Thierry Castermans

Dr. Thierry Castermans


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
MDMatthieu Duvinage
Matthieu Duvinage
TCThierry Castermans
Thierry Castermans
MPMathieu Petieau
Mathieu Petieau
THThomas Hoellinger
Thomas Hoellinger
Guy CHERONGuy CHERON
Guy CHERON
TDThierry Dutoit
Thierry Dutoit
For two decades, EEG-based Brain-Computer Interface (BCI) systems have been widely studied in research labs. Now, researchers want to consider out-of-the-lab applications and make this technology available to everybody. However, medical-grade EEG recording devices are still much too expensive for end-users, especially disabled people. Therefore, several low-cost alternatives have appeared on the market. The Emotiv Epoc headset is one of them. Although some previous work showed this device could suit the customer’s needs in terms of performance, no quantitative classification-based assessments compared to a medical system are available. This paper aims at statistically comparing a medical-grade system, the ANT device, and the Emotiv Epoc headset by determining their respective performances in a P300 BCI using the same electrodes. On top of that, a review of previous Emotiv studies and a discussion on practical considerations regarding both systems are proposed. Nine healthy subjects participated in this experiment during which the ANT and the Emotiv systems are used in two different conditions: sitting on a chair and walking on a treadmill at constant speed. The Emotiv headset performs significantly worse than the medical device; observed effect sizes vary from medium to large. The Emotiv headset has higher relative operational and maintenance costs than its medical-grade competitor. Although this low-cost headset is able to record EEG data in a satisfying manner, it should only be chosen for non critical applications such as games, communication systems, etc. For rehabilitation or prosthesis control, this lack of reliability may lead to serious consequences. For research purposes, the medical system should be chosen except if a lot of trials are available or when the Signal-to-Noise Ratio is high. This also suggests that the design of a specific low-cost EEG recording system for critical applications and research is still required.

1 February 2014 in Neuroscience Letters
Verified
Journal Article
Closed access
TCThierry Castermans
Thierry Castermans
MDMatthieu Duvinage
Matthieu Duvinage
GCGuy Cheron
Guy Cheron
TDThierry Dutoit
Thierry Dutoit

31 December 2013 in Brain Sciences
Verified
Journal Article
Open access
PDF file
TCThierry Castermans
Thierry Castermans
MDMatthieu Duvinage
Matthieu Duvinage
Guy CHERONGuy CHERON
Guy CHERON
TDThierry Dutoit
Thierry Dutoit
In the last few years, significant progress has been made in the field of walk rehabilitation. Motor cortex signals in bipedal monkeys have been interpreted to predict walk kinematics. Epidural electrical stimulation in rats and in one young paraplegic has been realized to partially restore motor control after spinal cord injury. However, these experimental trials are far from being applicable to all patients suffering from motor impairments. Therefore, it is thought that more simple rehabilitation systems are desirable in the meanwhile. The goal of this review is to describe and summarize the progress made in the development of non-invasive brain-computer interfaces dedicated to motor rehabilitation systems. In the first part, the main principles of human locomotion control are presented. The paper then focuses on the mechanisms of supra-spinal centers active during gait, including results from electroencephalography, functional brain imaging technologies [near-infrared spectroscopy (NIRS), functional magnetic resonance imaging (fMRI), positron-emission tomography (PET), single-photon emission-computed tomography (SPECT)] and invasive studies. The first brain-computer interface (BCI) applications to gait rehabilitation are then presented, with a discussion about the different strategies developed in the field. The challenges to raise for future systems are identified and discussed. Finally, we present some proposals to address these challenges, in order to contribute to the improvement of BCI for gait rehabilitation.

22 December 2011 in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
Verified
Journal Article
Closed access
TCThierry Castermans
Thierry Castermans
MDMatthieu Duvinage
Matthieu Duvinage
MPMathieu Petieau
Mathieu Petieau
THThomas Hoellinger
Thomas Hoellinger
CSCaty De Saedeleer
Caty De Saedeleer
TDThierry Dutoit
Thierry Dutoit
Brain-computer interfaces (BCIs) enable their users to interact with their surrounding environment using the activity of their brain only, without activating any muscle. This technology provides severely disabled people with an alternative mean to communicate or control any electric device. On the other hand, BCI applications are more and more dedicated to healthier people, with the aim of giving them access to augmented reality or new rehabilitation tools. As it is noninvasive, light and relatively cheap, electroencephalography (EEG) is the most used acquisition technique to record cerebral activity of the BCI users. However, when using such type of BCI, user movements are likely to provoke motions of the measuring electrodes which can severely damage the EEG quality. Thus, current BCI technology requires that the user sits and performs as little movements as possible. This is of course a strong limitation of BCI for use in ordinary life. Very recently, preliminary studies have been published in the literature and suggest that BCI applications can be realized even in the physically moving context. In this paper, we thoroughly investigate the possibility to develop a P300-based BCI system in ambulatory condition. The study is based on experimental data recorded with seven subjects executing a visual P300 speller-like discrimination task while simultaneously walking at different speeds on a treadmill. It is demonstrated that a P300-based BCI is definitely feasible in such conditions. Different artifact correction methods are described and discussed in detail. To conclude, a recommended approach is given for the development of a real-time application.

1 January 2013 in Frontiers in Computational Neuroscience
Verified
Journal Article
Open access
PDF file
THThomas Hoellinger
Thomas Hoellinger
MPMathieu Petieau
Mathieu Petieau
MDMatthieu Duvinage
Matthieu Duvinage
TCThierry Castermans
Thierry Castermans
KSKarthik Seetharaman
Karthik Seetharaman
Guy CHERONGuy CHERON
Guy CHERON
The existence of dedicated neuronal modules such as those organized in the cerebral cortex, thalamus, basal ganglia, cerebellum, or spinal cord raises the question of how these functional modules are coordinated for appropriate motor behavior. Study of human locomotion offers an interesting field for addressing this central question. The coordination of the elevation of the 3 leg segments under a planar covariation rule (Borghese et al., 1996) was recently modeled (Barliya et al., 2009) by phase-adjusted simple oscillators shedding new light on the understanding of the central pattern generator (CPG) processing relevant oscillation signals. We describe the use of a dynamic recurrent neural network (DRNN) mimicking the natural oscillatory behavior of human locomotion for reproducing the planar covariation rule in both legs at different walking speeds. Neural network learning was based on sinusoid signals integrating frequency and amplitude features of the first three harmonics of the sagittal elevation angles of the thigh, shank, and foot of each lower limb. We verified the biological plausibility of the neural networks. Best results were obtained with oscillations extracted from the first three harmonics in comparison to oscillations outside the harmonic frequency peaks. Physiological replication steadily increased with the number of neuronal units from 1 to 80, where similarity index reached 0.99. Analysis of synaptic weighting showed that the proportion of inhibitory connections consistently increased with the number of neuronal units in the DRNN. This emerging property in the artificial neural networks resonates with recent advances in neurophysiology of inhibitory neurons that are involved in central nervous system oscillatory activities. The main message of this study is that this type of DRNN may offer a useful model of physiological central pattern generator for gaining insights in basic research and developing clinical applications.

15 March 2013 in The Journal of Physiology
Verified
Journal Article
Open access
PDF file
TCThierry Castermans
Thierry Castermans
MDM. Duvinage
M. Duvinage