In addition to typical indoor and outdoor spaces, there are numerous transitional spaces in a building that are unlike indoor and outdoor spaces, where most people spend time for entertainment. There is a need to investigate the comparison between these three types of spaces, including indoor spaces, transitional spaces and outdoor spaces. In this study, the thermal responses and thermal environmental parameters of the indoor, outdoor and transitional spaces were simultaneously recorded. Values of standard effective temperature (SET*), physiologically equivalent temperature (PET) and universal thermal climate index (UTCI) were calculated, and relationships between mean thermal sensation vote (MTSV), SET*, PET and UTCI were also analysed. The results indicate that the air velocity fluctuation and mean radiant temperature of the outdoor space were more significant than those of other two spaces. The neutral thermal indices of the outdoor space were higher than those of the indoor and transitional spaces. Additionally, regression models between MTSV and thermal indices (SET*, PET and UTCI) were analysed. There are strong linear relationships between MTSV and SET* in all spaces. The linear relationships between MTSV were significant when compared with PET and UTCI. Thus, the adaption of thermal indices for evaluation of different spaces must be considered.
A post-occupancy study of the thermal environment and thermal comfort in office buildings certified with China’s one- to three-star green building label was compared with traditional office buildings. The results showed that the indoor temperature and air movement of both building types met the GB/T 50378, Green Building Evaluation Standard. The green office buildings outperformed conventional office buildings, and occupants had a more comfortable thermal perception and a higher satisfaction level. The three-star buildings were shown to produce the best performance. The comfort temperature range of office workers in green office buildings was about 4°C. The wider comfort temperature range suggests that employees in green office buildings are better adapted to their thermal environment and may have greater potential for energy savings in the design and intelligent operation of air-conditioning systems. The purpose of this study is to gain a more comprehensive understanding of the indoor conditions of green office buildings in China, which may have implications for design decisions on green building practices, and provide guidance for the design and operation of green buildings that can create a better indoor environment with better energy consumption and carbon emission while ensuring indoor thermal comfort.
Owing to historical reasons, only a few locations in the Guangdong province use heating to enhance interior thermal conditions. With the variation in climate and increase in people’s lifestyle requirements, winter heating has become increasingly necessary. However, a literature review revealed that only a few studies have investigated the heating requirements during winter in the Guangdong province. In this study, we compared the thermal comfort of radiant floor heating with wall-mounted air conditioner heating. A Guangzhou University climate chamber was used in several investigations. The findings revealed that the thermal neutral temperatures of radiant heating and air conditioner heating were 22.0 °C and 23.0 °C, respectively, about 1 °C variation in temperature. Additionally, in the research on thermal reactions and local skin temperature measurements, the impact of local thermal discomfort on the overall thermal experience was also considered. The findings showed a direct relationship between the local thermal discomfort caused by radiant heating and general thermal sensation. Thermal sensation of the subjects mainly originated from the lower extremities and was significantly affected by Va (air velocity). The relationship between the local thermal discomfort of convective heating and general thermal sensation was weak and mainly caused by the uneven thermal environment. Thus, in south China, for lowering energy usage, radiant floor heating should be used to create an improved indoor thermal environment in winter.
In this study, on-site measurements of the summer air-conditioning environment in obstetric clinics of six hospitals in Guangzhou, China, and subjective questionnaire surveys of pregnant women regarding hot and humid environments were carried out. A total of 723 valid questionnaires were obtained. In order to determine the appropriate metabolic rate, three methods were used in this study to obtain three different metabolic rate values, including ASHRAE 55-2020 for healthy adults in a sedentary state 1.0 met, pregnant women after 5 months of pregnancy 1.2 met based on medical tests and the resting metabolic rate of pregnant women 0.66 met. Linear fitting was performed with three predicted mean votes (PMVs) and thermal sensation vote (TSV). The mean TSV (MTSV) and PMV models were established to estimate the actual thermal neutral value (25.3°C) and the predicted thermal neutral value (26.1°C) for pregnant women. The PMV model for pregnant women was linearly corrected, and the corrected PMV model coincided with the actual thermal sensory MTSV model. The corrected PMV estimate was 0.60 PMV + 0.17, and the corrected thermal neutral estimate was 25.3°C. Finally, a simplified model of the relationship between the PMV for pregnant women and the relative humidity, mean radiant temperature, wind speed and air temperature was obtained.