CHENMENG ZHANG

Dr. CHENMENG ZHANG


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SXshijun xie
shijun xie
YZYu Zhang
Yu Zhang
HYHuaiyuan Yang
Huaiyuan Yang
HYHao Yu
Hao Yu
ZMZhou Mu
Zhou Mu
RHRuorong Hua
Ruorong Hua
Transient voltages in the power grid are the key for the fault analysis of a power grid, optimized insulation design, and the standardization of the high-voltage testing method. The traditional measuring equipment, based on electrical engineering, normally has a limited bandwidth and response speed, which are also featured by a huge size and heavy weight. In this paper, an integrated optical electric-field sensor based on the Pockels effect was developed and applied to measure the transient voltages on the high-voltage conductors in a non-contact measuring mode. The measuring system has a response speed faster than 6 ns and a wide bandwidth ranging from 5 Hz to 100 MHz. Moreover, the sensors have the dimensions of 18 mm by 18 mm by 48 mm and a light weight of dozens of grams. The measuring systems were employed to monitor the lightning transient voltages on a 220 kV overhead transmission line. The switching transient voltages were also measured by the measuring system during the commissioning of the 500 kV middle Tibet power grid. In 2017, 307 lightning transient voltages caused by induction stroke were recorded. The characteristics of these voltage waveforms are different from the standard lightning impulse voltage proposed by IEC standards. Three types of typical switching transient voltage in 500 kV AC power grid were measured, and the peak values of these overvoltages can reach 1.73 times rated voltage.

8 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
DLDonghui Luo
Donghui Luo
YCYongxing Cao
Yongxing Cao
YZYu Zhang
Yu Zhang
SXshijun xie
shijun xie
CZCHENMENG ZHANG
CHENMENG ZHANG
SCShuping Cao
Shuping Cao
The transient analysis model of grounding systems is an important tool to analyze the lightning characteristics of grounding devices. When lightning enters the soil through the grounding device, there is a centralized discharge channel. The spatial structure of the discharge channel in the soil has a great effect on the accuracy of the transient analysis model of the soil impulse discharge. In this paper, based on the gray information analysis method, the volume of successive impulse discharge channels in the ground under various currents and soil conditions is calculated, and the changing law with time interval is analyzed. According to the experimental results, an analysis method of the model considering the discharge channel structure is proposed, and an example is analyzed. The results show that the time interval has an effect on the volume of the discharge channel. In a certain range, the volume of the channel increases with the time interval of successive impulse discharges. Taking the critical breakdown electric field strength as the judgment condition and the residual resistivity as the variable, the development process of the discharge channel can be simulated. The calculated results of the model are close to the experimental results.

29 March 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
CZCHENMENG ZHANG
CHENMENG ZHANG
YMYuxiang Mao
Yuxiang Mao
SXShijun Xie
Shijun Xie
YZYu Zhang
Yu Zhang
The electric field of power capacitors with different typical defects in DC working condition and impulse oscillation working condition is studied in this paper. According to the type and location of defects and considering the influence of space charge, two-dimensional models of surge capacitors with different typical defects are simulated based on ANSYS. The distribution of the electric field inside the capacitor is analyzed, and the concentration of electric field and its influence on the insulation performance are obtained. The results show that the type of defects, the location of defects and the space charge all affect the electric field distribution inside the capacitor in varying degrees. Especially the electric field distortion in the local area such as sharp corners and burrs is relatively larger, which increases the probability of partial discharge inside the surge capacitor.

29 March 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
CZCHENMENG ZHANG
CHENMENG ZHANG
SXShijun Xie
Shijun Xie
YZYu Zhang
Yu Zhang
YMYuxiang Mao
Yuxiang Mao
Surge capacitors running between the natural bus and the ground are affected by DC and impulse superposition voltage during operation in the converter station. This paper analyses the simulation aging circuit of surge capacitors by PSCAD electromagnetic transient simulation software. This paper also analyses the effect of the DC voltage to the waveform of the impulse voltage generation. The effect of coupling capacitor to the test voltage waveform is also studied. Testing results prove that the DC voltage has little effect on the waveform of the output of the surge voltage generator, and the value of the coupling capacitor has little effect on the voltage waveform of the sample. Simulation results show that surge capacitor DC and impulse superimposed aging test is feasible.