Alex Valenzuela

Mr. Alex Valenzuela

Universidad Politécnica Salesiana
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2019 in Energies
Verified
Journal Article
Open access
PDF file
Alex ValenzuelaAlex Valenzuela
Alex Valenzuela
Esteban IngaEsteban Inga
Esteban Inga
Silvio SimaniSilvio Simani
Silvio Simani
This study describes a practical methodology for a resilient planning and routing of power distribution networks considering real scenarios based on georeferenced data. Customers’ demand and their location are the basis for distribution transformer allocation considering the minimal construction costs and reduction of utility’s budget. MST (Minimum Spanning Tree) techniques are implemented to determine the optimal location of distribution transformers and Medium voltage network routing. Additionally, the allocation of tie points is determined to minimise the total load shedding when unusual and extreme events are faced by the distribution grid, improving reliability and resilience reducing downtime during those events. The proposed methodology provides a coverage of 100%, supplying electricity to the totality of customers within statutory limits during normal and unusual conditions.

25 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
Alex ValenzuelaAlex Valenzuela
Alex Valenzuela
IMIván Montalvo
Iván Montalvo
Esteban IngaEsteban Inga
Esteban Inga
Designing and planning of electrical distribution systems is a task that design engineers perform during their daily activities. These designs, which are completed manually, are made according to the expertise of the designer; as a consequence, the obtained product varies depending on the person in charge of executing the layout, highlighting the fact that those designs are susceptible to involuntary human mistakes resulting in no optimal solutions and high cost consequences. The work presented below explains the implementation of an intelligent decision tool that allows the design of network distribution system planning considering the current electrical company standards, in order to have a clear and quick initial overview of the configuration that an electricity network should have in response to an increasing demand, considering not only the coverage and capacity of the transformers but also voltage drop along the conductors, which must not exceed 3% of the nominal value. The objective of this design tool is that it can be applicable in real scenarios; for this reason, the routing of the conductors and the location of the transformers are based on a georeferenced map. It is important to mention that the optimization problem is focused on minimizing the amount of transformers and at the same time ensuring a total coverge of 100% end users connected to the grid. This tool would be very useful in the educational and practical fields, since private and public electricity companies could use it to obtain a quick and efficient base product on which they could start to develop expansion and planning of distribution networks. The concept and development of such a tool is the subject of this paper.

2 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
Alex ValenzuelaAlex Valenzuela
Alex Valenzuela
Silvio SimaniSilvio Simani
Silvio Simani
Esteban IngaEsteban Inga
Esteban Inga
Electrical power systems represent a fundamental part of society, and their efficient operations are of vital importance for social and economic development. Power systems have been designed to withstand interruptions under already provided safety and quality principles; however, there are some extreme and not so frequent events that could represent inconveniences for the correct operation of the entire system. For this reason, in recent years the term resilience, which serves to describe the capacity of a system to recover from an unwanted event, has been analyzed on planning, operation and remedial actions. This work is focused on the implementation of a topological reconfiguration tool, which is oriented to change the structure of primary feeders based on changing the status of switchgears. Once the distribution network has been reconfigured, an algorithm of protection coordination is executed based on communication peer-to-peer between Matlab and PowerFactory, which develops an adaptive calculation to determine the current setting and the time multiplier setting. The reconfiguration and coordination protection algorithms could be implemented and evaluated on different distribution networks, areas and locations.

15 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
AGAlex Guamán
Alex Guamán
Alex ValenzuelaAlex Valenzuela
Alex Valenzuela
The distribution network is the most exposed part of the electrical power system relative to different abnormal events; therefore, it reports the highest occurrence rates in terms of electrical and mechanical failures. The present project describes a strategy for restoring faulty areas after the occurrence of an abnormal event causing an outage; consequently, the proposed algorithm is not only focused on the maximization of the connected loads but also deals with the minimization of the switching operations by considering technical operational constraints. The remarked study has two stages: The first one finds an initial set of tie-line candidates using the spanning tree technique, while the second stage applies a genetic algorithm to determine the optimal solution considering all the constraints. Three cases studies have been used to test the proposed algorithm, then the simulation and results of IEEE 13, 37 and 94 node feeders depict the effectiveness of the restoration strategy.

13 October 2020
Verified
Conference Paper
Closed access
FRFausto Ruiz-Tipan
Fausto Ruiz-Tipan
Carlos Barrera-SingañaCarlos Barrera-Singaña
Carlos Barrera-Singaña
Alex ValenzuelaAlex Valenzuela
Alex Valenzuela
Voltage control is a major factor that requires constant analysis to avoid the collapse of transmission systems. The methodologies related to voltage control could be defined as static and dynamic. The present research focuses on static methods, these methods expose expose the difficulty of providing remarkable data for parallel reactive compensation when are applied individually. However, it has been possible to relate the sensitivity VQ and the QV curve to overcome this difficulty. The VQ sensitivity uses diagonal elements of the inverse matrix of the reduced Jacobian matrix, so that the methodology mentioned determines the weakest bar in the power system. On the other hand, the QV curve indicates the robustness of the system in terms of its reactive power margin (RPM). The proposed methodology determines the weakest bus and the amount of parallel reactive power required to compensate and operate within adequate voltage profiles. This provides primary information associated to the safety of the voltage used by planning and operation areas. the proposed methodology is performed in MatLab, and it is applied to the IEEE 57-busbar system considering two cases, initial and a random contingency conditions.

1 September 2017
Verified
Conference Paper
Closed access
Alex ValenzuelaAlex Valenzuela
Alex Valenzuela
IMIván Montalvo
Iván Montalvo
Carlos Barrera-SingañaCarlos Barrera-Singaña
Carlos Barrera-Singaña
Daily Internal Combustion Engine vehicles consume enormous amounts of petroleum derivatives, as a result, the environmental degradation has increased in the current industrialized world. Set in this context, some global initiatives are concerned not only about the decarbonisation of the transport sector but also the proliferation of renewable energies, which have been main factors that have impulse the development of electrical vehicle technologies. This paper proposes a comprehensive approach of benefits and challenges of electric vehicle penetration in Ecuadorian's grids, considering different charging points and strategies, state of charge of electric vehicles, distributed generation and vehicle to grid concept for commercial and residential customers located in a profitable sector of Quito city. Results depict that electric vehicles together with distributed generation could enhance the overall system efficiency operation; however, some politic and technical requirements are needed to achieve this total integration.