Bo Tian

Dr. Bo Tian

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
BTBo Tian
Bo Tian
FGFei Gao
Fei Gao
JFJeppe Fock
Jeppe Fock
MDMartin Dufva
Martin Dufva
MHMikkel Fougt Hansen
Mikkel Fougt Hansen

1 May 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
DWDian-Bing Wang
Dian-Bing Wang
BTBo Tian
Bo Tian
ZZZhi-Ping Zhang
Zhi-Ping Zhang
XWXu-Ying Wang
Xu-Ying Wang
JFJoy Fleming
Joy Fleming
XZXian-En Zhang
Xian-En Zhang
Detection of Bacillus anthracis in the field, whether as a natural infection or as a biothreat remains challenging. Here we have developed a new lateral-flow immunochromatographic assay (LFIA) for B. anthracis spore detection based on the fact that conjugates of B. anthracis spores and super-paramagnetic particles labeled with antibodies will block the pores of chromatographic strips and form retention lines on the strips, instead of the conventionally reported test lines and control lines in classic LFIA. As a result, this new LFIA can simultaneously realize optical, magnetic and naked-eye detection by analyzing signals from the retention lines. As few as 500-700 pure B. anthracis spores can be recognized with CV values less than 8.31% within 5 min of chromatography and a total time of 20 min. For powdery sample tests, this LFIA can endure interference from 25% (w/v) milk, 10% (w/v) baking soda and 10% (w/v) starch without any sample pre-treatment, and has a corresponding detection limit of 6×10(4) spores/g milk powder, 2×10(5) spores/g starch and 5×10(5) spores/g baking soda. Compared with existing methods, this new approach is very competitive in terms of sensitivity, specificity, cost and ease of operation. This proof-of-concept study can also be extended for detection of many other large-sized analytes.

1 April 2013 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DWDian-Bing Wang
Dian-Bing Wang
BTBo Tian
Bo Tian
ZZZhi-Ping Zhang
Zhi-Ping Zhang
JDJiao-Yu Deng
Jiao-Yu Deng
ZCZong-Qiang Cui
Zong-Qiang Cui
XZXian-En Zhang
Xian-En Zhang

20 January 2020 in Nucleic Acids Research
Verified
Journal Article
Open access
PDF file
BTBo Tian
Bo Tian
GMGabriel Antonio S Minero
Gabriel Antonio S Minero
JFJeppe Fock
Jeppe Fock
MDMartin Dufva
Martin Dufva
MHMikkel Fougt Hansen
Mikkel Fougt Hansen
False-positive results cause a major problem in nucleic acid amplification, and require external blank/negative controls for every test. However, external controls usually have a simpler and lower background compared to the test sample, resulting in underestimation of false-positive risks. Internal negative controls, performed simultaneously with amplification to monitor the background level in real-time, are therefore appealing in both research and clinic. Herein, we describe a nonspecific product-activated single-stranded DNA-cutting approach based on CRISPR (clustered regularly interspaced short palindromic repeats) Cas12a (Cpf1) nuclease. The proposed approach, termed Cas12a-based internal referential indicator (CIRI), can indicate the onset of nonspecific amplification in an exponential rolling circle amplification strategy here combined with an optomagnetic readout. The capability of CIRI as an internal negative control can potentially be extended to other amplification strategies and sensors, improving the performance of nucleic acid amplification-based methodologies.

1 December 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
BTBo Tian
Bo Tian
ZQZhen Qiu
Zhen Qiu
JMJing Ma
Jing Ma
TTTeresa Zardán Gómez de la Torre
Teresa Zardán Gómez de la Torre
Christer JohanssonChrister Johansson
Christer Johansson
MSMattias Strömberg
Mattias Strömberg
Because of the serological cross-reactivity among the flaviviruses, molecular detection methods, such as reverse-transcription polymerase chain reaction (RT-PCR), play an important role in the recent Zika outbreak. However, due to the limited sensitivity, the detection window of RT-PCR for Zika viremia is only about one week after symptom onset. By combining loop-mediated isothermal amplification (LAMP) and AC susceptometry, we demonstrate a rapid and homogeneous detection system for the Zika virus oligonucleotide. Streptavidin-magnetic nanoparticles (streptavidin-MNPs) are premixed with LAMP reagents including the analyte and biotinylated primers, and their hydrodynamic volumes are dramatically increased after a successful LAMP reaction. Analyzed by a portable AC susceptometer, the changes of the hydrodynamic volume are probed as Brownian relaxation frequency shifts, which can be used to quantify the Zika virus oligonucleotide. The proposed detection system can recognize 1 aM synthetic Zika virus oligonucleotide in 20% serum with a total assay time of 27min, which can hopefully widen the detection window for Zika viremia and is therefore promising in worldwide Zika fever control.

13 February 2017 in ACS Nano
Verified
Journal Article
Open access
BTBo Tian
Bo Tian
JMJing Ma
Jing Ma
ZQZhen Qiu
Zhen Qiu
TTTeresa Zardán Gómez de la Torre
Teresa Zardán Gómez de la Torre
MDMarco Donolato
Marco Donolato
MSMattias Strömberg
Mattias Strömberg
Superstructural assembly of magnetic nanoparticles enables approaches to biosensing by combining specially tailored properties of superstructures and the particular advantages associated with a magnetic or optomagnetic read-out such as low background signal, easy manipulation, cost-efficiency, and potential for bioresponsive multiplexing. Herein, we demonstrate a sensitive and rapid miRNA detection method based on optomagnetic read-out, duplex-specific nuclease (DSN)-assisted target recycling, and the use of multilayer core-satellite magnetic superstructures. Triggered by the presence of target miRNA and DSN-assisted target recycling, the core-satellite magnetic superstructures release their “satellites” to the suspension, which subsequently can be quantified accurately in a low-cost and user-friendly optomagnetic setup. Target miRNAs are preserved in the cleaving reaction and can thereby trigger more cleavage and release of “satellites”. For singleplex detection of let-7b, a linear detection range between 10 fM and 10 nM was observed, and a detection limit of 4.8 fM was obtained within a total assay time of 70 min. Multiplexing was achieved by releasing nanoparticles of different sizes in the presence of different miRNAs. The proposed method also has the advantages of single-nucleotide mismatch discrimination and the ability of quantification in a clinical sample matrix, thus holding great promise for miRNA routine multiplex diagnostics.