For the head-and-neck cancer bilateral irradiation, intensity-modulated radiation therapy (IMRT) is the most reported technique as it enables both target dose coverage and organ-at-risk (OAR) sparing. However, during the last 20 years, three-dimensional conformal radiotherapy (3DCRT) techniques have been introduced, which are tailored to improve the classic shrinking field technique, as regards both planning target volume (PTV) dose conformality and sparing of OAR’s, such as parotid glands and spinal cord. In this study, we tested experimentally in a sample of 13 patients, four of these advanced 3DCRT techniques, all using photon beams only and a unique isocentre, namely Bellinzona, Forward-Planned Multisegments (FPMS), ConPas, and field-in-field (FIF) techniques. Statistical analysis of the main dosimetric parameters of PTV and OAR’s DVH’s as well as of homogeneity and conformity indexes was carried out in order to compare the performance of each technique. The results show that the PTV dose coverage is adequate for all the techniques, with the FPMS techniques providing the highest value for D95%; on the other hand, the best sparing of parotid glands is achieved using the FIF and ConPas techniques, with a mean dose of 26 Gy to parotid glands for a PTV prescription dose of 54 Gy. After taking into account both PTV coverage and parotid sparing, the best global performance was achieved by the FIF technique with results comparable to that of IMRT plans. This technique can be proposed as a valid alternative when IMRT equipment is not available or patient is not suitable for IMRT treatment.
The present article seeks to determine the annual effective doses of 222Rn exposure, effective radium content and radon exhalation rates in some building materials from the local market of Ibb province, Yemen. A total of 33 samples of building materials were collected from the target area. The radon exhalation rate and effective radium content in these samples were measured using solid-state nuclear track detector, which has become an important tool in every investigation of the radon levels in the surrounding environment. Surface exhalation rate has been found to vary from 178.90 to 1267.6 mBq m−2 h−1, whereas mass exhalation rate has been found to vary from 5.51 to 33.25 mBq kg−1 h−1. All the values of effective radium content in all samples under test were found to be quite lower than the permissible value of 370 Bq kg−1 recommended by Organization for Economic Cooperation and Development. Annual effective doses have also been estimated.
1 June 2020 in Journal of Medical Imaging and Radiation Sciences
Purpose: The aim of this study was to evaluate planning target volume (PTV) margins for two different locations using an electronic portal imaging device (EPID) to ensure that the correct radiation dose is delivered to the tumour when using intensity-modulated radiation therapy (IMRT). Materials and methods: Setup data were collected from 40 patients treated with IMRT for head and neck cancer (HN) (20 patients) and prostate cancer (20 patients). Setup errors from 720 registration images were analysed to evaluate systematic and random errors. Thereafter, optimal PTV margins were calculated based on International Commission on Radiation Units and Measurements 62 (ICRU), Stroom and Parker formulas compared with the Van Herk’s recipe. Results: To calculate the margins around the PTV, several different formulas have been used. Setup margins ranged between 2–4·3, 2·2–4·6 and 2·1–4·7 mm in X, Y and Z directions, respectively, for HN cases. Similarly, for the prostate site, setup margins ranged between 3·7–8·3, 3·2–6·8 and 3·3–8·2 mm in X, Y and Z directions. Conclusion: To ensure better coverage of target volume, we adopted a PTV margin of 5 mm for HN PTVs and 10 mm for prostate PTVs in our department.
18 October 2024 in British and Irish Orthoptic Journal
Ensuring a high level of adherence to wearing spectacles is essential to preserve eye health and achieve optimal vision correction. Comprehending the factors influencing adherence to wearing spectacles can inform strategies to improve eye care outcomes. This study aimed to assess the prevalence and factors influencing adherence to wearing spectacles among Moroccan adults residing the Beni-Mellal Khenifra region. A cross-sectional interview survey was conducted involving 389 adult spectacle wearers. Participants were recruited through a multilevel random sampling technique and interviewed using a structured questionnaire. This questionnaire collected data on demographics, spectacle prescription, usage patterns, and barriers to compliance. Compliance was assessed based on self-reported frequency and duration of spectacle wear according to the prescription. Possible factors influencing the wearing of spectacles were investigated using both univariate and multivariate regression models. This study revealed that 57.6% of participants adhered to the recommended use of spectacles. Factors associated with compliance were higher education level, longer duration of spectacle use, awareness about the importance of spectacle wear, absence of a family history, specific refractive error types, and increased severity of refractive errors. Participants reported various reasons for not adhering to the recommended use of spectacles, with the most common being forgetfulness, perceiving improved vision without spectacle, discomfort while wearing spectacle, difficulty adapting to spectacle, and loss of spectacle. Given the high prevalence of non-compliance to spectacle wear among adults in the Beni-Mellal Khenifra region, it is evident that additional efforts are required to improve understanding and education regarding the advantages of consistent spectacle usage. Targeted educational and awareness initiatives have the potential to substantially enhance adherence rates and consequently improve visual health outcomes in the region.