Edson Guedes Da Costa

Dr. Edson Guedes Da Costa

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2009 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
ECEdson Guedes Da Costa
Edson Guedes Da Costa
TFTarso V. Ferreira
Tarso V. Ferreira
MNMax G.G. Neri
Max G.G. Neri
IQIsaac B. Queiroz
Isaac B. Queiroz
AGAndre D. Germano
Andre D. Germano
This paper presents an efficient monitoring methodology for polymeric insulators. The experiments allow that the correlation of internal and external temperatures of the insulators be implemented. Clean and polluted insulators were also inspected with infrared and ultraviolet cameras, and the influence of well dimensioned corona rings under polluted conditions was evaluated. The electrical behavior of the insulators and corona rings was estimated in simulations using the Finite Element Method.

31 January 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
GXGeorge Xavier
George Xavier
ECEdson Guedes Da Costa
Edson Guedes Da Costa
ASAlexandre J. R. Serres
Alexandre J. R. Serres
LNLuiz Augusto Medeiros Martins Nobrega
Luiz Augusto Medeiros Martins Nobrega
AOAdriano Oliveira
Adriano Oliveira
HSHerbet F. S. Sousa
Herbet F. S. Sousa
In this paper, the design and application of a circular microstrip antenna for partial discharge detection is presented. For this purpose, the truncated ground plane technique was applied for the bandwidth enhancement. In addition, aiming at an optimized structure, the computational simulations with several combinations of the antenna dimensional parameters were performed. In order to verify whether the developed antenna met the prerequisites (bandwidth and gain) for practical application in partial discharge detection, the optimized antenna was subjected to tests in an anechoic chamber. Finally, the antenna sensitivity was compared with the IEC 60270 standard method. For this purpose, the simultaneous tests were carried out in a partial discharge generator arrangement composed of an oil cell with point-to-plane and plane-to-plane electrode configurations. The developed antenna can detect apparent charge values higher than 30 pC and has an average gain greater than 2 dB along its bandwidth. The obtained results attested to the potential of the developed antenna for the development of UHF sensors for partial discharge detection in high-voltage equipment.

15 May 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
VBValdemir S. Brito
Valdemir S. Brito
GLGeorge Lira
George Lira
ECEdson Guedes Da Costa
Edson Guedes Da Costa
MMMarcelo J. A. Maia
Marcelo J. A. Maia
This paper presents an electric model of a metal-oxide surge arrester (MOSA). The proposed electric model accurately represents the MOSA in a wide range of frequencies and amplitudes. The model was developed and validated based on MOSA electrical behavior in each one of the three operating regions of the zinc-oxide (ZnO) surge arresters, and in a database composed of voltage and current waveforms measured from tests performed in 12 ZnO varistors having different physical dimensions and electrical characteristics-from five different manufacturers. These varistors were subjected to different voltage levels in the low current region, and multilevel amplitude of switching current impulses (30/60 μs), lightning current impulses (8/20 μs), high current impulses (4/10 μs), and fast-front current impulses (1.5/26 μs and 3/6 μs) encompass the three regions of operation and a wide range of frequencies and amplitudes. The results provided by the MOSA wide-range (MWR) model were compared with those obtained in the laboratory. The MWR model has shown good agreement in terms of waveform, peak value, and absorbed energy for the evaluated cases.

4 March 2009 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ENE. T. Wanderley Neto
E. T. Wanderley Neto
ECEdson Guedes Da Costa
Edson Guedes Da Costa
MMM. J. A. Maia
M. J. A. Maia
Lightning arresters provide protection for transmission lines and power equipments. During the occurrence of lightning or switching surges, a voltage level above the equipment insulation level can be reached. An arrester, properly working, is able to limit this voltage level avoiding damages to the protected equipment. A defective arrester may not be able to provide the proper protection level in substations, exposing the equipment and personnel to damage. Monitoring of surge arresters is usually conducted by means of current measurement or thermal images acquisition. But, among power companies, there is no model procedure for the monitoring conduction and analysis of the obtained results. Besides that, when some abnormality is detected, the arrester is replaced by a new one and no further study is conducted to evaluate what kind of problem happened to it. This work proposes a method for analysis of ZnO arresters by the study of failures and usage of artificial neural networks-ANN. The ANN is able to analyze the thermal profile, detect and classify patterns that could be undetected by a visual analysis.

1 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JCJosiel Cruz
Josiel Cruz
ALEXANDRE SERRESALEXANDRE SERRES
ALEXANDRE SERRES
AOAdriano Oliveira
Adriano Oliveira
GXGeorge Xavier
George Xavier
CACamila Albuquerque
Camila Albuquerque
RFRaimundo Carlos Silvério Freire
Raimundo Carlos Silvério Freire
A new, bio-inspired printed monopole antenna (PMA) model is applied to monitor partial discharge (PD) activity in high voltage insulating systems. An optimized sensor was obtained by designing a PMA in accordance with the characteristics of the electromagnetic signal produced by PD. An ultra-wideband (UWB) antenna was obtained by applying the truncated ground plane technique. The patch geometry was bio-inspired by that of the Inga Marginata leaf, resulting in a significant reduction in size. To verify the operating frequency and gain of the PMA, measurements were carried out in an anechoic chamber. The results show that the antenna operating bandwidth covers most of the frequency range of PD occurrence. Moreover, the antenna presented a good sensitivity (mean gain of 3.63 dBi). The antenna performance was evaluated through comparative results with the standard IEC 60270 method. For this purpose, simultaneous tests were carried out in a PD generator arrangement, composed by an oil cell with point-to-plane electrode configurations. The developed PMA can be classified as an optimized sensor for PD detection and suitable for substation application, since it is able to measure PD radiated signals with half the voltage levels obtained from the IEC method and is immune to corona discharges.

5 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LNLuiz Augusto Medeiros Martins Nobrega
Luiz Augusto Medeiros Martins Nobrega
GXGeorge Xavier
George Xavier
MAMarcus V. D. Aquino
Marcus V. D. Aquino
ALEXANDRE SERRESALEXANDRE SERRES
ALEXANDRE SERRES
CACamila Albuquerque
Camila Albuquerque
ECEdson Guedes Da Costa
Edson Guedes Da Costa
In this paper, the design and development of a bio-inspired UHF sensor for partial discharge detection in power transformers is presented. The UHF sensor was developed for external use in dielectric windows of power transformers. For this purpose, a microstrip antenna was designed with a radiating element shape based on the leaf of the Jatropha mollissima (Pohl) Baill plant. Then, an epoxy coating and an aluminium enclosure were developed to protect the antenna against corrosion and to provide mechanical support, external noise immunity, and a lifetime compatibility with power transformers. In order to verify the electrical parameters of the developed sensor, measurements of the gain and the reflection coefficient were performed in an anechoic chamber. Lastly, the antenna sensitivity for denominated partial discharge (PD) detection was compared with the IEC 60270 standard method. For this purpose, simultaneous tests were carried out in a partial discharge generator setup, composed of an oil cell with needle-plane electrodes. The experimental tests demonstrated the effectiveness of the sensor for detecting PD signals with apparent charge values higher than 35 pC.