Li Tao

Li Tao


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2009 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
LTLi Tao
Li Tao
YCYanhong Chen
Yanhong Chen
JMJan Ma
Jan Ma
A 421 kHz miniaturized piezoelectric ultrasonic transducer for portable and internal body therapeutic applications was developed. The weight, outer diameter, and length of the transducer are 0.15 g, 2 mm, and 10.35 mm, respectively. The transducer is a one-wavelength design based on the longitudinal vibration mode with a stepped horn to focus the energy. Finite element analysis and equivalent circuit models were applied for theoretical analysis. Qm and keff of the transducer measured using the impedance analyzer were 393 and 0.21, respectively. The acoustic output properties of the transducer were measured based on the hydrophone measurements under the condition of 1/4lambda immersion depth. The maximum input electrical power, output acoustic power, sound intensity, radiation pressure, and vibration velocity at the radiation surface were derived to be 0.45 W, 0.11 W, 38 W/cm2, 1.8 MPa, and 2.7 m/s, respectively. The directivity pattern shows that the pressure distribution is omnidirectional within the range from 30 to 150 degrees. The nonlinear effects of ultrasonic streaming in water and cavitation in silicone oil due to the intense ultrasound were also observed. The potential applications of the transducer are sonodynamic therapy, drug delivery, and microfluidic pumping.

1 July 2005 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
LTLi Tao
Li Tao
YCY. H. Chen
Y. H. Chen
JMJ. Ma
J. Ma

8 February 2007 in Journal of Electroceramics
Verified
Journal Article
Closed access
PDF file
LTLi Tao
Li Tao
YCY. H. Chen
Y. H. Chen
FBF. Y. C. Boey
F. Y. C. Boey
JMJ. Ma
J. Ma

11 January 2019 in Actuators
Verified
Journal Article
Open access
PDF file
LTLi Tao
Li Tao
Pooi See LeePooi See Lee
Pooi See Lee
A piezoelectric energy harvester was developed in this paper. It is actuated by the vibration leakage from the nodal position of a high-power ultrasonic cutting transducer. The harvester was excited at a low displacement amplitude (0.73 µmpp). However, its operation frequency is quite high and reaches the ultrasonic range (24.4 kHz). Compared with another low frequency harvester (66 Hz), both theoretical and experimental results proved that the advantages of this high frequency harvester include (i) high current generation capability (up to 20 mApp compared to 1.3 mApp of the 66 Hz transducer) and (ii) low impedance matching resistance (500 Ω in contrast to 50 kΩ of the 66 Hz transducer). This energy harvester can be applied either in sensing, or vibration controlling, or simply energy harvesting in a high-power ultrasonic system.

14 July 2006 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
LTLi Tao
Li Tao
YCY.H. Chen
Y.H. Chen
FBF.Y.C. Boey
F.Y.C. Boey
JMJ. Ma
J. Ma

15 May 2012 in ISRN Materials Science
Verified
Journal Article
Open access
PDF file
LTLi Tao
Li Tao
JMJan Ma
Jan Ma
SKS. Dinesh Kumar
S. Dinesh Kumar
ALAdrian F. Low
Adrian F. Low
Ultrasonic thrombolysis is an effective method to treat blood clot thrombus in a blood vessel. This paper reports an OD 5 mm and an OD 10 mm piezoelectric thrombolysis transducers that vibrate longitudinally and generate a pressure field at the distal vibration tip. Studies of vibration mode, pressure field pattern, and cavitation effect were carried out. The transducers were also tested for blood clot emulsification. The results indicate both transducers are effective. The OD 10 mm transducer with a long transmission wire has shown to provide a strong cavitation effect and work effectively at low frequency, high amplitude, and high power conditions. The OD 5 mm transducer was found to operate effectively under higher frequency, low amplitude, and lower power conditions. The cavitation effect is moderate, which facilitates precision and controls over obtaining a more uniform emulsification result.