This study investigated the relationship between pain sensitivity, adaptability, and potency of endogenous pain inhibition, including conditioned pain modulation (CPM) and local pain inhibition. Forty-one healthy volunteers (20 male, 21 female) received conditioning stimulation (CS) over 2 sessions in a random order: tonic heat pain (46 °C) on the right leg for 7 minutes and cold pressor pain (1 °C to 4 °C) on the left hand for 5 minutes. Participants rated the intensity of pain continuously using a 0 to 10 electronic visual analogue scale. The primary outcome measures were pressure pain thresholds (PPT) measured at the heterotopic and homotopic location to the CS sites before, during, and 20 minutes after CS. Two groups of participants, pain adaptive and pain nonadaptive, were identified based on their response to pain in the cold pressor test. Pain-adaptive participants showed a pain reduction between peak pain and pain at end of the test by at least 2 of 10 (n=16); whereas the pain-nonadaptive participants reported unchanged peak pain during 5-minute CS (n=25). Heterotopic PPTs during the CS did not differ between the 2 groups. However, increased homotopic PPTs measured 20 minutes after CS correlated with the amount of pain reduction during CS. These results suggest that individual sensitivity and adaptability to pain does not correlate with the potency of CPM. Adaptability to pain is associated with longer-lasting local pain inhibition.
Study objectives: To investigate whether electroencephalographic (EEG) activities during non-rapid eye movement sleep stage 3 (N3) in obstructive sleep apnea syndrome (OSAS) patients were changed with continuous positive airway pressure (CPAP) treatment. Methods: A cross-sectional study of EEG activity during N3 sleep was conducted in 15 patients with moderate to severe OSAS without and with CPAP treatment compared to 15 normal controls. The amplitude, and absolute and relative power of delta, theta, alpha and beta waves as well as the absolute power ratio of slow to fast EEG waves (i.e., absolute power of delta and theta waves/absolute power of alpha and beta waves) and the spectral power density of 0-30 Hz EEG activities were analyzed. Results: CPAP significantly increased N3 sleep, the absolute and relative powers, amplitudes of delta and theta waves, and absolute power ratio of slow to fast EEG waves, but decreased relative alpha and beta powers during N3 sleep. However, there were no significant differences in those parameters between the OSAS patients with CPAP treatment and normal controls. Conclusions: CPAP prolongs N3 sleep and increases the power and amplitude of slow EEG waves during N3 sleep, which indicates an improvement in sleep quality and further provides evidence for recommendation of CPAP treatment for OSAS patients.