Maria Marcella Laganà

Dr. Maria Marcella Laganà

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2021 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
JCJulien Cohen-Adad
Julien Cohen-Adad
EAEva Alonso-Ortiz
Eva Alonso-Ortiz
MAMihael Abramovic
Mihael Abramovic
CACarina Arneitz
Carina Arneitz
NANicole Atcheson
Nicole Atcheson
JXJunqian Xu
Junqian Xu

21 March 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ODOttavia Dipasquale
Ottavia Dipasquale
ASArjun Sethi
Arjun Sethi
MLMaria Marcella Laganà
Maria Marcella Laganà
FBFrancesca Baglio
Francesca Baglio
GBGiuseppe Baselli
Giuseppe Baselli
MCMara Cercignani
Mara Cercignani
Artifact removal in resting state fMRI (rfMRI) data remains a serious challenge, with even subtle head motion undermining reliability and reproducibility. Here we compared some of the most popular single-echo de-noising methods—regression of Motion parameters, White matter and Cerebrospinal fluid signals (MWC method), FMRIB’s ICA-based X-noiseifier (FIX) and ICA-based Automatic Removal Of Motion Artifacts (ICA-AROMA)—with a multi-echo approach (ME-ICA) that exploits the linear dependency of BOLD on the echo time. Data were acquired using a clinical scanner and included 30 young, healthy participants (minimal head motion) and 30 Attention Deficit Hyperactivity Disorder patients (greater head motion). De-noising effectiveness was assessed in terms of data quality after each cleanup procedure, ability to uncouple BOLD signal and motion and preservation of default mode network (DMN) functional connectivity. Most cleaning methods showed a positive impact on data quality. However, based on the investigated metrics, ME-ICA was the most robust. It minimized the impact of motion on FC even for high motion participants and preserved DMN functional connectivity structure. The high-quality results obtained using ME-ICA suggest that using a multi-echo EPI sequence, reliable rfMRI data can be obtained in a clinical setting.

16 August 2021 in Scientific Data
Verified
Journal Article
Open access
PDF file
JCJulien Cohen-Adad
Julien Cohen-Adad
EAEva Alonso-Ortiz
Eva Alonso-Ortiz
MAMihael Abramovic
Mihael Abramovic
CACarina Arneitz
Carina Arneitz
NANicole Atcheson
Nicole Atcheson
JXJunqian Xu
Junqian Xu
In a companion paper by Cohen-Adadet al. we introduce thespine genericquantitative MRI protocol that provides valuable metrics for assessing spinal cord macrostructural and microstructural integrity. This protocol was used to acquire a single subject dataset across 19 centers and a multi-subject dataset across 42 centers (for a total of 260 participants), spanning the three main MRI manufacturers: GE, Philips and Siemens. Both datasets are publicly available via git-annex. Data were analysed using the Spinal Cord Toolbox to produce normative values as well as inter/intra-site and inter/intra-manufacturer statistics. Reproducibility for thespine genericprotocol was high across sites and manufacturers, with an average inter-site coefficient of variation of less than 5% for all the metrics. Full documentation and results can be found athttps://spine-generic.rtfd.io/. The datasets and analysis pipeline will help pave the way towards accessible and reproducible quantitative MRI in the spinal cord.

1 January 2020 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
EHEwart Mark Haacke
Ewart Mark Haacke
Yongsheng ChenYongsheng Chen
Yongsheng Chen
DUDavid Utriainen
David Utriainen
BWBo Wu
Bo Wu
YWYu Wang
Yu Wang
FYFuhua Yan
Fuhua Yan

7 April 2018 in Journal of Neurology
Verified
Journal Article
Closed access
ETEleonora Tavazzi
Eleonora Tavazzi
NBNiels Bergsland
Niels Bergsland
DCDavide Cattaneo
Davide Cattaneo
EGElisa Gervasoni
Elisa Gervasoni
MLMaria Marcella Laganà
Maria Marcella Laganà
MRMarco Rovaris
Marco Rovaris

11 August 2015 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
PDF file
LGLudovica Griffanti
Ludovica Griffanti
ODOttavia Dipasquale
Ottavia Dipasquale
MLMaria Marcella Laganà
Maria Marcella Laganà
RNRaffaello Nemni
Raffaello Nemni
mario clericimario clerici
mario clerici
FBFrancesca Baglio
Francesca Baglio
Artefact removal from resting state fMRI data is an essential step for a better identification of the resting state networks and the evaluation of their functional connectivity (FC), especially in pathological conditions. There is growing interest in the development of cleaning procedures, especially those not requiring external recordings (data-driven), which are able to remove multiple sources of artefacts. It is important that only inter-subject variability due to the artefacts is removed, preserving the between-subject variability of interest - crucial in clinical applications using clinical scanners to discriminate different pathologies and monitor their staging. In Alzheimer’s disease (AD) patients, decreased FC is usually observed in the posterior cingulate cortex within the default mode network (DMN), and this is becoming a possible biomarker for AD. The aim of this study was to compare four different data-driven cleaning procedures (regression of motion parameters; regression of motion parameters, mean white matter and cerebrospinal fluid signal; FMRIB's ICA-based X-noiseifier –FIX- cleanup with soft and aggressive options) on data acquired at 1.5T. The approaches were compared using data from 20 elderly healthy subjects and 21 AD patients in a mild stage, in terms of their impact on within-group consistency in FC and ability to detect the typical FC alteration of the DMN in AD patients. Despite an increased within-group consistency across subjects after applying any of the cleaning approaches, only after cleaning with FIX the expected DMN FC alteration in AD was detectable. Our study validates the efficacy of artefact removal even in a relatively small clinical population, and supports the importance of cleaning fMRI data for sensitive detection of FC alterations in a clinical environment.