Thananchai Leephakpreeda

Dr. Thananchai Leephakpreeda

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2008 in Expert Systems with Applications
Verified
Journal Article
Closed access
TLThananchai Leephakpreeda
Thananchai Leephakpreeda

10 August 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TNThanana Nuchkrua
Thanana Nuchkrua
TLThananchai Leephakpreeda
Thananchai Leephakpreeda
In this article, a pneumatic artificial muscle (PAM) based on a metal hydride (MH) is considered for a compact compliant actuator. It is suitable for broad applications of the human–robot interaction (HRI). To address the problem of the HRI represented by a varying environment, a compliant control is introduced. In fact, the bottlenecks of improving the performance in the compliant control of the PAM actuator are: an inherent nonlinear dynamics of a PAM, the parametric and nonlinear uncertainties influenced by a varying environment, and an additional high dimension introduced by an MH employed as a driving force for the PAM. We propose a learning-based adaptive robust control (LARC) framework to tackle these challenges. A Bayesian learning technique deals with the parameter adaptation for the adaptive control. The effectiveness of the LARC has been examined in extensive experiments of tracking control.

21 December 2010 in Expert Systems with Applications
Verified
Journal Article
Closed access
TLThananchai Leephakpreeda
Thananchai Leephakpreeda

1 March 2012 in ISA Transactions
Verified
Journal Article
Closed access
TLThananchai Leephakpreeda
Thananchai Leephakpreeda

14 August 2018 in International Journal of Clothing Science and Technology
Verified
Journal Article
Closed access
KOKrittiya Ongwuttiwat
Krittiya Ongwuttiwat
SSSudaporn Sudprasert
Sudaporn Sudprasert
TLThananchai Leephakpreeda
Thananchai Leephakpreeda
Purpose: The purpose of this paper is to present the determination of human thermal comfort with wearing clothes, with different water vapor permeability. Currently, the predicted mean vote (PMV) equation is widely used to determine thermal sensation scales of human comfort. However, moisture permeability of clothes has been not taken in account where the heat is lost from a human body due to water vapor diffusion through clothes. Design/methodology/approach: In this study, the heat loss is derived based on the real structure of textiles, causing water vapor pressure difference between air on skin and ambient air. The PMV equation is modified to differentiate a thermal sensation scale of comfort although patterns of clothes are the same. Interview tests are investigated with wearing clothes from three types of textiles: knitted polyester, coated nylon–spandex, and polyurethane, under various air conditions. Findings: The moisture permeabilities of knitted polyester, coated nylon–spandex and polyurethane are 16.57×10−9 kg/m2 s•kPa, 9.15×10−9 kg/m2•s•kPa and 2.99×10−9 kg/m2•s•kPa, respectively. The interviews reveal that most people wearing knitted-polyester clothes have the greatest cold sensations under various air conditions since moisture permeability is the highest, compared to coated nylon–spandex, and polyurethane leather. Correspondingly, the predicted results of the modified PMV equation are close to the actual mean votes of interviewees with a coefficient of determination R2=0.83. On the other hand, the coefficient of determination from the predicted results of the conventional PMV equation is significantly lower than unity, with R2=0.42. Practical implications: In practice, this quantitative determination on human thermal comfort gives some concrete recommendations on textile selection of clothes for acceptable satisfaction of thermal comfort under various surrounding conditions of usage. Originality/value: The modified PMV equation effectively determines human comfort on a thermal sensation scale due to the moisture permeability of clothes. To make generic conclusion, experimental results of additional three textiles, such as plain weave/lining polyester, knitted spandex, and open structure polyester, are reported. They confirm that the modified PMV equation effectively determines human comfort on a thermal sensation scale due to the moisture permeability of clothes.