Miguel Alonso-Resta

Miguel Alonso-Resta


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2026 in Electronics
Verified
Journal Article
Open access
PDF file
CMCAROLINA NICOLAS MARTIN
CAROLINA NICOLAS MARTIN
DSDavid Santos-Martin
David Santos-Martin
JGJorge González García
Jorge González García
MAMiguel Alonso-Resta
Miguel Alonso-Resta
Efficiency-oriented control of induction motor drives reduces rotor flux at partial load, but the resulting reduction in speed-loop gain degrades closed-loop bandwidth under fixed-gain control. The maximum torque per ampere (MTPA) constraint allows an exact resolution of this trade-off. Enforcing MTPA as a structural control law reduces the conventional two-input field-oriented-control plant to a single-input single-output system. Its linearized transfer function is a second-order plant with a real zero at twice the rotor-flux pole frequency. A gain-scheduled proportional–integral controller, whose gain is inversely proportional to the MTPA operating-point current, cancels the operating-point dependence and maintains constant crossover frequency and phase margin without an additional flux observer or look-up table. Four strategies are compared in simulation and experimentally on an 18.5 kW induction machine under airborne-wind-energy pumping cycles: standard field-oriented control, fixed-gain MIMO-MTPA, the proposed SISO-MTPA, and loss minimization. SISO-MTPA is the only strategy that improves both net harvested energy and speed tracking relative to the FOC baseline while remaining undominated: its energy is within 10% of the MTPA-optimal strategies, its speed-error RMSE is approximately 1.7 times lower, and its maximum deviation is over 40% lower. Against an industrial drive under high-power generation, it reduces speed-tracking RMSE by 47% with comparable generated energy.

18 November 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MAMiguel Alonso-Resta
Miguel Alonso-Resta
CMCAROLINA NICOLAS MARTIN
CAROLINA NICOLAS MARTIN
JGJorge González García
Jorge González García
DSDavid Santos-Martin
David Santos-Martin
In electric-vehicle induction-motor drives, maximum-torque-per-ampere (MTPA) control improves partial-load efficiency by reducing rotor flux, but the resulting remagnetisation delay can impair torque delivery at traction onset. Fixed minimum magnetising-current limits improve response but impose losses throughout the drive cycle. This paper schedules the limit with a closed-form rule derived from rotor-flux dynamics and a binary warning from brake-pedal release at low speed, without predicting future torque or modifying the MTPA controller. In two simulated urban cycles, the rule alone, reacting to the present demand, eliminates the onsets degraded under the nominal limit at no energy cost, and the warning cuts the remaining peak torque error about threefold for under 1.5 Wh. On the New York City Cycle, relative to the lowest-energy fixed limit without degraded onsets, the supervisor with warning reduces peak torque error from 19.36 to 5.16 N·m and energy from 132.57 to 129.34 Wh. Warning leads of about one rotor time constant, as provided by brake release, also make peak torque error far less sensitive to rotor-resistance variation. Experiments on an 18.5 kW drive confirm real-time anticipative magnetisation: mean estimated onset flux reaches 0.81 Wb, with stator copper loss only 1.27 Wh above the nominal limit.