Jeeun Kang

Dr. Jeeun Kang

Department of Radiology, Johns Hopkins University, Baltimore, MD, USA
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2012 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
GKGi-Duck Kim
Gi-Duck Kim
CYChanghan Yoon
Changhan Yoon
SKSang-Bum Kye
Sang-Bum Kye
YLYoungbae Lee
Youngbae Lee
Jeeun KangJeeun Kang
Jeeun Kang
TSTai-kyong Song
Tai-kyong Song
We present a cost-effective portable ultrasound system based on a single field-programmable gate array (FPGA) for point-of-care applications. In the portable ultrasound system developed, all the ultrasound signal and image processing modules, including an effective 32-channel receive beamformer with pseudo-dynamic focusing, are embedded in an FPGA chip. For overall system control, a mobile processor running Linux at 667 MHz is used. The scan-converted ultrasound image data from the FPGA are directly transferred to the system controller via external direct memory access without a video processing unit. The potable ultrasound system developed can provide real-time B-mode imaging with a maximum frame rate of 30, and it has a battery life of approximately 1.5 h. These results indicate that the single FPGA-based portable ultrasound system developed is able to meet the processing requirements in medical ultrasound imaging while providing improved flexibility for adapting to emerging POC applications.

25 January 2012 in Optics Express
Verified
Journal Article
Closed access
PDF file
CYChanghan Yoon
Changhan Yoon
Jeeun KangJeeun Kang
Jeeun Kang
SHSeunghee Han
Seunghee Han
YYYangmo Yoo
Yangmo Yoo
TSTai-kyong Song
Tai-kyong Song
Jin Ho ChangJin Ho Chang
Jin Ho Chang
Real-time photoacoustic (PA) imaging involves beamforming methods using an assumed fixed sound speed, typically 1540 m/s in soft tissue. This leads to degradation of PA image quality because the true sound speed changes as PA signal propagates through different types of soft tissues: the range from 1450 m/s to 1600 m/s. This paper proposes a new method for estimating an optimal sound speed to enhance the cross-sectional PA image quality. The optimal sound speed is determined when coherent factor with the sound speed is maximized. The proposed method was validated through simulation and ex vivo experiments with microcalcification-contained breast cancer specimen. The experimental results demonstrated that the best lateral resolution of PA images of microcalcifications can be achieved when the optimal sound speed is utilized.

29 June 2016 in Nanoscale
Verified
Journal Article
Closed access
PDF file
KJKuk-Youn Ju
Kuk-Youn Ju
Jeeun KangJeeun Kang
Jeeun Kang
JPJung Pyo
Jung Pyo
JLJoohyun Lim
Joohyun Lim
Jin Ho ChangJin Ho Chang
Jin Ho Chang
JLJin-Kyu Lee
Jin-Kyu Lee
We present a new melanin-like nanoparticle (MelNP) and its performance evaluation results. This particle is proposed as an exogenous contrast agent for photoacoustic (PA) imaging. Conventional PA contrast agents are based on non-biological materials. In contrast, the MelNPs are organic nanoparticles inspired by natural melanin. Melanin is an endogenous chromophore that has the ability to produce a PA signal in vivo. The developed MelNPs are capable of aggregating with one another under mildly acidic conditions after introducing hydrolysis-susceptible citraconic amide on the surface of bare MelNPs. We ascertained that the physical aggregation of the MelNPs resulted in an increased PA signal strength in the near-infrared window of biological tissue (i.e., 700 nm) without absorption tuning. This phenomenon is likely because of the overlapping thermal fields of the developed MelNPs. The PA signal produced from the developed MelNPs, after exposure to mildly acidic conditions (i.e., pH 6), is 8.1 times stronger than under neutral conditions. This unique characteristic found in this study can be utilized in a practical strategy for highly sensitive in vivo cancer target imaging in response to its acidic microenvironment. This approach to amplify the PA response of MelNPs in clusters could accelerate the use of MelNPs as an alternative to non-biological nanoprobes, so that MelNPs may be applicable in PA imaging and functional PA imaging such as stimuli sensitive, multimodal, and theranostic imaging.

13 April 2018 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
HZHaichong Zhang
Haichong Zhang
YCYing Chen
Ying Chen
Jeeun KangJeeun Kang
Jeeun Kang
ALAla Lisok
Ala Lisok
IMIl Minn
Il Minn
EBEmad M. Boctor
Emad M. Boctor

22 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Jeeun KangJeeun Kang
Jeeun Kang
Jin Ho ChangJin Ho Chang
Jin Ho Chang
SKSun Mi Kim
Sun Mi Kim
HLHak Jong Lee
Hak Jong Lee
HKHaemin Kim
Haemin Kim
TSTai-kyong Song
Tai-kyong Song
Precise sentinel lymph node (SLN) identification is crucial not only for accurate diagnosis of micro-metastases at an early stage of cancer progression but also for reducing the number of SLN biopsies (SLNB) to minimize their severe side effects. Furthermore, it is desirable that an SLNB guidance should be as safe as possible in routine clinical use. Although there are currently various SLNB guidance methods for pre-operative or intra-operative assessment, none are ideal. We propose a real-time SLNB guidance method using contrast-enhanced tri-modal images (i.e., ultrasound, photoacoustic, and fluorescence) acquired by a recently developed hand-held tri-modal probe. The major advantage of tri-modal imaging is demonstrated here through an in vivo study of the technically-difficult case of nodal obstruction that frequently leads to false-negative results in patients. The results in a tumor model in rabbits and normal controls showed that tri-modal imaging is capable of clearly identifying obstructed SLNs and of indicating their metastatic involvement. Based on these findings, we propose an SLNB protocol to help surgeons take full advantage of the complementary information obtained from tri-modal imaging, including for pre-operative localization, intra-operative biopsy guidance and post-operative analysis.

30 June 2015 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Jeeun KangJeeun Kang
Jeeun Kang
CYChanghan Yoon
Changhan Yoon
JLJaejin Lee
Jaejin Lee
SKSang-Bum Kye
Sang-Bum Kye
YLYongbae Lee
Yongbae Lee
TSTai-kyong Song
Tai-kyong Song
In this paper, we present a novel system-on-chip (SOC) solution for a portable ultrasound imaging system (PUS) for point-of-care applications. The PUS-SOC includes all of the signal processing modules (i.e., the transmit and dynamic receive beamformer modules, mid- and back-end processors, and color Doppler processors) as well as an efficient architecture for hardware-based imaging methods (e.g., dynamic delay calculation, multi-beamforming, and coded excitation and compression). The PUS-SOC was fabricated using a UMC 130-nm NAND process and has 16.8 GFLOPS of computing power with a total equivalent gate count of 12.1 million, which is comparable to a Pentium-4 CPU. The size and power consumption of the PUS-SOC are 27×27 mm 2 and 1.2 W, respectively. Based on the PUS-SOC, a prototype hand-held US imaging system was implemented. Phantom experiments demonstrated that the PUS-SOC can provide appropriate image quality for point-of-care applications with a compact PDA size ( 200×120×45 mm 3 ) and 3 hours of battery life.