Klaus Drese

Prof. Klaus Drese

Coburg University of Applied Sciences, Coburg, Bavaria, Germany
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2004 in AIChE Journal
Verified
Journal Article
Closed access
PDF file
FJF. Jiang
F. Jiang
Klaus DreseKlaus Drese
Klaus Drese
SHS. Hardt
S. Hardt
MKM. Küpper
M. Küpper
FSF. Schönfeld
F. Schönfeld

8 April 2005 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
SHS. Hardt
S. Hardt
Klaus DreseKlaus Drese
Klaus Drese
VHV. Hessel
V. Hessel
FSF. Schönfeld
F. Schönfeld

1 January 1999 in The European Physical Journal D
Verified
Journal Article
Closed access
PDF file
Klaus DreseKlaus Drese
Klaus Drese
MHM. Holthaus
M. Holthaus

29 January 2010 in Analytical Chemistry
Verified
Journal Article
Closed access
NLNoemi Laboria
Noemi Laboria
Alex FragosoAlex Fragoso
Alex Fragoso
WKWolfgang Kemmner
Wolfgang Kemmner
DLDaniel Latta
Daniel Latta
ONOlle Nilsson
Olle Nilsson
CSCiara O Kathleen Sullivan
Ciara O Kathleen Sullivan

28 January 2005 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
AGAnja Gulliksen
Anja Gulliksen
LSLars Anders Solli
Lars Anders Solli
Klaus DreseKlaus Drese
Klaus Drese
OSOlaf Sörensen
Olaf Sörensen
FKFrank Karlsen
Frank Karlsen
RSReidun Sirevåg
Reidun Sirevåg
A general multipurpose microchip technology platform for point-of-care diagnostics has been developed. Real-time nucleic acid sequence-based amplification (NASBA) for detection of artificial human papilloma virus (HPV) 16 sequences and SiHa cell line samples was successfully performed in cyclic olefin copolymer (COC) microchips, incorporating supply channels and parallel reaction channels. Samples were distributed into 10 parallel reaction channels, and signals were simultaneously detected in 80 nl volumes. With a custom-made optical detection unit, the system reached a sensitivity limit of 10−6 µM for artificial HPV 16 sequences, and 20 cells µl−1 for the SiHa cell line. This is comparable to the detection limit of conventional readers, and clinical testing of biological samples in polymer microchips using NASBA is therefore possible.

1 December 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Alex FragosoAlex Fragoso
Alex Fragoso
DLDaniel Latta
Daniel Latta
NLNoemi Laboria
Noemi Laboria
FGFrithjof von Germar
Frithjof von Germar
THThomas E. Hansen-Hagge
Thomas E. Hansen-Hagge
CSCiara O Kathleen Sullivan
Ciara O Kathleen Sullivan
A microsystem integrating electrochemical detection for the simultaneous detection of protein markers of breast cancer is reported. The microfluidic platform was realized by high precision milling of polycarbonate sheets and features two well distinguishable sections: a detection zone incorporating the electrode arrays and the fluid storage part. The detection area is divided into separate microfluidic chambers addressing selected electrodes for the measurement of samples and calibrators. The fluidic storage part of the platform consists of five reservoirs to store the reagents and sample, which are interfaced by septa. These reservoirs have the appropriate volume to run a single assay per cartridge and are manually filled. The liquids from the reservoirs are actuated by applying a positive air pressure (i.e.via a programmable syringe pump) through the septa and are driven to the detection zone via two turning valves. The application of the realised platform in the individual and simultaneous electrochemical detection of proteic cancer markers with very low detection limits are demonstrated. The microsystem has also been validated using real patient serum samples and excellent correlation with ELISA results obtained.