Lin Chen

Dr. Lin Chen


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
XLXiuying Luo
Xiuying Luo
XWXiaoying Wu
Xiaoying Wu
LCLin Chen
Lin Chen
YZYun Zhao
Yun Zhao
LZLi Zhang
Li Zhang
WHWensheng Hou
Wensheng Hou
Currently, surface electromyography (sEMG) features of the forearm multi-tendon muscles are widely used in gesture recognition, however, there are few investigations on the inherent physiological mechanism of muscle synergies. We aimed to study whether the muscle synergies could be used for gesture recognition. Five healthy participants executed five gestures of daily life (pinch, fist, open hand, grip, and extension) and the sEMG activity was acquired from six forearm muscles. A non-negative matrix factorization (NMF) algorithm was employed to decompose the pre-treated six-channel sEMG data to obtain the muscle synergy matrixes, in which the weights of each muscle channel determined the feature set for hand gesture classification. The results showed that the synergistic features of forearm muscles could be successfully clustered in the feature space, which enabled hand gestures to be recognized with high efficiency. By augmenting the number of participants, the mean recognition rate remained at more than 96% and reflected high robustness. We showed that muscle synergies can be well applied to gesture recognition.

1 April 2021 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
LWLi Wang
Li Wang
DXDi Xiao
Di Xiao
WHWen S. Hou
Wen S. Hou
XWXiao Y. Wu
Xiao Y. Wu
LCLin Chen
Lin Chen

11 September 2020 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
LWLi Wang
Li Wang
DXDi Xiao
Di Xiao
WHWen S. Hou
Wen S. Hou
XWXiao Y. Wu
Xiao Y. Wu
LCLin Chen
Lin Chen
The magnetic resonance (MR) images are acknowledged to be inevitably corrupted by Rician distributed noise, which adversely affected the image quality for diagnosis purpose. However, the traditional denoising methods may recover the images from corruptions with severe loss of detailed structure and edge information, which would affect the lesion detections and diagnostic decision making. In this study, we challenged improving the Rician noise removal from three-dimensional (3D) MR volumetric data through a modified higher-order singular value decomposition (MHOSVD) method. The proposed framework of MHOSVD involved a parameterized logarithmic nonconvex penalty function for low-rank tensor approximation (LRTA) algorithm optimization to suppress the image noise in MR dataset. Reference cubes were extracted from the noisy image volume, and block matching was performed according to nonlocal similarity for a fourth-order tensor construction. Then the LRTA problem was implemented by tensor factorization approaches, and the ranks of unfolding matrices along different modes of the tensor were estimated utilizing an adaptive nonconvex low-rank method. The denoised MR images were finally restored through aggregating all recovered cubes. We investigated the proposed algorithm MHOSVD on both the synthetic and real clinic 3D MR images for Rician noise removal, and relative results demonstrated that the MHOSVD can recover images with fine structures and detailed edge preservation with heavy noise even as high as 15% of the maximum intensity. The experimental results were also compared along with several classical denoising methods; the MHOSVD exhibited a sufficient improvement in noise-removal performance at various noise conditions in terms of different measurement indices such as peak signal-to-noise ratio and structural similarity index metrics. Based upon the comparison, the proposed MHOSVD has proved a relative state-of-the-art performance with excellent detailed structure reservation.

1 March 2024 in Physiological Measurement
Verified
Journal Article
Open access
LYLiqing Yang
Liqing Yang
ZDZhimei Ding
Zhimei Ding
JZJiangjie Zhou
Jiangjie Zhou
SZSiyuan Zhang
Siyuan Zhang
QWQi Wang
Qi Wang
LCLin Chen
Lin Chen
Background and Objective . Sleep-disordered breathing (SDB) poses health risks linked to hypertension, cardiovascular disease, and diabetes. However, the time-consuming and costly standard diagnostic method, polysomnography (PSG), limits its wide adoption and leads to underdiagnosis. To tackle this, cost-effective algorithms using single-lead signals (like respiratory, blood oxygen, and electrocardiogram) have emerged. Despite respiratory signals being preferred for SDB assessment, a lack of comprehensive reviews addressing their algorithmic scope and performance persists. This paper systematically reviews 2012–2022 literature, covering signal sources, processing, feature extraction, classification, and application, aiming to bridge this gap and provide future research references. Methods . This systematic review followed the registered PROSPERO protocol (CRD42022385130), initially screening 342 papers, with 32 studies meeting data extraction criteria. Results . Respiratory signal sources include nasal airflow (NAF), oronasal airflow (OAF), and respiratory movement-related signals such as thoracic respiratory effort (TRE) and abdominal respiratory effort (ARE). Classification techniques include threshold rule-based methods (8), machine learning models (13), and deep learning models (11). The NAF-based algorithm achieved the highest average accuracy at 94.11%, surpassing 78.19% for other signals. Hypopnea detection sensitivity with single-source respiratory signals remained modest, peaking at 73.34%. The TRE and ARE signals proved to be reliable in identifying different types of SDB because distinct respiratory disorders exhibited different patterns of chest and abdominal motion. Conclusions . Multiple detection algorithms have been widely applied for SDB detection, and their accuracy is closely related to factors such as signal source, signal processing, feature selection, and model selection.

29 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZYZHAO Yin
ZHAO Yin
STShangjie Tang
Shangjie Tang
XWXiaoying Wu
Xiaoying Wu
QFQiang Fu
Qiang Fu
XFXingyu Fan
Xingyu Fan
WHWensheng Hou
Wensheng Hou
The study aims to explore the spatial distribution of multi-tendinous muscle modulated by central nervous system (CNS) during sustained contraction. Nine subjects were recruited to trace constant target forces with right index finger extension. Surface electromyography (sEMG) of extensor digitorum (ED) were recorded with a 32-channel electrode array. Nine successive topographic maps (TM) were obtained. Pixel wise analysis was utilized to extract subtracted topographic maps (STM), which exhibited inhomogeneous distribution. STMs were characterized into hot, warm, and cool regions corresponding to higher, moderate, and lower change ranges, respectively. The relative normalized area (normalized to the first phase) of these regions demonstrated different changing trends as rising, plateauing, and falling over time, respectively. Moreover, the duration of these trends were found to be affected by force level. The rising/falling periods were longer at lower force levels, while the plateau can be achieved from the initial phase for higher force output (45% maximal voluntary contraction). The results suggested muscle activity reorganization in ED plays a role to maintain sustained contraction. Furthermore, the decreased dynamical regulation ability to spatial reorganization may be prone to induce fatigue. This finding implied that spatial reorganization of muscle activity as a regulation mechanism contribute to maintain constant force production.

1 January 2025 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
GWGuangfei Wu
Guangfei Wu
WGWenqing Gu
Wenqing Gu
YLYi Luo
Yi Luo
XZXin Zhang
Xin Zhang
LLLei Li
Lei Li
XWXing Wang
Xing Wang
Sensory substitution technologies represent a significant advancement in modern prosthetics, with hybrid tactile feedback approaches gaining increasing attention. However, limited studies have examined the role of hybrid tactile feedback in closed-loop prosthetic control, particularly in relation to varying visual conditions. This study employed a 2-factor mixed design involving 10 able-bodied participants and 3 transradial amputees. Three visual conditions--Optimal Vision, Limited Vision, and Blocked Vision were tested. Participants performed prosthetic wrist and hand position-matching tasks utilizing vibrotactile, electrotactile, and hybrid vibro-electrotactile (HyVE) feedback modes provided by a custom-developed prosthetic position feedback control system. Outcome measures included categorical analysis of task completion outcomes, control precision error (CPE), completion time (CT), and feedback preference. The HyVE feedback mode elevated success rates across all visual conditions, while effectively reducing the incidence of errors and confusion trials. Compared to electrotactile mode, HyVE yielded significantly lower CPE, and compared to vibrotactile mode, it enabled significantly shorter CT. Furthermore, 7 out of 13 participants (>50%) selected HyVE as their preferred feedback mode. The proposed HyVE tactile feedback method effectively combines the advantages of electrotactile and vibrotactile stimulation, mitigating their respective limitations. It enables accurate perception of prosthetic motion without the need for continuous visual monitoring, showing significant potential for enhancing everyday prosthetic functionality.