Liston Matindife

Liston Matindife


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2021 in Complex & Intelligent Systems
Verified
Journal Article
Open access
PDF file
LMListon Matindife
Liston Matindife
YSYanxia Sun
Yanxia Sun
ZWZenghui Wang
Zenghui Wang
The mains signal is a complex fusion of various electrical equipment load signals in a building. In the non-intrusive load monitoring recognition, our main aim is to be able to extract as much load features as possible from the complex aggregate mains signal in a simpler way through a computer vision-based approach as opposed to the powers series signal approach. Power series methods, which are one dimensional in nature, suffer from poor aggregate and load signal feature localization necessitating a larger training dataset spanning very long time periods and normally require signal formatting and pre-processing. We use Gramian angular summation fields to transform the power series into a reduced image dataset that contains a rich set of localized signal features. A computer vision approach allows us to capture as much information as possible, and then propose an image-based mains load recognition system with high performance. In this paper for the entire recognition system, we use convolutional neural networks that very well adapted to vision recognition. The load signal image disaggregation is achieved through the powerful stacked denoising autoencoder noise extraction network. To test the proposed system, some simulations and comparisons are carried out and the results show that our easier to handle method can achieve acceptable performance.

28 February 2018 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
LMListon Matindife
Liston Matindife
ZWZenghui Wang
Zenghui Wang
YSYanxia Sun
Yanxia Sun
This study develops a new integrated measurement and control system for intermixed biogas and photovoltaic systems to achieve safe and optimal energy usage. Literature and field studies show that existing control methods on small- to medium-scale systems fall short of comprehensive system optimization and fault diagnosis, hence the need to revisit these control methods. The control strategy developed in this study is intelligent as it is wholly based on fuzzy logic algorithms. Fuzzy logic controllers due to their superior nonlinear problem solving capabilities to classical controllers considerably simplify controller design. The mathematical models that define classical controllers are difficult or impossible to realize in biogas and photovoltaic generation process. A microcontroller centered fuzzy logic measurement and control embedded system is designed and developed on the existing hybrid biogas and photovoltaic installations. The designed system is able to accurately predict digester stability, quantify biogas output, and carry out biogas fault detection and control. Optimized battery charging and photovoltaic fault detection and control are also successfully implemented. The system is able to optimize the operation and performance of biogas and photovoltaic energy generation.

1 July 2017
Verified
Conference Paper
Closed access
LMListon Matindife
Liston Matindife
ZWZenghui Wang
Zenghui Wang
Photovoltaic systems, whether they are domestic, commercial or industrial often incorporate some forms of system protection. However, elaborate real-time fault detection is not defined for most such systems. To address this shortfall, a comprehensive photovoltaic installation system fault detection and control strategy is presented in this paper. The designed system is made up of fault detection in any of one of the photovoltaic system components that include the solar panel, charge controller, battery and inverter. The system also includes battery and user load current control. Fuzzy logic principle, due to its powerful non-linear problem solving capabilities is used in formulation of the fault detection and control algorithms as opposed to the classical method. This results in simpler, cheaper and faster hardware, which in this case is implemented on the PIC18F4550 microcontroller.

1 November 2016
Verified
Conference Paper
Closed access
LMListon Matindife
Liston Matindife
ZWZenghui Wang
Zenghui Wang
Critical aspects that are lacking in present digester operation are that of fault detection and control. Too high or too low a biogas pressure, methane gas leak, oxygen ingress into the digester and varying slurry levels are all potential contributors of catastrophe, to the installation and to the user. In this paper an integrated fault detection and control strategy based both on fuzzy logic algorithm of internal digesters' operating conditions and external leak detection is developed. The fuzzy logic algorithm being fed by pressure and slurry level inputs seeks to establish the internal danger level of the digester at any particular instant with the view of taking corrective action, whilst any methane and oxygen leaks are to be immediately halted. The fault detection and control strategy is implemented in the PIC18F4550-I/P microcontroller.

23 August 2022 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
PDF file
LMListon Matindife
Liston Matindife
YSYanxia Sun
Yanxia Sun
ZWZenghui Wang
Zenghui Wang
In this article, we present the recognition of nonintrusive disaggregated appliance signals through a reduced dataset computer vision deep learning approach. Deep learning data requirements are costly in terms of acquisition time, storage memory requirements, computation time, and dynamic memory usage. We develop our recognition strategy on Siamese and prototypical reduced data few-shot classification algorithms. Siamese networks address the 1-shot recognition well. Appliance activation periods vary considerably, and this can result in imbalance in the number of appliance-specific generated signal images. Prototypical networks address the problem of data imbalance in training. By first carrying out a similarity test on the entire dataset, we establish the quality of our data before input into the deep learning algorithms. The results give acceptable performance and show the promise of few-shot learning in recognizing appliances in the nonintrusive load-monitoring scheme for very limited data samples.

13 August 2020
Verified
Book Chapter
Closed access
PDF file
LMListon Matindife
Liston Matindife
YSYanxia Sun
Yanxia Sun
ZWZenghui Wang
Zenghui Wang