Understanding electrochemical reactions at the surface of electrodes requires the accurate calculation of key parameters—the transfer coefficient (α), diffusion coefficient (D0), and heterogeneous electron transfer rate constant (k0). The choice of method to calculate these parameters requires careful consideration based on the nature of the electrochemical reaction. In this study, we conducted the cyclic voltammetry of paracetamol to calculate the values of these parameters using different methods and present a comparative analysis. Our results demonstrate that the Ep − Ep/2 equation for α and the modified Randles–Ševčík equation for D0 is particularly effective for the calculations of these two parameters. The Kochi and Gileadi methods are reliable alternatives for the calculation of k0. Nicholson and Shain’s method using the equation k0 = Ψ(πnD0Fν/RT)1/2 gives the overestimated values of k0. However, the value of k0 calculated using the plot of ν−1/2 versus Ψ (from the Nicholson and Shain equation, where ν is scan rate) agrees well with the values calculated from the Kochi and Gilaedi methods. This study not only identifies optimal methodologies for quasi-reversible reactions but also contributes to a deeper understanding of electrochemical reactions involving complex electron transfer and coupled chemical reactions, which can be broadly applicable in various electrochemical studies.
Every year, tuberculosis affects the lungs of millions of people and rifampicin is the commonly used medicine for its treatment due to its antibiotic nature. The frequent use of rifampicin may lead to its increased concentration in the water resources. This research work is focused on the cloud point extraction (CPE) procedure for the preconcentration of rifampicin prior to its determination in water. The UV/vis spectrophotometric method was adapted for the measurement of rifampicin content after the phase separation. Triton-X 100 was used as the nonionic surfactant which contains hydrophilic polyethylene chain feasible for the extraction of analyte. Various analytical parameters that can affect the extraction efficacy were optimized to achieve linearity of the proposed method in the concentration range of 3.54–81.41 mgL–1. The Limit of detection and quantification were 1.261 and 4.212 mgL–1, respectively. The Preconcentration factor was 40 with relative standard deviation (%RSD) of 2.504%. The standard addition methodology was adopted for the validation of this procedure and effectively applied for the determination of rifampicin in real wastewater samples.
Background: The magnetic nanocomposites are very important as a reusable sorbents for the extraction of Cd(II) and other toxic metals from water samples. Methods: The Ag/MgO@Fe3O4 nanocomposite was synthesized by the coprecipitation method and characterized by the XRD, EDX, SEM, UV-vis spectroscopy and FTIR. This nanocomposite was used to extract Cd(II) from water samples prior to its quantitative analysis with FAAS. Different variables, i.e. pH, temperature, amount of nanosorbent, adsorption/desorption and dilution were optimized. Results: The method was successfully applied to determine Cd(II) in real water samples with excellent recoveries (98%). The present method has lower detection (0.29) and quantification limit (0.97 ng mL-1). Conclusions: The Ag/MgO@Fe3O4 nanocomposite based magnetic extraction is a simple, fast, reproducible, less expansive and efficient technique for the Cd(II) extraction in water samples. The developed sorbent can be recycled and reused (20 times).