Assessing tumour necrosis factor-α (TNF-α) levels in the human body has become an essential tool to recognize heart failure (HF). In this work, label-free, rapid, easy to use ImmunoFET based on an ion-sensitive field effect transistor (ISFET) was developed for the detection of TNF-α protein. Monoclonal anti-TNF-α antibodies (anti-TNF-α mAb) were immobilized on an ISFET gate made of silicon nitride (Si3N4) after salinization with 11-(triethoxysilyl) undecanal (TESUD). The obtained ISFET functionalized with the mAbs (ImmunoFET) was used to detect TNF-α protein in both phosphate buffer saline (PBS) and artificial saliva (AS). The change in the threshold voltage of the gate (∆VT) showed approximately linear dependency on the concentration of the antigens in the range 5–20 pg/mL for both matrixes. The cross-selectivity study showed that the developed ImmunoFET demonstrated to be selective towards TNF-α, when compared to other HF biomarkers such as N-terminal pro-brain natriuretic peptide (NT-proBNP), interleukin-10 (IL-10), and cortisol, even if further experiments have to be carried out for decreasing possible unspecific absorption phenomena. To the best of our knowledge, this is the first ImmunoFET that has been developed based on Si3N4 for TNF-α detection in AS by electrical measurement.
A novel impedimetric microsensor based on a double-layered imprinted polymer film has been constructed for the sensitive detection of the herbicide, glyphosate (GLY), in water. It is based on electropolymerized polypyrrole films, doped with cobaltabis(dicarbollide) ions ([3,3′-Co(1,2-C2B9H11)2]), as a solid contact layer between the gold microelectrode surface and the molecularly imprinted chitosan film (CS-MIPs/PPy/Au). Electrochemical Impedance Spectroscopy (EIS) was used for the characterization of the CS-molecular imprinted polymers (MIPs)/PPy/Au in the presence of GLY concentrations between 0.31 pg/mL and 50 ng/mL. Experimental responses of CS-MIPs/PPy/Au are modeled for the first time using an exact mathematical model based on physical theories. From the developed model, it was possible to define the optimal range of the parameters that will impact the quality of impedance spectra and then the analytical performance of the obtained microsensor. The obtained microsensor shows a low detection limit of 1 fg/mL (S/N = 3), a good selectivity, a good reproducibility, and it is regenerable.
8 July 2025 in IEEE Transactions on Microwave Theory and Techniques
In-cabin monitoring systems (iCM) are transforming the automotive industry’s approach to safety and occupant well-being. Among the various sensing technologies, radar has emerged as a highly effective solution due to its robustness in challenging conditions such as poor lighting or obstructed view. This article reviews the state-of-the-art radar technologies used for critical automotive safety applications, including child presence detection (CPD), seat belt reminder (SBR), intrusion detection systems (IDS), occupant out-of-position (OOP) analysis, and vital sign monitoring. With emerging regulatory requirements, such as the European New Car Assessment Program (Euro NCAP) standards mandating CPD and SBR, radar technology provides a scalable, cost-effective solution for automakers. This article examines the underlying radar principles, system architectures, capabilities, and limitations of the three main used radar technologies [Doppler, frequency modulated continuous wave (FMCW), and ultrawideband (UWB)] for iCM, addressing both technical challenges and opportunities for enhancing vehicle safety.