This study presents the design and analysis of a unique reconfigurable multiband antenna that utilizes reciprocity theory and fractal geometry, with the PIN diode serving as the driving mechanism for compact, advanced wireless communication systems. The proposed antenna design system comprises architectural structures known as Ohmic (Antenna 1) and Sigma (Antenna 2). The simulation of the suggested method was conducted using the HFSS software in Ansys. The analysis and presentation of the simulated and measured findings are conducted. The presented antenna system is designed to radiate at a center frequency of 4 GHz–5 GHz. The findings suggest that the antenna system suggested in this study provides the capability for multi-frequency operation, which is regulated by the ON and OFF states of the PIN diode. Ohmic antenna radiates from 2.3 GHz to 6.8 GHz, achieving 4 frequency bands of operation during the ON state of the diode and covers from 2.5 GHz to 6.85 GHz in the OFF state, enabling three frequency bands of operation. Reciprocally, the Sigma antenna radiates from 2.3 GHz to 6.4 GHz, covering 3 frequency bands of operation during the ON state and achieves 4 frequency bands of operation covering from 2.6 GHz to 6.2 GHz during the OFF state. Furthermore, the separate functionality of the scheme’s antennas is also showcased. The empirical examination of the antenna constructed using a FR4 substrate provided empirical support for the concurrence observed in the simulation outcomes.
20 August 2022 in Indian Journal of Computer Science and Engineering
Cardiovascular diseases (CVDs) are among the primary causes of mortality and there is a considerable need for easy and non-invasive modality for early risk assessment. Endothelial dysfunction is an early marker for cardiovascular abnormalities and assessing it an early stage can save crucial lives. Hence in this work, a novel non-invasive evaluation method, along with wearable arm-band prototype device to evaluate peripheral endothelial function, have been developed for the early detection of cardiovascular health problems. The proposed wearable system integrates a Qt-Py ESP32 microcontroller, MCP3422 analog front-end (AFE), NTC thermistor, and a rechargeable Li-ion battery within a compact arm-band platform. . The proposed evaluation method is based on thermal sensing wherein skin temperature variations are recorded during a hand exercise routine and the resulting skin temperature variations are correlated to peripheral blood flow variations. High-resolution AFE is used for digitization of collected sensor signals and ESP32 is used for feature extraction and analysis. A non-invasive assessment algorithm is applied to determine the quantity of endothelial function and deviations therein that could signal cardiovascular impairment. The proposed prototype is able to capture physiological change related to peripheral vascular function with good reliability demonstrated by experimental validation conducted on 100 individuals. Thus, the results obtained showed good prospects for applying these devices to early diagnosis of cardiovascular diseases, tele monitoring patients and preventive care. The wearable arm-band device, which is proposed to be a low cost, portable and easy-to-use solution, presents a potential opportunity for continuous assessment of cardiovascular health.