Beata Morawiec

Dr. Beata Morawiec

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in JACC
Verified
Journal Article
Closed access
RTRaphael Twerenbold
Raphael Twerenbold
JNJohannes Tobias Neumann
Johannes Tobias Neumann
NSNils Arne Sörensen
Nils Arne Sörensen
FOFrancisco Ojeda
Francisco Ojeda
MKMahir Karakas
Mahir Karakas
CMChristian Mueller
Christian Mueller

30 January 2018 in Circulation
Verified
Journal Article
Open access
PDF file
RTRaphael Twerenbold
Raphael Twerenbold
PBPatrick Badertscher
Patrick Badertscher
JBJasper Boeddinghaus
Jasper Boeddinghaus
TNThomas Nestelberger
Thomas Nestelberger
WKWildi Karin
Wildi Karin
CMChristian Müller
Christian Müller
Background: The European Society of Cardiology recommends a 0/1-hour algorithm for rapid rule-out and rule-in of non–ST-segment elevation myocardial infarction using high-sensitivity cardiac troponin (hs-cTn) concentrations irrespective of renal function. Because patients with renal dysfunction (RD) frequently present with increased hs-cTn concentrations even in the absence of non–ST-segment elevation myocardial infarction, concern has been raised regarding the performance of the 0/1-hour algorithm in RD. Methods: In a prospective multicenter diagnostic study enrolling unselected patients presenting with suspected non–ST-segment elevation myocardial infarction to the emergency department, we assessed the diagnostic performance of the European Society of Cardiology 0/1-hour algorithm using hs-cTnT and hs-cTnI in patients with RD, defined as an estimated glomerular filtration rate <60 mL/min/1.73 m 2 , and compared it to patients with normal renal function. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including cardiac imaging. Safety was quantified as sensitivity in the rule-out zone, accuracy as the specificity in the rule-in zone, and efficacy as the proportion of the overall cohort assigned to either rule-out or rule-in based on the 0- and 1-hour sample. Results: Among 3254 patients, RD was present in 487 patients (15%). The prevalence of non–ST-segment elevation myocardial infarction was substantially higher in patients with RD compared with patients with normal renal function (31% versus 13%, P <0.001). Using hs-cTnT, patients with RD had comparable sensitivity of rule-out (100.0% [95% confidence interval {CI}, 97.6–100.0] versus 99.2% [95% CI, 97.6–99.8]; P =0.559), lower specificity of rule-in (88.7% [95% CI, 84.8–91.9] versus 96.5% [95% CI, 95.7–97.2]; P <0.001), and lower overall efficacy (51% versus 81%, P <0.001), mainly driven by a much lower percentage of patients eligible for rule-out (18% versus 68%, P <0.001) compared with patients with normal renal function. Using hs-cTnI, patients with RD had comparable sensitivity of rule-out (98.6% [95% CI, 95.0–99.8] versus 98.5% [95% CI, 96.5–99.5]; P =1.0), lower specificity of rule-in (84.4% [95% CI, 79.9–88.3] versus 91.7% [95% CI, 90.5–92.9]; P <0.001), and lower overall efficacy (54% versus 76%, P <0.001; proportion ruled out, 18% versus 58%, P <0.001) compared with patients with normal renal function. Conclusions: In patients with RD, the safety of the European Society of Cardiology 0/1-hour algorithm is high, but specificity of rule-in and overall efficacy are decreased. Modifications of the rule-in and rule-out thresholds did not improve the safety or overall efficacy of the 0/1-hour algorithm. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00470587.

25 April 2017 in Circulation
Verified
Journal Article
Closed access
PDF file
JBJasper Boeddinghaus
Jasper Boeddinghaus
TNThomas Nestelberger
Thomas Nestelberger
RTRaphael Twerenbold
Raphael Twerenbold
WKWildi Karin
Wildi Karin
PBPatrick Badertscher
Patrick Badertscher
CMChristian Müller
Christian Müller
Background: Four strategies for very early rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I (hs-cTnI) have been identified. It remains unclear which strategy is most attractive for clinical application. Methods: We prospectively enrolled unselected patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction. The final diagnosis was adjudicated by 2 independent cardiologists. Hs-cTnI levels were measured at presentation and after 1 hour in a blinded fashion. We directly compared all 4 hs-cTnI–based rule-out strategies: limit of detection (LOD, hs-cTnI<2 ng/L), single cutoff (hs-cTnI<5 ng/L), 1-hour algorithm (hs-cTnI<5 ng/L and 1-hour change<2 ng/L), and the 0/1-hour algorithm recommended in the European Society of Cardiology guideline combining LOD and 1-hour algorithm. Results: Among 2828 enrolled patients, acute myocardial infarction was the final diagnosis in 451 (16%) patients. The LOD approach ruled out 453 patients (16%) with a sensitivity of 100% (95% confidence interval [CI], 99.2%–100%), the single cutoff 1516 patients (54%) with a sensitivity of 97.1% (95% CI, 95.1%–98.3%), the 1-hour algorithm 1459 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%–99.2%), and the 0/1-hour algorithm 1463 patients (52%) with a sensitivity of 98.4% (95% CI, 96.8%–99.2%). Predefined subgroup analysis in early presenters (≤2 hours) revealed significantly lower sensitivity (94.2%, interaction P =0.03) of the single cutoff, but not the other strategies. Two-year survival was 100% with LOD and 98.1% with the other strategies ( P <0.01 for LOD versus each of the other strategies). Conclusions: All 4 rule-out strategies balance effectiveness and safety equally well. The single cutoff should not be applied in early presenters, whereas the 3 other strategies seem to perform well in this challenging subgroup. Clinical Trial Registration: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00470587.

1 September 2018 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
JBJasper Boeddinghaus
Jasper Boeddinghaus
RTRaphael Twerenbold
Raphael Twerenbold
TNThomas Nestelberger
Thomas Nestelberger
PBPatrick Badertscher
Patrick Badertscher
WKWildi Karin
Wildi Karin
JPJiri Parenica
Jiri Parenica
BACKGROUND: Clinical performance of the novel high-sensitivity cardiac troponin I (Siemens-hs-cTnI-Centaur) assay is unknown. We aimed to clinically validate the Siemens-hs-cTnI-Centaur assay and develop 0/1-h and 0/2-h algorithms. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists including all clinical information twice: first, using serial hs-cTnT (Roche-Elecsys, primary analysis); second, using hs-cTnI (Abbott-Architect, secondary analysis) measurements in addition to the clinically applied (hs)-cTn. Siemens-hs-cTnI-Centaur was measured at presentation, 1 h, and 2 h. The primary objective was a direct comparison of diagnostic accuracy, quantified by the area under the ROC curve (AUC), of Siemens-hs-cTnI-Centaur vs the 2 established hs-cTn assays (Roche-hs-cTnT-Elecsys, Abbott-hs-cTnI-Architect). Secondary objectives included the development of Siemens-hs-cTnI-Centaur-specific 0/1-h and 0/2-h algorithms. RESULTS: AMI was the final diagnosis in 318 of 1755 (18%) patients (using Roche-hs-cTnT-Elecsys for adjudication). The AUC at presentation for Siemens-hs-cTnI-Centaur was 0.94 (95% CI, 0.92–0.96) and comparable with 0.95 (95% CI, 0.93–0.97) for Roche-hs-cTnT-Elecsys and 0.93 (95% CI, 0.90–0.96) for Abbott-hs-cTnI-Architect. Applying the derived Siemens-hs-cTnI-Centaur 0/1-h algorithm to the validation cohort, 46% of patients were ruled out (sensitivity, 99.1%; 95% CI, 95.3–100), and 18% of patients were ruled in (specificity, 94.1%; 95% CI, 91.8–95.9). The Siemens-hs-cTnI-Centaur 0/2-h algorithm ruled out 55% of patients (sensitivity, 100%; 95% CI, 94.1–100), and ruled in 18% of patients (specificity, 96.0%; 95% CI, 93.1–97.9). Findings were confirmed in the secondary analyses using serial measurements of Abbott-hs-cTnI-Architect for adjudication. CONCLUSIONS: Diagnostic accuracy and clinical utility of the novel Siemens-hs-cTnI-Centaur assay are high and comparable with the established hs-cTn assays. ClinicalTrials.gov Identifier: NCT00470587

1 September 2017 in JACC
Verified
Journal Article
Closed access
TNThomas Nestelberger
Thomas Nestelberger
JBJasper Boeddinghaus
Jasper Boeddinghaus
PBPatrick Badertscher
Patrick Badertscher
RTRaphael Twerenbold
Raphael Twerenbold
WKWildi Karin
Wildi Karin
ABAndreas Buser
Andreas Buser

29 August 2018 in European Heart Journal
Verified
Journal Article
Closed access
JBJasper Boeddinghaus
Jasper Boeddinghaus
TNThomas Nestelberger
Thomas Nestelberger
RTRaphael Twerenbold
Raphael Twerenbold
JNJohannes Tobias Neumann
Johannes Tobias Neumann
BLBertil Lindahl
Bertil Lindahl
PDPeter Dilba
Peter Dilba
We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific to older patients. We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age [<55 years (young), ≥55 to <70 years (middle-age), ≥70 years (old)]. Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% [95% confidence interval (95% CI) 94.9-100] in young, 99.3% (95% CI 96.0-99.9) in middle-age, and 99.3% (95% CI 97.5-99.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8-97.9) in young, 96.1% (95% CI 94.5-97.2) in middle-age, and 92.7% (95% CI 90.7-94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P < 0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P < 0.01), reduced overall efficacy for hs-cTnT (P < 0.01), while maintaining efficacy for hs-cTnI. Findings were confirmed in two validation cohorts (n = 2767). While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnI. https://clinicaltrials.gov/ct2/show/NCT00470587, number NCT00470587 and NCT02355457 (BACC).