Carole Hayakawa

Carole Hayakawa

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2007 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
ISInSeok Seo
InSeok Seo
JYJoon S. You
Joon S. You
CHCarole Hayakawa
Carole Hayakawa
VVVasan Venugopalan
Vasan Venugopalan
The use of perturbation and differential Monte Carlo (pMC/dMC) methods in conjunction with nonlinear optimization algorithms were proposed recently as a means to solve inverse photon migration problems in regionwise heterogeneous turbid media. We demonstrate the application of pMC/dMC methods for the recovery of optical properties in a two-layer extended epithelial tissue model from experimental measurements of spatially resolved diffuse reflectance. The results demonstrate that pMC/dMC methods provide a rapid and accurate approach to solve two-region inverse photon migration problems in the transport regime, that is, on spatial scales smaller than a transport mean free path and in media where optical scattering need not dominate absorption. The pMC/dMC approach is found to be effective over a broad range of absorption (50 to 400%) and scattering (70 to 130%) perturbations. The recovery of optical properties from spatially resolved diffuse reflectance measurements is examined for different sets of source-detector separation. These results provide some guidance for the design of compact fiber-based probes to determine and isolate optical properties from both epithelial and stromal layers of superficial tissues.

12 April 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CHCarole Hayakawa
Carole Hayakawa
LMLisa Malenfant
Lisa Malenfant
JRJanaka C. Ranasinghesagara
Janaka C. Ranasinghesagara
DCDavid J. Cuccia
David J. Cuccia
JSJerome Spanier
Jerome Spanier
VVVasan Venugopalan
Vasan Venugopalan
Monte Carlo (MC) methods to provide solutions for the radiative transport equation (RTE) originated at Los Alamos National Lab in 1946. At that time, the intent was to solve nuclear fission problems. The initial code base that was developed has subsequently evolved into the Monte Carlo N-Particle Transport (MCNP1) code.2 Since then, MC simulations of radiative transport have been used to solve problems in biomedical optics. The first paper documenting the use of MC to study light propagation in tissue was published by Wilson and Adam,3 and this was followed by Prahl et al.4 which served as a precursor to the seminal 1995 paper by Wang et al.5 that introduced the open-source MC Command Line application (MCML) code commemorated in this special issue.

20 January 2014 in Journal of the Optical Society of America A
Verified
Journal Article
Open access
PDF file
CHCarole Hayakawa
Carole Hayakawa
JSJerome Spanier
Jerome Spanier
VVVasan Venugopalan
Vasan Venugopalan
We examine the relative error of Monte Carlo simulations of radiative transport that employ two commonly used estimators that account for absorption differently, either discretely, at interaction points, or continuously, between interaction points. We provide a rigorous derivation of these discrete and continuous absorption weighting estimators within a stochastic model that we show to be equivalent to an analytic model, based on the radiative transport equation (RTE). We establish that both absorption weighting estimators are unbiased and, therefore, converge to the solution of the RTE. An analysis of spatially resolved reflectance predictions provided by these two estimators reveals no advantage to either in cases of highly scattering and highly anisotropic media. However, for moderate to highly absorbing media or isotropically scattering media, the discrete estimator provides smaller errors at proximal source locations while the continuous estimator provides smaller errors at distal locations. The origin of these differing variance characteristics can be understood through examination of the distribution of exiting photon weights.

1 January 2009 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
STSheng-Hao Tseng
Sheng-Hao Tseng
CHCarole Hayakawa
Carole Hayakawa
JSJerome Spanier
Jerome Spanier
ADAnthony J. Durkin
Anthony J. Durkin
We design a special diffusing probe to investigate the optical properties of human skin in vivo. The special geometry of the probe enables a modified two-layer (MTL) diffusion model to precisely describe the photon transport even when the source-detector separation is shorter than 3 mean free paths. We provide a frequency domain comparison between the Monte Carlo model and the diffusion model in both the MTL geometry and conventional semiinfinite geometry. We show that using the Monte Carlo model as a benchmark method, the MTL diffusion theory performs better than the diffusion theory in the semiinfinite geometry. In addition, we carry out Monte Carlo simulations with the goal of investigating the dependence of the interrogation depth of this probe on several parameters including source-detector separation, sample optical properties, and properties of the diffusing high-scattering layer. From the simulations, we find that the optical properties of samples modulate the interrogation volume greatly, and the source-detector separation and the thickness of the diffusing layer are the two dominant probe parameters that impact the interrogation volume. Our simulation results provide design guidelines for a MTL geometry probe.

1 June 2014 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
AGAdam R. Gardner
Adam R. Gardner
CHCarole Hayakawa
Carole Hayakawa
VVVasan Venugopalan
Vasan Venugopalan
We present a coupled forward-adjoint Monte Carlo (cFAMC) method to determine the spatially resolved sensitivity distributions produced by optical interrogation of three-dimensional (3-D) tissue volumes. We develop a general computational framework that computes the spatial and angular distributions of the forward-adjoint light fields to provide accurate computations in mesoscopic tissue volumes. We provide full computational details of the cFAMC method and provide results for low- and high-scattering tissues probed using a single pair of optical fibers. We examine the effects of source-detector separation and orientation on the sensitivity distributions and consider how the degree of angular discretization used in the 3-D tissue model impacts the accuracy of the resulting absorption sensitivity profiles. We discuss the value of such computations for optical imaging and the design of optical measurements.