LASSAAD BARHOUMI

LASSAAD BARHOUMI


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LBLASSAAD BARHOUMI
LASSAAD BARHOUMI
FBFrancesca Bellagambi
Francesca Bellagambi
FVFederico Maria Vivaldi
Federico Maria Vivaldi
ABABDOULLATIF BARAKET
ABDOULLATIF BARAKET
YCYohann Clément
Yohann Clément
AEAbdelhamid Errachid
Abdelhamid Errachid
Tumor necrosis factor-α (TNF-α) is a biomarker of inflammation that occurs in patients suffering from heart failure (HF). Saliva can be sampled in a non-invasive way, and it is currently gaining importance as matrix alternative to blood in diagnostic and therapy monitoring. This work presents the development of an immunosensor array based on eight screen-printed gold electrodes to detect TNF-α in saliva samples. Two different functionalization strategies of electrodes were compared. In the first, anti-TNF-α antibodies were chemically bonded onto the electrode by functionalization with 4-carboxymethylaniline. The other functionalization procedure involved the binding of antibodies onto polymer-coated magnetic microparticles, which were then deposited onto the electrode by pulsed chronoamperometry. Finally, the chronoamperometry technique was applied to characterize the modified SPEAu. The use of a secondary antibody anti-TNF-α (Ab-TNF-α-HRP) labelled with horseradish peroxidase (HRP, 2 µg·mL−1) was investigated using tetramethylbenzidine (TMB, pH = 3.75) as electrochemical substrate containing 0.2 mM of H2O2. A sandwich-type detection strategy with a secondary antibody anti-TNF-α provided chronoamperometric analyses in 10 s for each sample. Linearity, precision, limit of detection, and selectivity of devices were investigated. Interferences were evaluated by analyzing solutions containing other cytokine produced during the acute stage of inflammation. The immunosensor showed good performance within the clinically relevant concentration range, with a precision of 8%, and a limit of detection of 0.3 pg/mL. Therefore, it may represent a promising tool for monitoring HF in a non-invasive way.

1 February 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
LBLASSAAD BARHOUMI
LASSAAD BARHOUMI
OKOlfa Karker
Olfa Karker
Salem NasraouiSalem Nasraoui
Salem Nasraoui
BMBen Ali Mounir
Ben Ali Mounir
Olfa KanounOlfa Kanoun
Olfa Kanoun
The dopamine and uric acid are primary products of purine metabolism and they coexist in serum and the extracellular fluid of the central nervous system. Some diseases of the human body are due to abnormal levels of uric acid and dopamine. Thus, the clinical diagnosis of some diseases needs a sensitive and simultaneous analysis of uric acid and dopamine. In this study, a novel conductive composite film containing multi-walled carbon nanotubes (MWTs) with cooper phthalocyanine attached to acrylate polymer (MWCNTs-CuMAPC-PnBA) was fabricated and dropped on a glassy carbon electrode and used for the simultaneous determination of Uric Acid (UA) and dopamine (DA). The modified glassy carbon electrode showed satisfactory electrocatalytic activity toward dopamine and uric acid. Low detection limits were achieved at 0.174 µM of DA and 6.87 µM of UA and the linear detection ranges of DA and UA are 5-200 µM and 20-250 µM respectively. The proposed sensing system based on the modified GCE offers promising results for rapid, cost-effective and selective simultaneous detection of uric acid and dopamine. Also, the complex modified electrode showed satisfactory results to detecting simultaneously UA and DA in real human samples (human Urine) via the standard addition method.