Lissajous microscanners are very attractive in compact laser scanning applications such as endomicroscopy or pro-projection display owing to high mechanical stability and low operating voltages. The scanning frequency serves as a critical factor for determining the scanning imaging quality. Here we report the selection rule of scanning frequencies that can realize high definition and high frame-rate (HDHF) full-repeated Lissajous scanning imaging. The fill factor (FF) monotonically increases with the total lobe number of a Lissajous curve, i.e., the sum of scanning frequencies divided by the great common divisor (GCD) of bi-axial scanning frequencies. The frames per second (FPS), called the pattern repeated rate or the frame rate, linearly increases with GCD. HDHF Lissajous scanning is achieved at the bi-axial scanning frequencies, where the GCD has the maximum value among various sets of the scanning frequencies satisfying the total lobe number for a target FF. Based on this selection rule, the experimental results clearly demonstrate that conventional Lissajous scanners substantially increase both FF and FPS by slightly modulating the scanning frequencies at near the resonance within the resonance bandwidth of a Lissajous scanner. This selection rule provides a new guideline for HDHF Lissajous scanning in compact laser scanning systems.
We report a fully packaged and compact forward viewing endomicroscope by using a resonant fiber scanner with two dimensional Lissajous trajectories. The fiber scanner comprises a single mode fiber with additional microstructures mounted inside a piezoelectric tube with quartered electrodes. The mechanical cross-coupling between the transverse axes of a resonant fiber with a circular cross-section was completely eliminated by asymmetrically modulating the stiffness of the fiber cantilever with silicon microstructures and an off-set fiber fragment. The Lissajous fiber scanner was fully packaged as endomicroscopic catheter passing through the accessory channel of a clinical endoscope and combined with spectral domain optical coherence tomography (SD-OCT). Ex-vivo 3D OCT images were successfully reconstructed along Lissajous trajectory. The preview imaging capability of the Lissajous scanning enables rapid 3D imaging with high temporal resolution. This endoscopic catheter provides many opportunities for on-demand and non-invasive optical biopsy inside a gastrointestinal endoscope.
MEMS laser scanning enables the miniaturization of endoscopic catheters for advanced endomicroscopy such as confocal microscopy, multiphoton microscopy, optical coherence tomography, and many other laser scanning microscopy. These advanced biomedical imaging modalities open a great potential for in vivo optical biopsy without surgical excision. They have huge capabilities for detecting on-demand early stage cancer with non-invasiveness. In this article, the scanning arrangement, trajectory, and actuation mechanism of endoscopic microscanners and their endomicroscopic applications will be overviewed.
An endomicroscope opens new frontiers of non-invasive biopsy for in vivo imaging applications. Here we report two-photon laser scanning endomicroscope for in vivo cellular and tissue imaging using a Lissajous fiber scanner. The fiber scanner consists of a piezoelectric (PZT) tube, a single double-clad fiber (DCF) with high fluorescence collection, and a micro-tethered-silicon-oscillator (MTSO) for the separation of biaxial resonant scanning frequencies. The endomicroscopic imaging exhibits 5 frames/s with 99% in scanning density by using the selection rule of scanning frequencies. The endomicroscopic scanner was compactly packaged within a stainless tube of 2.6 mm in diameter with a high NA gradient-index (GRIN) lens, which can be easily inserted into the working channel of a conventional laparoscope. The lateral and axial resolutions of the endomicroscope are 0.70 µm and 7.6 μm, respectively. Two-photon fluorescence images of a stained kidney section and miscellaneous ex vivo and in vivo organs from wild type and green fluorescent protein transgenic (GFP-TG) mice were successfully obtained by using the endomicroscope. The endomicroscope also obtained label free images including autofluorescence and second-harmonic generation of an ear tissue of Thy1-GCaMP6 (GP5.17) mouse. The Lissajous scanning two-photon endomicroscope can provide a compact handheld platform for in vivo tissue imaging or optical biopsy applications.
Scanning MEMS (micro-electro-mechanical system) mirrors are attractive given their potential use in a diverse array of laser scanning display and imaging applications. Here we report on an electrostatic MEMS mirror for high definition and high frame rate (HDHF) Lissajous scanning. The MEMS mirror comprised a low Q-factor inner mirror and frame mirror, which provided two-dimensional scanning at two similar resonant scanning frequencies with high mechanical stability. The low Q inner mirror enabled a broad frequency selection range. The high definition and high frame rate (HDHF) Lissajous scanning of the MEMS mirror was achieved by selecting a set of scanning frequencies near its resonance with a high greatest common divisor (GCD) and a high total lobe number. The MEMS mirror had resonant scanning frequencies at 5402 Hz and 6702 Hz in x and y directions, respectively. The selected pseudo-resonant frequencies of 5450 Hz and 6700 Hz for HDHF scanning provided 50 frames per second with 94% fill factor in 256 × 256 pixels. This Lissajous MEMS mirror could be utilized for assorted HDHF laser scanning imaging and display applications.
We report a novel MEMS fiber scanner with an electrothermal silicon microactuator and a directly mounted optical fiber. The microactuator comprises double hot arm and cold arm structures with a linking bridge and an optical fiber is aligned along a silicon fiber groove. The unique feature induces separation of resonant scanning frequencies of a single optical fiber in lateral and vertical directions, which realizes Lissajous scanning during the resonant motion. The footprint dimension of microactuator is 1.28 x 7 x 0.44 mm3. The resonant scanning frequencies of a 20 mm long optical fiber are 239.4 Hz and 218.4 Hz in lateral and vertical directions, respectively. The full scanned area indicates 451 μm x 558 μm under a 16 Vpp pulse train. This novel laser scanner can provide many opportunities for laser scanning endomicroscopic applications.