Salavat Aglyamov

Dr. Salavat Aglyamov

Department of Mechanical Engineering, University of Houston, TX 77204-4006, USA
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2008 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
JSJignesh Shah
Jignesh Shah
SPSuhyun Park
Suhyun Park
Salavat AglyamovSalavat Aglyamov
Salavat Aglyamov
TLTimothy Larson
Timothy Larson
LMLi Ma
Li Ma
SEStanislav Emelianov
Stanislav Emelianov
Thermal treatments of cancer are an alternative to surgery in cases of small, poorly defined lesions or tumors embedded within vital organs. The primary goal of thermal therapy is to selectively heat a small volume of cancerous cells leading to tumor necrosis while not affecting the surrounding healthy tissue. Cancers of the head and neck, sarcoma, melanoma, lung, breast, bladder, cervix, and liver are suitable candidates for thermal therapy, and early clinical trials show promising results.1, 2

20 May 2013 in Laser Physics Letters
Verified
Journal Article
Closed access
SWShang Wang
Shang Wang
Kirill LarinKirill Larin
Kirill Larin
JLJiasong Li
Jiasong Li
SVS Vantipalli
S Vantipalli
RMR K Manapuram
R K Manapuram
MTM D Twa
M D Twa
Accurate non-invasive assessment of tissue elasticity in vivo is required for early diagnostics of many tissue abnormalities. We have developed a focused air-pulse system that produces a low-pressure and short-duration air stream, which can be used to excite transient surface waves (SWs) in soft tissues. System characteristics were studied using a high-resolution analog pressure transducer to describe the excitation pressure. Results indicate that the excitation pressure provided by the air-pulse system can be easily controlled by the air source pressure, the angle of delivery, and the distance between the tissue surface and the port of the air-pulse system. Furthermore, we integrated this focused air-pulse system with phase-sensitive optical coherence tomography (PhS-OCT) to make non-contact measurements of tissue elasticity. The PhS-OCT system is used to assess the group velocity of SW propagation, which can be used to determine Young’s modulus. Pilot experiments were performed on gelatin phantoms with different concentrations (10%, 12% and 14% w/w). The results demonstrate the feasibility of using this focused air-pulse system combined with PhS-OCT to estimate tissue elasticity. This easily controlled non-contact technique is potentially useful to study the biomechanical properties of ocular and other tissues in vivo.

1 May 2007 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
SSShriram Sethuraman
Shriram Sethuraman
Salavat AglyamovSalavat Aglyamov
Salavat Aglyamov
JAJames Amirian
James Amirian
RSRichard Smalling
Richard Smalling
SEStanislav Emelianov
Stanislav Emelianov
Catheter-based imaging of atherosclerosis with high resolution, albeit invasive, is extremely important for screening and characterization of vulnerable plaques. Currently, there is a need for an imaging technique capable of providing comprehensive morphological and functional information of plaques. In this paper, we present an intravascular photoacoustic imaging technique to characterize vulnerable plaques by using optical absorption contrast between normal tissue and atherosclerotic lesions. Specifically, we investigate the feasibility of obtaining intravascular photoacoustic (IVPA) images using a high-frequency intravascular ultrasound (IVUS) imaging catheter. Indeed, the combination of IVPA imaging with clinically available IVUS imaging may provide desired functional and morphological assessment of the plaque. The imaging studies were performed with tissue-mimicking arterial vessel phantoms and excised samples of rabbit artery. The results of our study suggest that catheter-based intravascular photoacoustic imaging is possible, and the combination of IVPA with IVUS has the potential to detect and differentiate atherosclerosis based on both the structure and composition of the plaque

23 November 2011 in Small
Verified
Journal Article
Closed access
PDF file
YCYun‐Sheng Chen
Yun‐Sheng Chen
WFWolfgang Frey
Wolfgang Frey
Salavat AglyamovSalavat Aglyamov
Salavat Aglyamov
SEStanislav Emelianov
Stanislav Emelianov

1 February 2015 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
Zhaolong HanZhaolong Han
Zhaolong Han
Salavat AglyamovSalavat Aglyamov
Salavat Aglyamov
JLJiasong Li
Jiasong Li
Rashim SinghRashim Singh
Rashim Singh
SWShang Wang
Shang Wang
Kirill LarinKirill Larin
Kirill Larin
We demonstrate the use of a modified Rayleigh–Lamb frequency equation in conjunction with noncontact optical coherence elastography to quantify the viscoelastic properties of the cornea. Phase velocities of air-pulse-induced elastic waves were extracted by spectral analysis and used for calculating the Young’s moduli of the samples using the Rayleigh–Lamb frequency equation (RLFE). Validation experiments were performed on 2% agar phantoms (n=3) and then applied to porcine corneas (n=3) in situ. The Young’s moduli of the porcine corneas were estimated to be ∼60  kPa with a shear viscosity ∼0.33  Pa·s. The results demonstrate that the RLFE is a promising method for noninvasive quantification of the corneal biomechanical properties and may potentially be useful for clinical ophthalmological applications.

4 June 2008 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SPSuhyun Park
Suhyun Park
AKAndrei B. Karpiouk
Andrei B. Karpiouk
Salavat AglyamovSalavat Aglyamov
Salavat Aglyamov
SEStanislav Emelianov
Stanislav Emelianov
An adaptive photoacoustic image reconstruction technique that combines coherence factor (CF) weighting and the minimum variance (MV) method is introduced. The backprojection method is widely used to reconstruct photoacoustic tomography images. Owing to the scattering of light, the quality of the photoacoustic imaging can be degraded. CF, an adaptive weighting technique, is known to improve the lateral resolution of photoacoustic images. In addition, an MV adaptive beamforming method can further improve the image quality by suppressing signals from off-axis directions. Experimental studies are performed to quantify the spatial resolution and contrast of the adaptive photoacoustic beamforming methods.