Scaling up continuous reactors with immobilised enzymes requires identifying the hydrodynamic variable that governs biocatalyst stability, because the design criterion for the larger unit depends on it. In this work, a packed-bed reactor with Aspergillus niger inulinase immobilised on citric acid activated Luffa cylindrica was scaled up from a working capacity of 125 mL to 415 mL, with a linear scale factor of 2.21 applied to all design dimensions. The scaled-up reactor was operated at pH 4.6 and 49 °C with flow rates of 3, 5, 7 and 11 mL min-1, equivalent to superficial velocities of 0.42 to 1.55 cm min-1 and space times of 138 to 38 min. Reducing sugars in the effluent were quantified by the 3,5-dinitrosalicylic acid method with a validated calibration (R2 = 0.991; LOQ = 164 mg L-1), and the time course of concentration was described with a first-order decay model whose confidence intervals were obtained by Monte Carlo simulation. With a feed of 1.079 g L-1 inulin, the initial apparent degree of hydrolysis was 20 to 25 % and varied little with space time (elasticity of 0.13), whereas the outlet mass rate scaled with flow rate raised to 0.87 and reached 161 mg h-1 at 11 mL min-1. The apparent decay constant revealed two regimes. At 3 and 5 mL min-1 it was 0.0065 min-1 with no difference between the two flow rates (p = 0.95), giving an operational half-life of 106 min, and at 7 and 11 mL min-1 it increased to 0.036 and 0.062 min-1 (p < 10-5). The change occurred between 0.70 and 0.99 cm min-1 of superficial velocity, was not explained by the processed volume (F = 58.0; p < 10-8) and would only vanish with a between-run variability of kd above 66 %, against an agreement of 0.9 % between the two independent runs of the stable regime. Within the common window of 5 to 30 min, the flow rate of 5 mL min-1 combined a space-time yield of 183 mg L-1 h-1 with a mean concentration of 253 mg L-1 and a substrate utilisation of 21 %, twice that at 11 mL min-1. These results establish superficial velocity as the scale-up criterion for beds of lignocellulosic support and define a stable operating window for the design of larger units.