Wiktor Lorenc

Dr. Wiktor Lorenc

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Chemosphere
Verified
Journal Article
Closed access
IKIzabela Komorowicz
Izabela Komorowicz
AHAnetta Hanć
Anetta Hanć
WLWiktor Lorenc
Wiktor Lorenc
Danuta BarałkiewiczDanuta Barałkiewicz
Danuta Barałkiewicz
Jerzy FalandyszJerzy Falandysz
Jerzy Falandysz
YWYuanzhong Wang
Yuanzhong Wang

1 June 2021 in Environmental Research
Verified
Journal Article
Closed access
MSMarta Szukalska
Marta Szukalska
TMThurman Allen Merritt
Thurman Allen Merritt
WLWiktor Lorenc
Wiktor Lorenc
KSKatarzyna Sroczyńska
Katarzyna Sroczyńska
IMIzabela Miechowicz
Izabela Miechowicz
EFEwa Florek
Ewa Florek


10 August 2018 in Biological Trace Element Research
Verified
Journal Article
Open access
PDF file
RKRafał Kocyłowski
Rafał Kocyłowski
MGMariusz Grzesiak
Mariusz Grzesiak
ZGZuzanna Gaj
Zuzanna Gaj
WLWiktor Lorenc
Wiktor Lorenc
EBEwa Bakinowska
Ewa Bakinowska
Joanna SuliburskaJoanna Suliburska
Joanna Suliburska
The objective of this study was to determine the concentration and the reference ranges of essential and toxic elements in amniotic fluid (AF) and maternal serum (MS) at birth. This study was conducted among 175 healthy pregnant Caucasian European women aged 18–42. AF and maternal blood samples were collected during delivery. An inductively coupled plasma mass spectrometry (ICP-MS) technique was used to determine the levels of Mg, Co, Cu, Zn, Sr, Cd, Ba, Pb, U, Ca, Cr, Al, Mn, V, Fe, As, Se and Sb in AF and MS. The range of reference values was calculated for all analyzed elements in the serum and AF. The mean concentrations of elements, except Pb, were generally higher in MS than in AF. Multiple regression analysis showed that the maternal/newborn body mass (MBM/NBM) ratio was a strong negative predictor (among maternal age and gravidity) of Mg concentration in amniotic fluid. In the serum, MBN/NBM ratio was a strong positive predictor of Cu concentration. Moreover, regression analysis showed that maternal age was an independent positive predictor of the Se level in maternal serum. The reference value ranges of 18 essential and toxic elements were established in AF and MS among a population of healthy pregnant Polish women at delivery. The level of Mg, Co, Cu, Ca and Se in AF and MS can be determined by maternal age and MBM/NBM ratio. These results can be useful in counseling individuals with pregnancies affected by exposure to one of the parameters under investigation.


14 February 2019 in Molecules
Verified
Journal Article
Open access
PDF file
WLWiktor Lorenc
Wiktor Lorenc
BMBarbara Markiewicz
Barbara Markiewicz
DKDariusz Kruszka
Dariusz Kruszka
PKPiotr Kachlicki
Piotr Kachlicki
Danuta BarałkiewiczDanuta Barałkiewicz
Danuta Barałkiewicz
The main aim of the research was to develop a complementary analytical approach consisting of bespoke speciation analysis and non-targeted speciation analysis of As, Sb, and Cr in flavored bottled drinking water samples using HPLC/ICP-DRC-MS and ESI-MS/MS. The scope of two previously developed analytical procedures, (1) multielemental speciation procedure for AsIII, AsV, CrVI, SbIII, and SbV analysis and (2) arsenic speciation procedure for AsB, AsIII, DMA, MMA, and AsV quantification, was extended to the analysis of a new sample type in terms of bespoke speciation analysis. As for the non-targeted speciation, analysis size exclusion chromatography was used with ICP-MS and a complementary technique, ESI-MS/MS, was used for the organic species of As, Sb, and Cr screening. Full validation of procedures 1 and 2 was conducted. Procedure 1 and 2 were characterized with precision values in the range from 2.5% to 5.5% and from 3.6% to 7.2%, respectively. Obtained recoveries ranged from 97% to 106% and from 99% to 106% for procedures 1 and 2, respectively. Expanded uncertainties calculated for procedures 1 and 2 ranged from 6.1% to 9.4% and from 7.4% to 9.9%, respectively. The applicability of the proposed procedures was tested on bottled drinking water samples. Results for the real samples in procedure 1 were in the range from 0.286 ± 0.027 [μg L−1] to 0.414 ± 0.039 [μg L−1] for AsIII, from 0.900 ± 0.083 [μg L−1] to 3.26 ± 0.30 [μg L−1] for AsV, and from 0.201 ± 0.012 [μg L−1] to 0.524 ± 0.032 [μg L−1] for SbV. CrVI and SbIII were not detected in any sample. As for procedure 2, results were in the range from 0.0541 ± 0.0053 [μg L−1] to 0.554 ± 0.054 [μg L−1] for AsB. Results for AsIII and AsV obtained with procedure 2 were in good accordance with results obtained with procedure 1. DMA and MMA were not detected in any sample.