distributed homogeneously over the dermis, fewer red blood cells would produce the same absorption as the actual number of red blood cells distributed in discrete vessels. We quantified this effect by defining a correction factor for the effective absorbing blood volume of a single vessel. For a dermis with multiple vessels, we used this factor to define an effective homogeneous blood concentration. This was used in Monte Carlo computations of the fluence rate in a homogeneous skin model, and compared with fluence rate distributions using discrete blood vessels with equal dermal blood concentration. For realistic values of skin parameters the homogeneous model with corrected blood concentration accurately represents fluence rates in the model with discrete blood vessels. In conclusion, the correction procedure simplifies the calculation of fluence rate distributions in turbid media with discrete absorbers. This will allow future Monte Carlo computations of, for example, colour perception and optimization of vascular damage by laser treatment of port wine stain models with realistic vessel anatomy.